In vitro studies show synergistic effects of a procoagulant bispecific antibody and bypassing agents

被引:56
作者
Hartmann, R. [1 ]
Feenstra, T. [1 ]
Valentino, L. [2 ]
Dockal, M. [1 ]
Scheiflinger, F. [1 ]
机构
[1] Shire, Donau City Str 7, A-1220 Vienna, Austria
[2] Shire, Bannockburn, IL USA
关键词
activated partial thromboplastin time; emicizumab; FEIBA; hemophilia A; thrombotic microangiopathies; FLOW-CHAMBER SYSTEM; VON-WILLEBRAND DISEASE; FACTOR-VIII; HEMOPHILIA-A; INTRAABDOMINAL MALIGNANCIES; HYPERCOAGULABLE STATE; THROMBIN GENERATION; INHIBITORS; BLOOD; COAGULATION;
D O I
10.1111/jth.14203
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Investigational non-factor products such as emicizumab offer a treatment option for patients with hemophilia and inhibitors. However, their mechanism of action raises questions regarding safety when they are combined with treatments for breakthrough bleeding. Objectives: To evaluate in vitro thrombin generation (TG) and clot formation for combinations of activated prothrombin complex concentrate (aPCC), recombinant activated factor VII (rFVIIa), and a sequence-identical analog of emicizumab (SIA). Methods: Therapeutic concentrations of SIA (20-600 nM) alone or with aPCC (0.05-1 U mL(-1)), isolated aPCC components or rFVIIa (0.885.25 mu g mL(-1)) were tested for TG and compared with reference ranges for healthy donor plasma. Coagulation of FVIII-inhibited blood was determined with a widely established method, i.e. rotational thromboelastometry (ROTEM), and confirmed with the Total Thrombusformation Analysis System. Results and conclusions: SIA (600 nM) or aPCC (0.5 U mL(-1)) alone resulted in peak thrombin levels of 21.4 nM and 38.6 nM, respectively, both of which are lower than normal (83.7 +/- 29.8 nM). SIA plus aPCC (0.5 U mL(-1)) increased the peak thrombin level 17-fold over SIA alone, exceeding the reference plasma value by 4.2-fold. This hypercoagulable effect occurred with 600 nM SIA combined with as little as 0.25 U mL(-1) aPCC, confirmed by ROTEM. FIX was the main driver for enhanced TG. SIA plus rFVIIa (1.75 mu g mL(-1)) induced a 1.8-fold increase in the peak thrombin level in platelet-rich plasma, but it did not reach the normal range. These in vitro experiments demonstrate excessive TG after administration of a combination of aPCC and SIA at clinically relevant doses. Careful judgement may be required when breakthrough bleeding is treated in patients receiving emicizumab.
引用
收藏
页码:1580 / 1591
页数:12
相关论文
共 37 条
[31]   Predictability of serious adverse reaction alerts for monoclonal antibodies [J].
Stanulovic, V. ;
Zelko, R. ;
Kerpel-Fronius, S. .
INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2011, 49 (03) :185-190
[32]  
Sugihara Hidekazu, 2016, J Clin Med Res, V8, P899
[33]   Persistence of Hypercoagulable State after Resection of Intra-Abdominal Malignancies [J].
Thorson, Chad M. ;
Van Haren, Robert M. ;
Ryan, Mark L. ;
Curia, Emiliano ;
Sleeman, Danny ;
Levi, Joe U. ;
Livingstone, Alan S. ;
Proctor, Kenneth G. .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2013, 216 (04) :580-589
[34]   Global coagulation in myeloproliferative neoplasms [J].
Tripodi, Armando ;
Chantarangkul, Veena ;
Gianniello, Francesca ;
Clerici, Marigrazia ;
Lemma, Laura ;
Padovan, Lidia ;
Gatti, Loredana ;
Mannucci, Pier Mannuccio ;
Peyvandi, Flora .
ANNALS OF HEMATOLOGY, 2013, 92 (12) :1633-1639
[35]   Pro- and anticoagulant factors facilitate thrombin generation and balance the haemostatic response to FEIBA® in prophylactic therapy [J].
Varadi, K. ;
Tangada, S. ;
Loeschberger, M. ;
Montsch, P. ;
Schrenk, G. ;
Ewenstein, B. ;
Turecek, P. L. .
HAEMOPHILIA, 2016, 22 (04) :615-624
[36]  
WHO. International nonproprietary names for pharmaceutical substances (INN), 2015, WHO DRUG INF, V29, P195
[37]   Studies of a microchip flow-chamber system to characterize whole blood thrombogenicity in healthy individuals [J].
Yamaguchi, Yusuke ;
Moriki, Takanori ;
Igari, Atsuko ;
Matsubara, Yumiko ;
Ohnishi, Tomoko ;
Hosokawa, Kazuya ;
Murata, Mitsuru .
THROMBOSIS RESEARCH, 2013, 132 (02) :263-270