A clinical analysis of 4-and 6-year follow-up results after cervical disc replacement surgery using the Bryan Cervical Disc Prosthesis Clinical article

被引:76
作者
Goffin, Jan [1 ]
van Loon, Johan [1 ]
Van Calenbergh, Frank [1 ]
Lipscomb, Bailey [2 ]
机构
[1] Katholieke Univ Leuven, Dept Neurosurg, Louvain, Belgium
[2] Medtron Spinal & Biol, Memphis, TN USA
关键词
cervical disc degeneration; cervical disc arthroplasty; Bryan Cervical Disc Prosthesis; cervical spine; ARTIFICIAL DISC; SINGLE-LEVEL; DISEASE; RELIABILITY; FUSION;
D O I
10.3171/2009.9.SPINE09129
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. In this study, long-term results are presented from clinical studies of the Bryan Cervical Disc Prosthesis at University Hospital Gasthuisberg in Leuven, Belgium. A total of 98 patients (89 with 1-level and 9 with 2-level implantations) agreed to participate in follow-up studies for up to 10 years postoperatively. This article focuses on the 4- and 6-year results. Patients in one of the clinical studies had either radiculopathy or myelopathy associated with spondylosis and/or disc herniations that did not respond to conservative treatment. Patients from the other clinical study received commercially available Bryan devices and the stud), protocol did not have specific inclusion/exclusion criteria. More than 90% of the patients were considered to have radiculopathy. Methods. Clinical measurements discussed in the article include the 36-Item Short Form Health Survey. Neck Disability Index, numerical ratings of neck and arm pain. neurological outcomes, and Odom classification. Angular motion findings from lateral flex ion-extension radiographs are also presented. The occurence of adverse events and second surgeries are examined as all indicator of device safety. Results. The clinical outcomes at 4 and 6 years postoperatively appear consistent With the Previously reported results at 1 and 2 years postoperatively. The mean angular motion results at 4 and 6 years postoperatively for 1-level patients were 7.3 and 7.7 degrees. respectively. Two-level patients had slightly less motion at 4 and 6 years postoperatively with mean caudad values of 5.7 and 6.0 degrees, respectively, and cephalad values of 4.2 and 6.2 degrees. respectively. Efforts were made to capture adverse events, regardless of their nature and relatedness to the study surgery. This effort resulted in a relatively high number of recorded events. However, only 6 patients experienced events that were judged by the investigator to be related, either possibly or definitely, to the Bryan device. These events included device migration. device removal, and hoarseness and vocal cord paralysis, as well as 3 cases involving pain and neurological symptoms. Eight patients underwent further neck surgery to treat symptoms. Conclusions. The favorable clinical and angular motion outcomes that were Previously noted at 1- and 2-years' follow-up after cervical disc replacement with the Bryan Cervical Disc Prosthesis appear to persist after 4 and 6 years of follow-up. (DOI: 10.3171/2009.9.SPINE09129)
引用
收藏
页码:261 / 269
页数:9
相关论文
共 19 条
  • [1] Bryan cervical disc prosthesis: 12-month clinical outcome
    Amit, A.
    Dorward, N.
    [J]. BRITISH JOURNAL OF NEUROSURGERY, 2007, 21 (05) : 478 - 484
  • [2] Comparison of adverse events between the Bryan artificial cervical disc and anterior cervical arthrodesis
    Anderson, Paul A.
    Sasso, Rick C.
    Riew, K. Daniel
    [J]. SPINE, 2008, 33 (12) : 1305 - 1312
  • [3] Prospective randomized controlled study of the Bryan Cervical Disc: early clinical results from a single investigational site - Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2005
    Coric, D
    Finger, F
    Boltes, P
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2006, 4 (01) : 31 - 35
  • [4] Duggal Neil, 2004, Neurosurg Focus, V17, pE9
  • [5] Long-term follow-up after interbody fusion of the cervical spine
    Goffin, J
    Geusens, E
    Vantomme, N
    Quintens, E
    Waerzeggers, Y
    Depreitere, B
    Van Calenbergh, F
    van Loon, J
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2004, 17 (02): : 79 - 85
  • [6] Preliminary clinical experience with the Bryan Cervical Disc Prosthesis
    Goffin, J
    Casey, A
    Kehr, P
    Liebig, K
    Lind, B
    Logroscino, C
    Pointillart, V
    Van Calenbergh, F
    van Loon, J
    [J]. NEUROSURGERY, 2002, 51 (03) : 840 - 845
  • [7] Intermediate follow-up after treatment of degenerative disc disease with the Bryan Cervical Disc Prosthesis: Single-level and bi-level
    Goffin, J
    Van Calenbergh, F
    van Loon, J
    Casey, A
    Kehr, P
    Liebig, K
    Lind, B
    Logroscino, C
    Sgrambiglia, R
    Pointillart, V
    [J]. SPINE, 2003, 28 (24) : 2673 - 2678
  • [8] Intervertebral disc replacement for cervical degenerative disease -: clinical results and functional outcome at two years in patients implanted with the Bryan® cervical disc prosthesis
    Heidecke, V.
    Burkert, W.
    Brucke, M.
    Rainov, N. G.
    [J]. ACTA NEUROCHIRURGICA, 2008, 150 (05) : 453 - 459
  • [9] McDowell I., 1996, MEASURING HLTH GUIDE, P341
  • [10] THE MOS 36-ITEM SHORT-FORM HEALTH SURVEY (SF-36) .3. TESTS OF DATA QUALITY, SCALING ASSUMPTIONS, AND RELIABILITY ACROSS DIVERSE PATIENT GROUPS
    MCHORNEY, CA
    WARE, JE
    LU, JFR
    SHERBOURNE, CD