SBRT treatment of abdominal and pelvic oligometastatic lymph nodes using ring-mounted Halcyon Linac

被引:14
作者
Pokhrel, Damodar [1 ]
Webster, Aaron [1 ]
Stephen, Joseph [1 ]
St Clair, William [1 ]
机构
[1] Univ Kentucky, Med Phys Grad Program, Dept Radiat Med, Lexington, KY 40506 USA
关键词
AcurosXB; Coplanar Geometry; FFF‐ beam; Halcyon Linac; oligometastatic lymph nodes SBRT; single‐ isocenter VMAT; BODY RADIATION-THERAPY; STEREOTACTIC RADIOTHERAPY; SINGLE-ISOCENTER; DOSE CALCULATION; FEASIBILITY; TARGETS;
D O I
10.1002/acm2.13268
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose/objectives This work seeks to evaluate the plan quality, treatment delivery efficiency, and accuracy of single-isocenter volumetric modulated arc therapy (VMAT) of abdominal/pelvic oligometastatic lymph nodes (LNs) stereotactic body radiation therapy (SBRT) on Halcyon Linac. Materials and Methods After completing the in-house multitarget end-to-end phantom testing and independent dose verification using MD Anderson's single-isocenter/multi-target (lung and spine target inserts) thorax phantom, eight patients with two to three abdominal/pelvic oligometastatic LNs underwent highly conformal single-isocenter VMAT-SBRT treatment using the Halcyon Linac 6MV flattening filter free (FFF) beam. Targets were identified using an Axumin PET/CT scan co-registered with planning CT images and a single-isocenter was placed between/among the targets. Doses between 25 and 36.25 Gy in 5 fractions were delivered. Patients were treated every other day. Plans were calculated in Eclipse with advanced AcurosXB algorithm for heterogeneity corrections. For comparison, Halcyon VMAT-SBRT plans were retrospectively generated for SBRT-dedicated TrueBeam with a 6MV-FFF beam using identical planning geometry and objectives. Target coverage, conformity index (CI), dose to 2 cm away from each target (D2cm) and dose to adjacent organs-at-risk (OAR) were evaluated. Additionally, various treatment delivery parameters including beam-on time were recorded. Results Phantom measurements showed acceptable spatial accuracy of conebeam CT-guided Halcyon SBRT treatments including compliance with MD Anderson's single-isocenter/multi-targets phantom credentialing results. For patients, the mean isocenter to tumor center distance was 3.4 +/- 1.2 cm (range, 1.5-4.8 cm). The mean combined PTV was 18.9 +/- 10.9 cc (range, 5.6-39.5 cc). There was no clinically significant difference in dose to LNs, CI, D2cm and maximal doses to OAR between single-isocenter Halcyon and Truebeam VMAT-SBRT plans, although, Halcyon plans provided preferably lower maximal dose to adjacent OAR. Additionally, total monitor units, beam-on time and overall treatment time was lower with Halcyon plans. Halcyon's portal dosimetry demonstrated a high pass rate of 98.1 +/- 1.6% for clinical gamma passing criteria of 2%/2 mm. Conclusion SBRT treatment of abdominal/pelvic oligometastatic LNs with single-isocenter VMAT on Halcyon was dosimetrically equivalent to TrueBeam. Faster treatment delivery to oligometastatic LNs via single-isocenter Halcyon VMAT can improve clinic workflow and patient compliance, potentially reducing intrafraction motion errors for well-suited patients. Clinical follow-up of these patients is ongoing.
引用
收藏
页码:162 / 171
页数:10
相关论文
共 49 条
[21]   Using the iterative kV CBCT reconstruction on the Varian Halcyon linear accelerator for radiation therapy planning for pelvis patients [J].
Jarema, Talia ;
Aland, Trent .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 68 :112-116
[22]   Is Stereotactic Body Radiotherapy (SBRT) in lymph node oligometastatic patients feasible and effective? [J].
