Simple SPE-HPLC determination of some common drugs and herbicides of environmental concern by pulsed amperometry

被引:24
作者
Rivoira, L. [1 ]
De Carlo, R. M. [1 ]
Cavalli, S. [2 ]
Bruzzoniti, M. C. [1 ]
机构
[1] Univ Turin, Dept Chem, I-10125 Turin, Italy
[2] Consiglio Nazl Ric IRSA CNR, Ist Ric Acque, I-20861 Brugherio, MB, Italy
关键词
Amperometric detection; Glassy carbon electrode; RP-HPLC; Emerging contaminants; Water; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; PERSONAL CARE PRODUCTS; CARBON ELECTRODE; WATER; PHARMACEUTICALS; RESIDUES; BENTAZON; SURFACE; GROUNDWATER;
D O I
10.1016/j.talanta.2014.07.070
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work the electrochemical behavior of substances of environmental concern [bentazone, atrazine, carbamazepine, phenytoin and its metabolite 5-(4-hydroxyphenyl)-5-phenylhydantoin, HPPH] on a glassy carbon working electrode (Ag/AgCl reference electrode) was studied with the aim to develop a HPLC method coupled with amperometric detection. Constant potential (DC), pulsed amperometric detection modes were studied. For the pulsed mode, several waveforms were set and investigated. Detection conditions were optimized as a function of eluent pH. In order to reduce the limits of detection and to analyze natural water samples, a SPE protocol was optimized to be coupled to the developed procedure. For this aim, five sorbents of different physicochemical characteristics were tested optimizing a recovery procedure for each of the cartridge evaluated. At the optimized SPE conditions, recoveries were included in the range (R=90.2-100.5% for all the analytes, with excellent reproducibility (< %, n=3). The method detection limits obtained by pulsed amperometry after the SPE protocol (preconcentration factor 100) were 113 ng L-1 (0.47 nmol L-1), 67 ng L-1 (0.25 nmol L-1), 234 ng L-1 (1.1 nmol L-1), for bentazone, HPPH and carbamazepine, respectively. Robustness of the method was assessed for each analyte at a concentration level corresponding to about three times the limit of detection, through the evaluation of intra-day (n=13) and inter-day tests (4 days, n=52). Finally the method was successfully applied for the analysis of a river sample (Po River, Turin, Italy). (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:205 / 212
页数:8
相关论文
共 39 条
[31]  
Sarangapani S., 1984, P WORKSH EL CARB AUG
[32]   First HPLC-UV method for rapid and simultaneous quantification of phenobarbital, primidone, phenytoin, carbamazepine, carbamazepine-10,11-epoxide, 10,11-trans-dihydroxy-10,11-dihydrocarbamazepine, lamotrigine, oxcarbazepine and licarbazepine in human plasma [J].
Serralheiro, Ana ;
Alves, Gilberto ;
Fortuna, Ana ;
Rocha, Marilia ;
Falcao, Amilcar .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 925 :1-9
[33]  
Shi D.-D., 2012, ZHONGGUO NONGYE KEJI, V14, P145
[34]   ATRAZINE METABOLISM SELECTIVITY AND MODE OF ACTION [J].
SHIMABUKURO, RH ;
SWANSON, HR .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1969, 17 (02) :199-+
[35]   Pharmaceuticals and health care products in wastewater effluents: the example of carbamazepine [J].
Stamatelatou, K ;
Frouda, C ;
Fountoulakis, MS ;
Drillia, P ;
Kornaros, M ;
Lyberatos, G .
WATER RECYCLING IN THE MEDITERRANEAN REGION, 2003, 3 (04) :131-137
[36]   Electrochemical behavior of parent and photodegradation products of some selected pesticides [J].
Vaz, Carlos M. P. ;
Silva, Paulo R. V., Jr. ;
Prado, Isis ;
Castanho, Giuliane M. ;
Simoes, Fabio R. ;
Machado, Sergio A. S. .
QUIMICA NOVA, 2008, 31 (06) :1310-1314
[37]  
Yamanaka Hiroyuki, 2005, Drug Metab Pharmacokinet, V20, P135, DOI 10.2133/dmpk.20.135
[38]   Occurrence and biodegradability studies of selected pharmaceuticals and personal care products in sewage effluent [J].
Yu, Jim T. ;
Bouwer, Edward J. ;
Coelhan, Mehmet .
AGRICULTURAL WATER MANAGEMENT, 2006, 86 (1-2) :72-80
[39]   Development and validation of a high-performance liquid chromatographic procedure for the determination of herbicide residues in surface and agriculture waters [J].
Zanella, R ;
Primel, EG ;
Gonçalves, FF ;
Kurz, MHS ;
Mistura, CM .
JOURNAL OF SEPARATION SCIENCE, 2003, 26 (9-10) :935-938