SBRT treatment of abdominal and pelvic oligometastatic lymph nodes using ring-mounted Halcyon Linac

被引:14
作者
Pokhrel, Damodar [1 ]
Webster, Aaron [1 ]
Stephen, Joseph [1 ]
St Clair, William [1 ]
机构
[1] Univ Kentucky, Med Phys Grad Program, Dept Radiat Med, Lexington, KY 40506 USA
关键词
AcurosXB; Coplanar Geometry; FFF‐ beam; Halcyon Linac; oligometastatic lymph nodes SBRT; single‐ isocenter VMAT; BODY RADIATION-THERAPY; STEREOTACTIC RADIOTHERAPY; SINGLE-ISOCENTER; DOSE CALCULATION; FEASIBILITY; TARGETS;
D O I
10.1002/acm2.13268
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose/objectives This work seeks to evaluate the plan quality, treatment delivery efficiency, and accuracy of single-isocenter volumetric modulated arc therapy (VMAT) of abdominal/pelvic oligometastatic lymph nodes (LNs) stereotactic body radiation therapy (SBRT) on Halcyon Linac. Materials and Methods After completing the in-house multitarget end-to-end phantom testing and independent dose verification using MD Anderson's single-isocenter/multi-target (lung and spine target inserts) thorax phantom, eight patients with two to three abdominal/pelvic oligometastatic LNs underwent highly conformal single-isocenter VMAT-SBRT treatment using the Halcyon Linac 6MV flattening filter free (FFF) beam. Targets were identified using an Axumin PET/CT scan co-registered with planning CT images and a single-isocenter was placed between/among the targets. Doses between 25 and 36.25 Gy in 5 fractions were delivered. Patients were treated every other day. Plans were calculated in Eclipse with advanced AcurosXB algorithm for heterogeneity corrections. For comparison, Halcyon VMAT-SBRT plans were retrospectively generated for SBRT-dedicated TrueBeam with a 6MV-FFF beam using identical planning geometry and objectives. Target coverage, conformity index (CI), dose to 2 cm away from each target (D2cm) and dose to adjacent organs-at-risk (OAR) were evaluated. Additionally, various treatment delivery parameters including beam-on time were recorded. Results Phantom measurements showed acceptable spatial accuracy of conebeam CT-guided Halcyon SBRT treatments including compliance with MD Anderson's single-isocenter/multi-targets phantom credentialing results. For patients, the mean isocenter to tumor center distance was 3.4 +/- 1.2 cm (range, 1.5-4.8 cm). The mean combined PTV was 18.9 +/- 10.9 cc (range, 5.6-39.5 cc). There was no clinically significant difference in dose to LNs, CI, D2cm and maximal doses to OAR between single-isocenter Halcyon and Truebeam VMAT-SBRT plans, although, Halcyon plans provided preferably lower maximal dose to adjacent OAR. Additionally, total monitor units, beam-on time and overall treatment time was lower with Halcyon plans. Halcyon's portal dosimetry demonstrated a high pass rate of 98.1 +/- 1.6% for clinical gamma passing criteria of 2%/2 mm. Conclusion SBRT treatment of abdominal/pelvic oligometastatic LNs with single-isocenter VMAT on Halcyon was dosimetrically equivalent to TrueBeam. Faster treatment delivery to oligometastatic LNs via single-isocenter Halcyon VMAT can improve clinic workflow and patient compliance, potentially reducing intrafraction motion errors for well-suited patients. Clinical follow-up of these patients is ongoing.
引用
收藏
页码:162 / 171
页数:10
相关论文
共 49 条
[1]   Rationale of technical requirements for NRG-BR001: The first NCI-sponsored trial of SBRT for the treatment of multiple metastases [J].
