Quantification of coronary artery stenoses. Comparison of 64-slice and dual source CT angiography with cardiac catheterization

被引:10
|
作者
Busch, S. [1 ]
Nikolaou, K. [1 ]
Johnson, T. [1 ]
Rist, C. [1 ]
Knez, A. [1 ]
Reiser, M. [1 ]
Becker, C. [1 ]
机构
[1] Univ Munich, Klinikum Grosshadern, Inst Klin Radiol, D-81377 Munich, Germany
来源
RADIOLOGE | 2007年 / 47卷 / 04期
关键词
dual source CT; cardiac CT; cardiac catheterization; stenoses; CT-QCA;
D O I
10.1007/s00117-007-1476-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background. Until now stenoses of the coronary arteries have been evaluated visually with CT angiography. Therefore, the results were highly dependent on subjective factors inherent in the examiner. New software tools for semiquantitative analysis (CT-QCA, quantitative coronary assessment) might be adequate to improve the diagnostic accuracy und reproducibility. Material and methods. CTAs of 20 patients were analyzed. Ten patients each were evaluated using 64-slice CT (64SCT) and dual source CT (DSCT) (Somatom Sensation 64 and Somatom Definition, Siemens Medical Solutions, Forchheim), respectively. Two radiologists independently evaluated the data visually and with the help of a software tool (Syngo Circulation, Siemens Medical Solutions, Forchheim). The results of the quantitative assessment of the invasive heart catheterization served as the reference standard. Sensitivity and specificity as well as the correlation coefficient, the systematic error, and the interobserver agreement (kappa) were determined. Results. In each of both patient groups 12 stenoses were detected. For the detection of stenoses > 75%, sensitivity and specificity for the visual evaluation using the 64SCT were 100% and 90%, and with the CT-QCA both were 100%. For the DSCT sensitivity and specificity were 100% for both the visual and semiautomated evaluation. The Bland-Altman plot of the results of the 64SCT showed an overestimation of 3.3% (+/- 62.7%/56.2%) compared to the heart catheterization. The results of the DSCT exhibited an overestimation of 6.2% (+/- 33.1%/19.8%). The interobserver agreement of the CT-QCA and the visual evaluation showed a kappa value of 0.75 and for DSCT of 1.0. Conclusion. The results showed a good correlation of grading stenosis between the software-assisted evaluation and the results of the coronary catheter angiography. The promising results of the DSCT are due to a superior temporal resolution compared to the 64SCT. Confirmation of these data by trials in larger patient collectives is warranted.
引用
收藏
页码:295 / 300
页数:6
相关论文
共 50 条
  • [1] 64-slice CT angiography for the detection of coronary artery stenoses
    Carol Lovegrove
    Nature Clinical Practice Cardiovascular Medicine, 2006, 3 (1): : 7 - 7
  • [2] Identification and Characterization of Severe Coronary Artery Stenoses by Dual-Source 64-Slice Coronary Computed Tomography Angiography: Comparison with Invasive Coronary Angiography
    Wertman, Brett M.
    Cheng, Victor Y.
    Berg, Ryan A.
    Gransar, Heidi
    Kar, Saibal
    Schapira, Jay N.
    Berman, Daniel S.
    CIRCULATION, 2008, 118 (18) : S1062 - S1062
  • [3] Radiation dose for cardiac CT angiography - A comparison between dual source and 64-slice CT
    Hermann, Franziska
    Meyer, Tanja
    Hadamitzky, Martin
    Hendrich, Eva
    Lang, Ute
    Schwarzer, Christine
    Martinoff, Stefan
    Hausleiter, Joerg
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A142 - A142
  • [4] Visual and automatic grading of coronary artery stenoses with 64-slice CT angiography in reference to invasive angiography
    Stephanie Busch
    Thorsten R. C. Johnson
    Konstantin Nikolaou
    Franz von Ziegler
    Andreas Knez
    Maximilian F. Reiser
    Christoph R. Becker
    European Radiology, 2007, 17 : 1445 - 1451
  • [5] Visual and automatic grading of coronary artery stenoses with 64-slice CT angiography in reference to invasive angiography
    Busch, Stephanie
    Johnson, Thorsten R. C.
    Nikolaou, Konstantin
    von Ziegler, Franz
    Knez, Andreas
    Reiser, Maximilian F.
    Becker, Christoph R.
    EUROPEAN RADIOLOGY, 2007, 17 (06) : 1445 - 1451
  • [6] 64-slice CT: a comparison with invasive coronary angiography
    Ruth Kirby
    Nature Clinical Practice Cardiovascular Medicine, 2005, 2 (11): : 552 - 552
  • [7] Quantifizierung von Stenosen der Koronararterien64-Zeilen-CT-Angiographie und Dual Source vs. HerzkatheterQuantification of coronary artery stenosesComparison of 64-slice and dual source CT angiography with cardiac catheterization
    Stephanie Busch
    K. Nikolaou
    T. Johnson
    C. Rist
    A. Knez
    M. Reiser
    C. Becker
    Der Radiologe, 2007, 47 : 295 - 300
  • [8] Automated Quantification of Stenosis Severity on 64-Slice CT A Comparison With Quantitative Coronary Angiography
    Boogers, Mark J.
    Schuijf, Joanne D.
    Kitslaar, Pieter H.
    van Werkhoven, Jacob M.
    de Graaf, Fleur R.
    Boersma, Eric
    van Velzen, Joella E.
    Dijkstra, Jouke
    Adame, Isabel M.
    Kroft, Lucia J.
    de Roos, Albert
    Schreur, Joop H. M.
    Heijenbrok, Mark W.
    Jukema, J. Wouter
    Reiber, Johan H. C.
    Bax, Jeroen J.
    JACC-CARDIOVASCULAR IMAGING, 2010, 3 (07) : 699 - 709
  • [9] Diagnostic Value of 64-Slice Dual-Source CT Coronary Angiography in Patients with Atrial Fibrillation: Comparison with Invasive Coronary Angiography
    Zhang, Jian-Jun
    Liu, Tie
    Feng, Yue
    Wu, Wei-Feng
    Mou, Cai-Yun
    Zhai, Li-Hao
    KOREAN JOURNAL OF RADIOLOGY, 2011, 12 (04) : 416 - 423
  • [10] Cardiac CT angiography after coronary artery surgery in children using 64-slice CT scan
    Marini, Davide
    Agnoletti, Gabriella
    Brunelle, Francis
    Sidi, Daniel
    Bonnet, Damien
    Ou, Phalla
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (03) : 492 - 497