Phase-drift suppression using harmonics in heterodyne detection and its application to optical coherence tomography

被引:13
作者
Sato, M
Seino, K
Onodera, K
Tanno, N
机构
[1] Yamagata Univ, Grad Sch Sci & Engn, Grad Program Human Sensing & Funct Sensor Engn, Yonezawa, Yamagata 9928510, Japan
[2] Yamagata Technopolis Fdn, Reg Joint Res Project Yamagata Prefecture, Yamagata 9902473, Japan
关键词
heterodyne beat signal; stabilization; harmonics; phase drift; optical coherence tomography;
D O I
10.1016/S0030-4018(00)00930-5
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrate phase-drift suppression (PDS) to enhance stabilization of the computed signal intensity (CSI) in heterodyne detection without optical and/or electronic feedback systems. CSI is defined as the square root of the sum of the squares of each harmonic intensity in the heterodyne beat signal. The PDS theoretically and experimentally demonstrates stabilizing conditions for modulation indexes and stability enhancements; for example, the CSI stability was enhanced 49 times through simulations and by 6.3 times through experiments for a modulation index of 2.62 rad. Optical coherence tomography images using a fiber Mach-Zehnder interferometer and a superluminescent diode verify the validity of PDS as an application. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:95 / 104
页数:10
相关论文
共 19 条
[1]   BLINDNESS LIMITATIONS IN OPTICAL COHERENCE DOMAIN REFLECTOMETRY [J].
CHINN, SR ;
SWANSON, EA .
ELECTRONICS LETTERS, 1993, 29 (23) :2025-2027
[2]   Recent advances in coherent detection imaging (CDI) in biomedicine: Laser tomography of human tissues in vivo and in vitro [J].
Devaraj, B ;
Usa, M ;
Chan, KP ;
Akatsuka, T ;
Inaba, H .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1996, 2 (04) :1008-1016
[3]  
Fercher A F, 1996, J Biomed Opt, V1, P157, DOI 10.1117/12.231361
[4]   ADJUSTABLE PHASE-CONTROL IN STABILIZED INTERFEROMETRY [J].
FRESCHI, AA ;
FREJLICH, J .
OPTICS LETTERS, 1995, 20 (06) :635-637
[5]   Multimode-laser reflectometer with a multichannel wavelength detector and its application [J].
Funaba, T ;
Tanno, N ;
Ito, H .
APPLIED OPTICS, 1997, 36 (34) :8919-8928
[6]   Laser frequency stabilization by means of optical self-heterodyne beat-frequency control [J].
Greiner, C ;
Boggs, B ;
Wang, T ;
Mossberg, TW .
OPTICS LETTERS, 1998, 23 (16) :1280-1282
[7]   Dispersion effects in partial coherence interferometry: Implications for intraocular ranging [J].
Hitzenberger, CK ;
Baumgartner, A ;
Drexler, W ;
Fercher, AF .
JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (01) :144-151
[8]   An optical coherence microscope for 3-dimensional imaging in developmental biology [J].
Hoeling, BM ;
Fernandez, AD ;
Haskell, RC ;
Huang, E ;
Myers, WR ;
Petersen, DC ;
Ungersma, SE ;
Wang, RY ;
Williams, ME ;
Fraser, SE .
OPTICS EXPRESS, 2000, 6 (07) :136-146
[9]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[10]   OPTICAL COHERENCE MICROSCOPY IN SCATTERING MEDIA [J].
IZATT, JA ;
HEE, MR ;
OWEN, GM ;
SWANSON, EA ;
FUJIMOTO, JG .
OPTICS LETTERS, 1994, 19 (08) :590-592