A novel immobilization multienzyme glucose fluorescence capillary biosensor

被引:24
|
作者
Li, Yong-Sheng [1 ]
Du, Yun-Dong [1 ]
Chen, Ting-Mei [1 ]
Gao, Xiu-Feng [2 ]
机构
[1] Sichuan Univ, Sch Chem Engn, Chengdu 610065, Peoples R China
[2] Sichuan Univ, W China Sch Preclin & Forens Med, Chengdu 610041, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2010年 / 25卷 / 06期
关键词
Fluorescence capillary analysis; Biosensor; Immobilization enzyme; Glucose oxidase; Horseradish peroxidase; L-Tyrosine; LABORATORY EXPERIMENT; OXIDASE; ACID;
D O I
10.1016/j.bios.2009.10.035
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Based on the immobilization enzyme technology and the fluorescence capillary analysis method, the authors have developed a highly sensitive fluorescence reaction system and a novel immobilization multienzyme glucose fluorescence capillary biosensor for determining glucose contents. Reaction principle of the system is that under the catalysis of glucose oxidase (GOD) and horseradish peroxidase (HRP) immobilized on inner surface of a medical capillary, beta-D-glucose reacts with dissolved oxygen to form gluconic acid-delta-lactone and hydrogen peroxide, and then the latter reacts with L-tyrosine to produce a tyrosine dimer, which has maximal excitation and emission wavelengths at 320 nm and 410 nm, respectively. Fluorescence of the dimer is proportional to the concentration of the beta-D-glucose. Optimization conditions suitable for the reaction system and the biosensor were as follows. Concentration of the L-tyrosine used as fluorescence reagent was 0.15 mol L-1, the active concentrations of the GOD and the HRP for the immobilization were 15 kU L-1 and 8 kU L-1, respectively. Consumptions of the sample and reagents in one determination were 5.0 mu L and 15 mu L, respectively. Quantitative range of the biosensor for the glucose was in the range 1-10 mu mol L-1, its relative standard deviation was less than 4.9%, and its detection limit was 0.62 mu mol L-1. The biosensor's recovery was in the range 96-105%. Results of some serum determined with the biosensor and with a commercial glucose-kit were well coincident to each other. Accordingly, the biosensor can be applied to the determination of serum glucose contents in the diagnosis of diabetes. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1382 / 1388
页数:7
相关论文
共 50 条
  • [1] A Novel Immobilization Enzyme Lactate Fluorescence Capillary Biosensor
    Li Yong-Sheng
    Ju Xiang
    Gao Xiu-Feng
    Yang Wei
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (05) : 637 - 642
  • [2] A novel immobilization fluorescence capillary analysis method and its applications
    Li, Yong-Sheng
    Li, Qiao-Jing
    Gao, Xiu-Feng
    ANALYST, 2020, 145 (06) : 1980 - 1996
  • [3] A novel fiber optic glucose biosensor based on fluorescence quenching
    Jiang, DS
    Liu, E
    Huang, J
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS, 2002, 4920 : 205 - 212
  • [4] Determination of Glucose with Biosensor by Immobilization of Glucose Oxidase with Chitosan
    Zhang Yan
    Nan Cai-Feng
    Feng Li
    Zhang Li-Qin
    Dong Chuan
    Shuang Shao-Min
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (07) : 1049 - 1052
  • [5] Integrated capillary fluorescence DNA biosensor
    Breimer, MA
    Gelfand, Y
    Sadik, OA
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (09): : 1135 - 1147
  • [6] An immobilization multienzyme microfluidic chip for acetylcholinesterase inhibition assay by fluorescence method
    Tang, Yulan
    Liu, Sufang
    Pi, Rongbiao
    Cheng, Zhiyi
    RSC ADVANCES, 2016, 6 (25) : 20867 - 20875
  • [7] Analytical Parameters of a Novel Glucose Biosensor Based on Grafted PFM as a Covalent Immobilization Technique
    Artigues, Margalida
    Gilabert-Porres, Joan
    Texido, Robert
    Borros, Salvador
    Abella, Jordi
    Colominas, Sergi
    SENSORS, 2021, 21 (12)
  • [8] A novel glucose biosensor based on the immobilization of glucose oxidase onto gold nanoparticles-modified Pb nanowires
    Wang, Huicai
    Wang, Xinsheng
    Zhang, Xiaoqing
    Qin, Xia
    Zhao, Zixia
    Miao, Zhiying
    Huang, Nan
    Chen, Qiang
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (01): : 142 - 146
  • [9] An amperometric glucose biosensor based on the immobilization of glucose oxidase on the ZnO nanotubes
    Kong, Tao
    Chen, Yang
    Ye, Yiping
    Zhang, Kun
    Wang, Zhenxing
    Wang, Xiaoping
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (01): : 344 - 350
  • [10] A glucose biosensor based on immobilization of glucose oxidase in chitosan network matrix
    Yao, H
    Li, N
    Xu, JZ
    Zhu, JJ
    CHINESE JOURNAL OF CHEMISTRY, 2005, 23 (03) : 275 - 279