SENSROC5: a 16-channel Radiation-Hardness Low-Noise Front-End ASIC Dedicated to CZT Detectors for X- and γ-Ray Imaging

被引:0
|
作者
Gao, W. [1 ]
Gao, D. [1 ]
Wei, T. [1 ]
Hu, Y. [2 ]
机构
[1] Northwestern Polytech Univ, Inst Microelect, Sch Comp Sci & Technol, Xian 710072, Shaanxi, Peoples R China
[2] Inst Pluridisciplinaire Hubert CURIEN, Strasbourg, France
基金
中国国家自然科学基金;
关键词
Low noise; Readout Circuits; ASIC; Front-End Electronics; X-ray and Gamma-ray imaging; READOUT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a low-noise front-end readout application specific integrated circuit (ASIC) for CZT detectors. A cascode amplifier based on split-let topology is selected to realize the charge-sensitive amplifier (CSA) to achieve low noise performances. A leakage-current-compensation circuit is added to suppress the leakage current of from 0 to 10 nA. The output of the CSA is connected to a slow shaper implemented by a CR(RC)(2) semi-Gaussian architecture. In the time branch, the CSA output is followed by a fast shaper for the trigger acquisition. A digital monostable circuits is designed to adjust the delay of trigger signals so that the peak value of the shaped voltages can be tracked. The sampled voltages are stored into an analog memory. Based on the above topology, a 16-channel front-end readout prototype chip (named as SENSROC5) is designed and implemented in 0.35 mu m CMOS process. In this chip, the radiation-hardness layout techniques are adopted. The die size is 2.12 mmx4.60 mm. The input range of the ASIC is from 2000 e-to 180000 e-, which is suitable for the detection of the X-and gamma ray from 11.2 keV to 1 MeV. The post-simulated results are listed in the following. The gain of the readout channel is 40.2 V/pC. The ENC is 90 e- at zero farad plus 15 e-per picofarad. The nonlinearity is less than 3 %. The crosstalk is less than 2 %. The power dissipation is about 16.5mWplus 3.1 mW/channel.
引用
收藏
页数:5
相关论文
共 17 条
  • [1] SENSROC4: An Multichannel Low-Noise Front-End Readout ASIC Dedicated to CZT Detectors for PET Imaging
    Gao, W.
    Liu, H.
    Gao, D.
    Gan, B.
    Wei, T.
    Hu, Y.
    2013 3RD INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION, MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2013,
  • [2] Design of a Multichannel Low-Noise Front-End Readout ASIC Dedicated to CZT Detectors for PET Imaging
    Gao, W.
    Liu, H.
    Gan, B.
    Wei, T.
    Gao, D.
    Hu, Y.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (05) : 2532 - 2539
  • [3] Linearity enhancement design of a 16-channel low-noise front-end readout ASIC for CdZnTe detectors
    Zeng, Huiming
    Wei, Tingcun
    Wang, Jia
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 847 : 93 - 98
  • [4] Design and and performance of a 16-channel radiation-hardened low-noise front-end readout ASIC for CZT-based hard X-ray imager
    Gao, W.
    Li, X.
    Liu, H.
    Hu, Y.
    MICROELECTRONICS JOURNAL, 2016, 48 : 87 - 94
  • [5] A low-noise 64-channel front-end readout ASIC for CdZnTe detectors aimed to hard X-ray imaging systems
    Gan, B.
    Wei, T.
    Gao, W.
    Liu, H.
    Hu, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 816 : 53 - 61
  • [6] Development of a CMOS low-noise analog front-end ASIC for X-ray imaging applications
    Zervakis, E
    Loukas, D
    Haralabidis, N
    Pavlidis, A
    PROCEEDINGS OF THE 2003 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL IV: DIGITAL SIGNAL PROCESSING-COMPUTER AIDED NETWORK DESIGN-ADVANCED TECHNOLOGY, 2003, : 764 - 767
  • [7] IDeF-X V1.0: A new 16-channel low-noise analog front-end for Cd(Zn)Te detectors
    Gevin, O.
    Lugiez, F.
    Limousin, O.
    Baron, P.
    Blondel, C.
    Coppolani, X.
    Dirks, B. P. F.
    Delagnes, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 567 (01): : 140 - 144
  • [8] Development of a compact radiation-hardened low-noise front-end readout ASIC for CZT-based hard X-ray imager
    Gao, W.
    Gan, B.
    Li, X.
    Wei, T.
    Gao, D.
    Hu, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 780 : 15 - 20
  • [9] Characteristics of a multichannel low-noise front-end ASIC for CZT-based small animal PET imaging
    Gao, W.
    Liu, H.
    Gan, B.
    Hu, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 745 : 57 - 62
  • [10] Design and Measurement of a Low-Noise 64-Channel Front-End Readout ASIC for CdZnTe Detectors
    Gan, B.
    Wei, T.
    Gao, W.
    Liu, H.
    Xue, F.
    Hu, Y.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,