Analysis of non-uniform charge/discharge and rate effects in porous carbon capacitors containing sub-optimal electrolyte concentrations

被引:142
作者
Pell, WG
Conway, BE
Marincic, N
机构
[1] Univ Ottawa, Fac Sci, Dept Chem, Ottawa, ON K1N 6N5, Canada
[2] Redox Engn Inc, Winchester, MA 01890 USA
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 2000年 / 491卷 / 1-2期
基金
加拿大自然科学与工程研究理事会;
关键词
electrochemical capacitors; porous electrodes;
D O I
10.1016/S0022-0728(00)00207-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The effects of internal electrolyte resistance on the acceptance and delivery of charge by a series of 3 V, non-aqueous, double-layer capacitors have been investigated by cyclic voltammetry and de charging/discharging procedures conducted at different rates. The data obtained enable Ragone plots to be constructed for the performance of the capacitor modules. A series of four capacitor modules have been constructed using 2000 m(2) g(-1) carbon and containing tetraethylammonium tetrafluoroborate in dry propylene carbonate as electrolyte at four concentrations: 1.0, 0.4, 0.2 and 0.08 M. The lower concentrations are chosen to introduce electrolyte starvation deliberately and thus to be able to investigate the effects of such conditions on the discharge/recharge behaviour of the capacitor modules. In dilute solutions, electrolyte starvation can become enhanced on charge by redistribution of cations and anions of the electrolyte due to adsorption of the ions at respective negative and positive surfaces of the capacitor electrode matrices, from the electrolyte bulk. The magnitude of such effects depends on the adsorption charge capacity in relation to the total electrolyte ion concentrations available in the device and to the potential attained at the termination of charging. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:9 / 21
页数:13
相关论文
共 13 条