Evaluation of superficially and fully porous particles for HILIC separation of lanthanide-polyaminocarboxylic species and simultaneous coupling to ESIMS and ICPMS

被引:9
作者
Blanchard, E. [1 ,2 ]
Nonell, A. [1 ]
Chartier, F. [3 ]
Rincel, A. [1 ]
Bresson, C. [1 ]
机构
[1] Univ Paris Saclay, CEA, Lab Dev Analyt Nucl Isotop & Elementaire LANIE, Den Serv Etud Analyt & React Surfaces SEARS, F-91191 Gif Sur Yvette, France
[2] Sorbonne Univ, F-75005 Paris, France
[3] Univ Paris Saclay, CEA, Den Dept Phys Chim DPC, F-91191 Gif Sur Yvette, France
来源
RSC ADVANCES | 2018年 / 8卷 / 44期
关键词
HYDROPHILIC INTERACTION CHROMATOGRAPHY; PERFORMANCE LIQUID-CHROMATOGRAPHY; MRI CONTRAST AGENTS; SUB-2; MU-M; ORGANIC/HYDRO-ORGANIC MATRICES; OPTICAL-EMISSION SPECTROMETRY; PLASMA-MASS SPECTROMETRY; RARE-EARTH-ELEMENTS; CORE-SHELL; SPECIATION ANALYSIS;
D O I
10.1039/c8ra02961j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this work, amide-bonded columns packed with fully porous particles (FPP) and superficially porous particles (SPP) were evaluated to separate lanthanide-polyaminocarboxylic species by hydrophilic interaction liquid chromatography (HILIC), using two model samples of interest in nuclear and other industrial applications. We assessed the gains achieved by reducing the dimensions of the columns along with the size of the FPPs to sub-2 m and by using sub-3 m SPP-packed columns. The FPP-packed Acquity column (100 x 2.1 mm; 1.7 m) performed better than the SPP-packed Accucore column (150 x 2.1 mm; 2.6 m), with a separation that was two times more efficient and three times shorter, while generating around 30% less in effluent volumes. This column was also coupled simultaneously to electrospray ionisation mass spectrometry (ESIMS) and inductively coupled plasma mass spectrometry (ICPMS). The instrumental set-up was performed in a conventional laboratory, by taking into account the geometrical constraints existing in the laboratory dedicated to radioelement analysis. Furthermore, separation of the series of lanthanide (Ln) species was demonstrated for the first time thanks to the separation mode of hydrophilic interaction liquid chromatography.
引用
收藏
页码:24760 / 24772
页数:13
相关论文
共 44 条
  • [1] Evaluation of superficially porous and fully porous columns for analysis of drugs in plasma samples by UHPLC-MS/MS
    Acquaro Junior, Vinicius Ricardo
    Lancas, Fernando Mauro
    Costa Queiroz, Maria Eugenia
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1048 : 1 - 9
  • [2] Simple separation and characterization of lanthanide-polyaminocarboxylic acid complexes by HILIC ESI-MS
    Beuvier, L.
    Bresson, C.
    Nonell, A.
    Vio, L.
    Henry, N.
    Pichon, V.
    Chartier, F.
    [J]. RSC ADVANCES, 2015, 5 (113) : 92858 - 92868
  • [3] Tracing gadolinium-based contrast agents from surface water to drinking water by means of speciation analysis
    Birka, Marvin
    Wehe, Christoph A.
    Hachmoeller, Oliver
    Sperling, Michael
    Karst, Uwe
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2016, 1440 : 105 - 111
  • [4] Sensitive quantification of gadolinium-based magnetic resonance imaging contrast agents in surface waters using hydrophilic interaction liquid chromatography and inductively coupled plasma sector field mass spectrometry
    Birka, Marvin
    Wehe, Christoph A.
    Telgmann, Lena
    Sperling, Michael
    Karst, Uwe
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2013, 1308 : 125 - 131
  • [5] Sub-2 μm fully porous and partially porous (core-shell) stationary phases for reversed phase liquid chromatography
    Borges, Endler M.
    Rostagno, Mauricio A.
    Meireles, M. Angela A.
    [J]. RSC ADVANCES, 2014, 4 (44): : 22875 - 22887
  • [6] Evaluation of various HILIC materials for the fast separation of polar compounds
    Chauve, Benedicte
    Guillarme, Davy
    Cleon, Philippe
    Veuthey, Jean-Luc
    [J]. JOURNAL OF SEPARATION SCIENCE, 2010, 33 (6-7) : 752 - 764
  • [7] Rapid separation of lanthanides and actinides on small particle based reverse phase supports
    Datta, A.
    Sivaraman, N.
    Srinivasan, T. G.
    Rao, P. R. Vasudeva
    [J]. RADIOCHIMICA ACTA, 2010, 98 (05) : 277 - 285
  • [8] Are sub-2 μm particles best for separating small molecules? An alternative
    DeStefano, Joseph J.
    Boyes, Barry E.
    Schuster, Stephanie A.
    Miles, William L.
    Kirkland, Joseph J.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2014, 1368 : 163 - 172
  • [9] Comparison of superficially porous and fully porous silica supports used for a cyclofructan 6 hydrophilic interaction liquid chromatographic stationary phase
    Dolzan, Maressa D.
    Spudeit, Daniel A.
    Breitbach, Zachary S.
    Barber, William E.
    Micke, Gustavo A.
    Armstrong, Daniel W.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2014, 1365 : 124 - 130
  • [10] INFLUENCE OF THE PEAK HEIGHT DISTRIBUTION ON SEPARATION PERFORMANCES - DISCRIMINATION FACTOR AND EFFECTIVE PEAK-CAPACITY
    ELFALLAH, MZ
    MARTIN, M
    [J]. CHROMATOGRAPHIA, 1987, 24 : 115 - 122