Primary Cementless Total Hip Arthroplasty with an Alumina Ceramic-on-Ceramic Bearing Results After a Minimum of Twenty Years of Follow-up

被引:62
|
作者
Petsatodis, George E. [1 ]
Papadopoulos, Pericles P. [1 ]
Papavasiliou, Kyriakos A. [1 ]
Hatzokos, Ippokratis G. [1 ]
Agathangelidis, Filon G. [1 ]
Christodoulou, Anastasios G. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Orthopaed Dept 1, G Papanikolaou Gen Hosp, Sch Med, Thessaloniki 57010, Greece
来源
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME | 2010年 / 92A卷 / 03期
关键词
YOUNG-PATIENTS; WEAR; DISLOCATION; STEM;
D O I
10.2106/JBJS.H.01829
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The biological problems related to wear debris after total hip arthroplasty have stimulated renewed interest in alternatives to meta I-on-polyethylene bearing surfaces. Methods: We retrospectively evaluated the clinical and radiographic results of 100 patients who had undergone a total of 109 primary total hip arthroplasties with a cementless alumina ceramic-on-ceramic prosthesis between January 1985 and December 1989. The mean age of the patients at the time of the index arthroplasty was forty-six years. Clinical evaluation was performed with use of the Charnley modification of the Merle d'Aubigne-Postel scale. Seventy-eight patients who had had a total of eighty-five arthroplasties were available for follow-up evaluation at an average of 20.8 years. The patients' average age at the time of the latest follow-up was 66.8 years. Results: Six hips (six acetabular cups and one femoral stem) in six patients underwent revision. Aseptic loosening of the cup combined with focal osteolysis was the cause of all six revisions. In one patient, the stem was also revised because of aseptic loosening. At the time of final follow-up, the result was excellent (according to the Merle d'Aubigne-Postel scale) in 68% of the hips, good in 19%, fair in 9%, and poor in 4%. The mean Merle d'Aubigne-Postel score improved from 7.9 points preoperatively to 16.9 points postoperatively (p < 0.001). The cumulative rate of survival of the prostheses was 84.4% at 20.8 years. Conclusions: The results of these cementless ceramic-on-ceramic total hip arthroplasties continued to be satisfactory at a minimum of twenty years postoperatively. The improved design of contemporary prostheses and the new generation of ceramic-on-ceramic bearing surfaces may lead to even better long-term results.
引用
收藏
页码:639 / 644
页数:6
相关论文
共 50 条
  • [1] Long-Term Results of Alumina Ceramic-On-Ceramic Bearings in Cementless Total Hip Arthroplasty: A 20-Year Minimum Follow-Up
    Xu, Joshua
    Oni, Tofunmi
    Shen, David
    Chai, Yuan
    Walter, William K.
    Walter, William L.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (03): : 549 - 553
  • [2] Nine years follow-up of 100 ceramic-on-ceramic total hip arthroplasty
    Chevillotte, Christophe
    Pibarot, Vincent
    Carret, Jean-Paul
    Bejui-Hugues, Jacques
    Guyen, Olivier
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (11) : 1599 - 1604
  • [3] Alumina ceramic-on-ceramic hybrid total hip arthroplasty. A median of 15 years follow-up
    Farhan-Alanie, Omer M. H.
    Hrycaiczuk, Alex
    Tinning, Craig
    Jones, Bryn
    Stark, Andrew
    Bryceland, Kevin
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (06): : 1127 - 1136
  • [4] Nine years follow-up of 100 ceramic-on-ceramic total hip arthroplasty
    Christophe Chevillotte
    Vincent Pibarot
    Jean-Paul Carret
    Jacques Bejui-Hugues
    Olivier Guyen
    International Orthopaedics, 2011, 35 : 1599 - 1604
  • [5] Alumina ceramic-on-ceramic hybrid total hip arthroplasty. A median of 15 years follow-up
    Omer M. H. Farhan-Alanie
    Alex Hrycaiczuk
    Craig Tinning
    Bryn Jones
    Andrew Stark
    Kevin Bryceland
    European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 1127 - 1136
  • [6] Eleven- to 14-year Follow-up Results of Cementless Total Hip Arthroplasty Using a Third-generation Alumina Ceramic-on-ceramic Bearing
    Sugano, Nobuhiko
    Takao, Masaki
    Sakai, Takashi
    Nishii, Takashi
    Miki, Hidenobu
    Ohzono, Kenji
    JOURNAL OF ARTHROPLASTY, 2012, 27 (05): : 736 - 741
  • [7] Results of revision of total hip arthroplasty for alumina ceramic-on-ceramic bearing fracture
    Trebse, Rihard
    Mihelic, Anze
    Levasic, Vesna
    Cor, Andrej
    Milosev, Ingrid
    HIP INTERNATIONAL, 2016, 26 (03) : 237 - 243
  • [8] Ceramic-on-Ceramic Total Hip Arthroplasty: Minimum of Six-Year Follow-up Study
    Choy, Won-Sik
    Kim, Kap Jung
    Lee, Sang Ki
    Bae, Kyoung Wan
    Hwang, Yoon Sub
    Park, Chang Kyu
    CLINICS IN ORTHOPEDIC SURGERY, 2013, 5 (03) : 174 - 179
  • [9] Ceramic-on-ceramic versus ceramic-on-polyethylene in total hip arthroplasty: a comparative study at a minimum of 13 years follow-up
    Malerba Giuseppe
    Basilico Mattia
    Bonfiglio Nadia
    Vitiello Raffaele
    Ruberto Pasquale
    D’ Adamio Stefano
    Sirgiovanni Mattia
    De Santis Vincenzo
    Maccauro Giulio
    BMC Musculoskeletal Disorders, 22
  • [10] Ceramic-on-ceramic versus ceramic-on-polyethylene in total hip arthroplasty: a comparative study at a minimum of 13 years follow-up
    Giuseppe, Malerba
    Mattia, Basilico
    Nadia, Bonfiglio
    Raffaele, Vitiello
    Pasquale, Ruberto
    Stefano, D' Adamio
    Mattia, Sirgiovanni
    Vincenzo, De Santis
    Giulio, Maccauro
    BMC MUSCULOSKELETAL DISORDERS, 2022, 22 (SUPPL 2)