摘要
The fact, that some areas need district heating through heat pumps and at the same time recover residual heat from geothermal water, presents a new working condition: feed water temperature of heat network 80 degreesC, return water temperature 65 degreesC; discarded geothermal water temperature 40 degreesC and its emission standard temperature below 30 degreesC. But none of known pure refrigerants and mixtures can meet this requirement. The paper introduces a novel approach named temperature-matching method, which provides a direction in selecting high-performance working fluids for further research. It is shown from the results that the mean COPs of binary and ternary mixtures are 4.85 and 4.74 respectively, but that of pure refrigerants is 4.12 under the same ambient condition. This point indicates that temperature matching contributes to energy saving. The novel approach to high-performance working fluids can be conveniently introduced into other working conditions. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:179 / 195
页数:17
相关论文
共 12 条
[1]   The potential of district heating using geothermal energy. A case study, Greece [J].
Agioutantis, Z ;
Bekas, A .
GEOTHERMICS, 2000, 29 (01) :51-64
[2]  
ATLANTA G, ASHRAE HDB 1993 FUND
[3]   Performance and heat transfer characteristics of hydrocarbon refrigerants in a heat pump system [J].
Chang, YS ;
Kim, MS ;
Ro, ST .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2000, 23 (03) :232-242
[4]   CALCULATION METHODS FOR COMPARING THE PERFORMANCE OF PURE AND MIXED WORKING FLUIDS IN HEAT-PUMP APPLICATIONS [J].
HOGBERG, M ;
VAMLING, L ;
BERNTSSON, T .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1993, 16 (06) :403-413
[5]   A study on the performance of multi-stage heat pumps using mixtures [J].
Jung, DS ;
Kim, HJ ;
Kim, O .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1999, 22 (05) :402-413
[6]   Evaluation of low temperature geothermal energy through the use of heat pump [J].
Kara, YA ;
Yuksel, B .
ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (06) :773-781
[7]   World-wide direct uses of geothermal energy 2000 [J].
Lund, JW ;
Freeston, DH .
GEOTHERMICS, 2001, 30 (01) :29-68
[8]   METHODS FOR COMPARING THE PERFORMANCE OF PURE AND MIXED REFRIGERANTS IN THE VAPOR COMPRESSION CYCLE [J].
MCLINDEN, MO ;
RADERMACHER, R .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1987, 10 (06) :318-325
[9]  
*NIST, 1998, NIST REFPROP STAND R
[10]   Environmental protection of geothermal waters and travertines at Pamukkale, Turkey [J].
Simsek, S ;
Günay, G ;
Elhatip, H ;
Ekmekçi, M .
GEOTHERMICS, 2000, 29 (4-5) :557-572