Jereczek-Fossa, Barbara Alicja ;
Ronchi, Sara ;
Orecchia, Roberto .
REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2015, 20 (06) :472-483
[23]   ROBOTIC IMAGE-GUIDED STEREOTACTIC RADIOTHERAPY, FOR ISOLATED RECURRENT PRIMARY, LYMPH NODE OR METASTATIC PROSTATE CANCER [J].
Jereczek-Fossa, Barbara Alicja ;
Beltramo, Giancarlo ;
Fariselli, Laura ;
Fodor, Cristiana ;
Santoro, Luigi ;
Vavassori, Andrea ;
Zerini, Dario ;
Gherardi, Federica ;
Ascione, Carmen ;
Bossi-Zanetti, Isa ;
Mauro, Roberta ;
Bregantin, Achille ;
Bianchi, Livia Corinna ;
De Cobelli, Ottavio ;
Orecchia, Roberto .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (02) :889-897
[24]   Treatment plan adaptation for MRI-guided radiotherapy using solely MRI data: a CT-based simulation study [J].
Kerkhof, E. M. ;
Balter, J. M. ;
Vineberg, K. ;
Raaymakers, B. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16) :N433-N440
[25]   Early clinical experience with varian halcyon V2 linear accelerator: Dual-isocenter IMRT planning and delivery with portal dosimetry for gynecological cancer treatments [J].
Kim, Hayeon ;
Huq, M. Saiful ;
Lalonde, Ron ;
Houser, Christopher J. ;
Beriwal, Sushil ;
Heron, Dwight E. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (11) :111-120
[26]   Intracranial Stereotactic Radiation Therapy With a Jawless Ring Gantry Linear Accelerator Equipped With New Dual Layer Multileaf Collimator [J].
Knutson, Nels C. ;
Kennedy, William R. ;
Reynoso, Francisco J. ;
Peng, Jiayuan ;
Henke, Lauren E. ;
Laugeman, Eric ;
Watts, Michael ;
Hillard, Jessica ;
Heermann, Ana ;
Hugo, Geoffrey D. ;
Mutic, Sasa ;
Cai, Bin .
ADVANCES IN RADIATION ONCOLOGY, 2020, 5 (03) :482-489
[27]   Dosimetric accuracy and clinical quality of Acuros XB and AAA dose calculation algorithm for stereotactic and conventional lung volumetric modulated arc therapy plans [J].
Kroon, Petra S. ;
Hol, Sandra ;
Essers, Marion .
RADIATION ONCOLOGY, 2013, 8
[28]   Comprehensive validation of halcyon 2.0 plans and the implementation of patient specific QA with multiple detector platforms [J].
Laugeman, Eric ;
Heermann, Ana ;
Hilliard, Jessica ;
Watts, Michael ;
Roberson, Marshia ;
Morris, Robert ;
Goddu, Sreekrishna ;
Sethi, Abhishek ;
Zoberi, Imran ;
Kim, Hyun ;
Mutic, Sasa ;
Hugo, Geoffrey ;
Cai, Bin .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (07) :39-48
[29]   Frameless stereotactic body radiation therapy for multiple lung metastases [J].
Li, Qilin ;
Mu, Jinming ;
Gu, Wendong ;
Chen, Yuan ;
Ning, Zhonghua ;
Jin, Jianxue ;
Pei, Honglei .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (04) :105-116
[30]   Dosimetric Performance and Planning/Delivery Efficiency of a Dual-Layer Stacked and Staggered MLC on Treating Multiple Small Targets: A Planning Study Based on Single-Isocenter Multi-Target Stereotactic Radiosurgery (SRS) to Brain Metastases [J].
Li, Taoran ;
Irmen, Peyton ;
Liu, Haisong ;
Shi, Wenyin ;
Alonso-Basanta, Michelle ;
Zou, Wei ;
Teo, Boon-Keng Kevin ;
Metz, James M. ;
Dong, Lei .
FRONTIERS IN ONCOLOGY, 2019, 9