Al-Hallaq, Hania A. ;
Chmura, Steven ;
Salama, Joseph K. ;
Winter, Kathryn A. ;
Robinson, Clifford G. ;
Pisansky, Thomas M. ;
Borges, Virginia ;
Lowenstein, Jessica R. ;
McNulty, Susan ;
Galvin, James M. ;
Followill, David S. ;
Timmerman, Robert D. ;
White, Julia R. ;
Xiao, Ying ;
Matuszak, Martha M. .
PRACTICAL RADIATION ONCOLOGY, 2016, 6 (06) :E291-E298
[2]   Volumetric modulated arc therapy with flattening filter free beams for isolated abdominal/pelvic lymph nodes: report of dosimetric and early clinical results in oligometastatic patients [J].
Alongi, Filippo ;
Fogliata, Antonella ;
Clerici, Elena ;
Navarria, Pierina ;
Tozzi, Angelo ;
Comito, Tiziana ;
Ascolese, Anna Maria ;
Clivio, Alessandro ;
Lobefalo, Francesca ;
Reggiori, Giacomo ;
Cozzi, Luca ;
Mancosu, Pietro ;
Tomatis, Stefano ;
Scorsetti, Marta .
RADIATION ONCOLOGY, 2012, 7
[3]   Review and Uses of Stereotactic Body Radiation Therapy for Oligometastases [J].
Alongi, Filippo ;
Arcangeli, Stefano ;
Filippi, Andrea Riccardo ;
Ricardi, Umberto ;
Scorsetti, Marta .
ONCOLOGIST, 2012, 17 (08) :1100-1107
[4]  
[Anonymous], 2019, ECLIPSE ALGORITHMS R
[5]  
[Anonymous], 2019, VARIAN HALCYON LINAC
[6]   Stereotactic body radiation therapy: The report of AAPM Task Group 101 [J].
Benedict, Stanley H. ;
Yenice, Kamil M. ;
Followill, David ;
Galvin, James M. ;
Hinson, William ;
Kavanagh, Brian ;
Keall, Paul ;
Lovelock, Michael ;
Meeks, Sanford ;
Papiez, Lech ;
Purdie, Thomas ;
Sadagopan, Ramaswamy ;
Schell, Michael C. ;
Salter, Bill ;
Schlesinger, David J. ;
Shiu, Almon S. ;
Solberg, Timothy ;
Song, Danny Y. ;
Stieber, Volker ;
Timmerman, Robert ;
Tome, Wolfgang A. ;
Verellen, Dirk ;
Wang, Lu ;
Yin, Fang-Fang .
MEDICAL PHYSICS, 2010, 37 (08) :4078-4101
[7]   CLINICAL OUTCOME OF HYPOFRACTIONATED STEREOTACTIC RADIOTHERAPY FOR ABDOMINAL LYMPH NODE METASTASES [J].
Bignardi, Mario ;
Navarria, Piera ;
Mancosu, Pietro ;
Cozzi, Luca ;
Fogliata, Antonella ;
Tozzi, Angelo ;
Castiglioni, Simona ;
Carnaghi, Carlo ;
Tronconi, Maria Chiara ;
Santoro, Armando ;
Scorsetti, Marta .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (03) :831-838
[8]   Inter-fraction movements of the prostate and pelvic lymph nodes during IGRT [J].
Bjoreland, Ulrika ;
Jonsson, Joakim ;
Alm, Magnus ;
Beckman, Lars ;
Nyholm, Tufve ;
Thellenberg-Karlsson, Camilla .
JOURNAL OF RADIATION ONCOLOGY, 2018, 7 (04) :357-366
[9]  
Bonomo P, 2013, TUMORI, V99, P611, DOI 10.1700/1377.15311
[10]   Characterization of a prototype rapid kilovoltage x-ray image guidance system designed for a ring shape radiation therapy unit [J].
Cai, Bin ;
Laugeman, Eric ;
Mazur, Thomas R. ;
Park, Justin C. ;
Henke, Lauren E. ;
Kim, Hyun ;
Hugo, Geoffrey D. ;
Mutic, Sasa ;
Li, Hua .
MEDICAL PHYSICS, 2019, 46 (03) :1355-1370