Currently, research activities are underway to create coexistence between active implantable medical devices and Magnetic Resonance Imaging (MRI). One of the questions is if ferrite materials can be used for miniature transformers for EMI suppression. Commonly it is known that the use of magnetic materials should be minimized in and near an MRI scanner because MRI employs large magnetic fields with which any magnetic material will be subject to strong forces. In addition, magnetic materials may introduce image artifacts and reduce diagnostic image quality. The analysis presented in this paper shows that the requirements on diagnostic image quality pose higher limitations on the use of magnetic materials in medical implants than the requirements for magneto-mechanical forces. From experiments with ferrites in a 1.5-T MRI system, it is concluded that if diagnostic image quality is required for distances of at least 2 cm from the medical implant, then only 0.1 mm(3) ferrite can be accepted. This amount of ferrite is too low for any practical application. Therefore, medical implants can only be coexistent with MRI if they do not contain ferrites.
引用
收藏
页码:1463 / 1466
页数:4
相关论文
共 8 条
[1]  
ASTM International, 2006, F205206 ASTM
[2]   Endovascular interventional magnetic resonance imaging [J].
Bartels, LW ;
Bakker, CJG .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (14) :R37-R64
[3]   MAGNETIC RESONANCE IMAGING SUSCEPTIBILITY ARTIFACTS DUE TO METALLIC FOREIGN BODIES [J].
Hecht, Silke ;
Adams, William H. ;
Narak, Jill ;
Thomas, William B. .
VETERINARY RADIOLOGY & ULTRASOUND, 2011, 52 (04) :409-414
[4]  
Nyenhuis J., 2002, P IEEE INT S EL COMP, V2, P920
[5]   The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds [J].
Schenck, JF .
MEDICAL PHYSICS, 1996, 23 (06) :815-850
[6]  
Schueler BA, 1999, JMRI-J MAGN RESON IM, V9, P596, DOI 10.1002/(SICI)1522-2586(199904)9:4<596::AID-JMRI14>3.3.CO
[7]  
2-K
[8]  
Vlaardingerbroek M.T., 1999, Magnetic resonance imaging: theory and practice, V2nd