Utility of neurophysiological monitoring using dorsal column mapping in intramedullary spinal cord surgery Clinical article

被引:42
|
作者
Yanni, Daniel S. [1 ]
Ulkatan, Sedat [2 ]
Deletis, Vedran [2 ]
Barrenechea, Ignacio J. [1 ]
Sen, Chandranath [1 ]
Perin, Noel I. [1 ]
机构
[1] St Lukes Roosevelt Hosp, Dept Neurol Surg, New York, NY 10019 USA
[2] St Lukes Roosevelt Hosp, Div Neurophysiol, New York, NY 10019 USA
关键词
intramedullary spinal tumor; neurophysiological monitoring; intraoperative mapping; somatosensory evoked potentials; motor evoked potentials; dorsal column mapping; TUMORS; EPENDYMOMAS; MANAGEMENT; RESECTION;
D O I
10.3171/2010.1.SPINE09112
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Intramedullary spinal cord tumors can displace the surrounding neural tissue, causing enlargement and distortion of the normal cord anatomy. Resection requires a midline myelotomy to avoid injury to the posterior columns. Locating the midline for myelotomy is often difficult because of the distorted anatomy. Standard anatomical landmarks may be misleading in patients with intramedullary spinal cord tumors due to cord rotation, edema, neovascularization, or local scar formation. Misplacement of the myelotomy places the posterior columns at risk of significant postoperative disability. The authors describe a technique for mapping the dorsal column to accurately locate the midline. Methods. A group of 10 patients with cervical and thoracic intramedullary spinal cord lesions underwent dorsal column mapping in which a strip electrode was used to define the midline. After the laminectomy and durotomy, a custom-designed multielectrode grid was placed on the exposed dorsal surface of the spinal cord. The electrode is made up of 8 parallel Teflon-coated stainless-steel wires (76-mu m diameter, spaced I mm apart) embedded in silastic with each of the wires stripped of its insulating coating along a length of 2 mm. This strip electrode maps the amplitude gradient of conducted spinal somatosensory evoked potentials elicited by bilateral tibial nerve stimulation. Using these recordings, the dorsal columns are topographically mapped as lying between two adjacent numbers. Results. The authors conducted a retrospective analysis of the preoperative, immediate, and short-term postoperative neurological status, focusing especially on posterior column function. There were 8 women and 2 men whose mean age was 52 years. There were 4 ependymomas, 1 subependymoma,1 gangliocytoma, 1 anaplastic astrocytoma, 1 cavernous malformation, and 2 symptomatic syringes requiring shunting. In all patients the authors attempted to identify the midline by using anatomical landmarks, and then proceeded with dorsal column mapping to identify the midline electrophysiologically. In the 2 patients with syringomyelia and in 5 of the patients with tumors, the authors were unable to identify the midline anatomically with any certainty. In 2 patients with intramedullary tumors, they were able to identify the midline anatomically with certainty. Dorsal column mapping allowed identification of the midline and to confirm the authors' anatomical localization. In 2 patients with intramedullary tumors, posterior column function was preserved only on I side. All other patients had intact posterior column function preoperatively. Conclusions. Dorsal column mapping is a useful technique for guiding the surgeon in locating the midline for myelotomy in intramedullary spinal cord surgery. In conjunction with somatosensory evoked potential, motor evoked potential, and D-wave recordings, we have been able to reduce the surgical morbidity related to dorsal column dysfunction in this small group of patients. (DOL 10.3171/2010.1.SPINE09112)
引用
收藏
页码:623 / 628
页数:6
相关论文
共 50 条
  • [1] Dorsal Column Mapping for Intramedullary Spinal Cord Tumor Resection Decreases Dorsal Column Dysfunction
    Mehta, Ankit Indravadan
    Mohrhaus, Cindy A.
    Husain, Aatif M.
    Karikari, Isaac O.
    Hughes, Betsy
    Hodges, Tiffany
    Gottfried, Oren
    Bagley, Carlos A.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2012, 25 (04): : 205 - 209
  • [2] Neurophysiological monitoring in spinal cord surgery
    Angel Collado-Corona, Miguel
    de Leo-Vargas, Roberto
    Sandoval-Sanchez, Victor
    Diaz-Hernandez, Alejandro
    Jose Gutierrez-Sougarret, Bernardo
    Shkurovich-Bialik, Paul
    CIRUGIA Y CIRUJANOS, 2009, 77 (05): : 361 - 366
  • [3] Assessment of intraoperative neurophysiological monitoring techniques in intramedullary spinal cord tumor removal surgery
    Nguyen, Minh Anh
    Ngo, Anh Phung
    Huynh, Quoc Bao
    Pham, Thanh Binh
    Nguyen, Viet Hoa
    INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2023, 32
  • [4] Intraoperative Neurophysiologic Monitoring and Mapping During Surgery on Intramedullary Spinal Cord Tumors in Children and Adolescents
    Seidel, Kathleen
    Deletis, Vedran
    Raabe, Andreas
    Lutz, Katharina
    Schucht, Philippe
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2024, 41 (02) : 116 - 122
  • [5] Diagnostic Utility of Intraoperative Neurophysiological Monitoring for Intramedullary Spinal Cord Tumors: Systematic Review and Meta-Analysis
    Azad, Tej D.
    Pendharkar, Arjun V.
    Nguyen, Viet
    Pan, James
    Connolly, Ian D.
    Veeravagu, Anand
    Popat, Rita
    Ratliff, John K.
    Grant, Gerald A.
    CLINICAL SPINE SURGERY, 2018, 31 (03): : 112 - 119
  • [6] Dorsal column mapping in resection of intramedullary spinal cord tumors: a prospective comparison of two methods and neurological follow-up
    Ueberschaer, Moritz
    Breitkopf, Katharina
    Siller, Sebastian
    Katzendobler, Sophie
    Weller, Jonathan
    Greve, Tobias
    Zausinger, Stefan
    Tonn, Joerg-Christian
    Szelenyi, Andrea
    ACTA NEUROCHIRURGICA, 2023, 165 (11) : 3493 - 3504
  • [7] Intramedullary spinal cord tumor surgery: can we do it without intraoperative neurophysiological monitoring?
    Hsu, Wesley
    Bettegowda, Chetan
    Jallo, George I.
    CHILDS NERVOUS SYSTEM, 2010, 26 (02) : 241 - 245
  • [8] Continuous mapping of the corticospinal tracts in intramedullary spinal cord tumor surgery using an electrified ultrasonic aspirator
    Barzilai, Ori
    Lidar, Zvi
    Constantini, Shlomi
    Salame, Khalil
    Bitan-Talmor, Yifat
    Korn, Akiva
    JOURNAL OF NEUROSURGERY-SPINE, 2017, 27 (02) : 161 - 168
  • [9] Combined motor and somatosensory evoked potential monitoring for intramedullary spinal cord tumor surgery: correlation of clinical and neurophysiological data in 17 consecutive procedures
    Hyun, Seung-Jae
    Rhim, Seung-Chul
    BRITISH JOURNAL OF NEUROSURGERY, 2009, 23 (04) : 393 - 400
  • [10] Multimodal Intraoperative Neurophysiological Monitoring in Spinal Cord Surgery
    Taskiran, Emine
    Brandmeier, Sema
    Ozek, Erdinc
    Saris, Ramazan
    Bolukbasi, Fatihhan
    Elmaci, Ilhan
    TURKISH NEUROSURGERY, 2017, 27 (03) : 436 - 440