Optimization and validation of a method for the direct determination of catechin and epicatechin in red wines by HPLC/fluorescence

被引:38
|
作者
Dias, Fabio de Souza [1 ,2 ]
Palma Lovillo, Miguel [3 ,4 ]
Garcia Barroso, Carmelo [3 ,4 ]
David, Jorge Mauricio [1 ]
机构
[1] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
[2] Univ Fed Reconcavo Bahia, Ctr Ciencias Exatas & Tecnol, BR-44380000 Cruz Das Almas, BA, Brazil
[3] Univ Cadiz, Puerto Real, Spain
[4] Ctr Andaluz Invest Vitivinicolas, Puerto Real, Spain
关键词
Catechin; Epicatechin; Red wine; HPLC/fluorescence; ATOMIC-ABSORPTION-SPECTROMETRY; FLUORESCENCE DETECTION; ANTIOXIDANT ACTIVITY; RESVERATROL; POLYPHENOLS; SAMPLES; MANGANESE; ARRAY; IRON; HPLC;
D O I
10.1016/j.microc.2010.01.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present paper describes a direct procedure for the determination of catechin and epicatechin concentrations in red wines employing reverse-phase high performance liquid chromatography (RP HPLC) and detection by fluorescence. The method was performed using a sample volume of 10 mu L. without dilution. The separation process employed a Chromolith performance RP-18e (100 mm x 4.6 mm) column, and the mobile phase was composed of solvent A: methanol-acetic acid-water (90:8:2) and solvent B: water-acetic acid-methanol (10:2:88) at a flow rate of 1.0 mL min(-1). Linearity was observed in the range of 1 to 30 mg L(-1), with limits of detection and quantification of 0.27 and 0.89 mg L(-1), respectively, for catechin and 0.33 and 1.01 mg L(-1) respectively, for epicatechin. The precisions estimated by the relative standard deviation were 3.34 and 1.09% for catechin concentrations of 0.5 and 20 mg L(-1) respectively and 2.82 and 0.49% for epicatechin concentrations of 0.5 and 20 mg L(-1), respectively. The evaluation of the accuracy was done using an addition/recovery assay. Four wine samples were used, and the recoveries varied from 105 to 108% for catechin and from 97 to 119% for epicatechin. The method was applied to the analysis of red wine samples collected from the Sao Francisco region, Bahia State, Brazil. Nine samples were analyzed, and the catechin and epicatechin concentrations varied from 7.51 to 73.20 and from 5.08 to 43.32 mg L(-1), respectively. The concentrations found agree with data reported in the literature. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 20
页数:4
相关论文
共 50 条
  • [21] Multivariant optimization, validation, and application of capillary electrophoresis for simultaneous determination of polyphenols and phenolic acids in Brazilian wines
    Peres, Renato G.
    Micke, Gustavo A.
    Tavares, Marina F. M.
    Rodriguez-Amaya, Delia B.
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (21) : 3822 - 3828
  • [22] VALIDATION OF A HPLC METHOD FOR OCHRATOXIN A DETERMINATION
    Bulea, Delia
    Spac, A. F.
    Dorneanu, V.
    MEDICAL-SURGICAL JOURNAL-REVISTA MEDICO-CHIRURGICALA, 2011, 115 (02): : 595 - 600
  • [23] Determination of antioxidant power of red and white wines by a new electrochemical method and its correlation with polyphenolic content
    Alonso, AM
    Domínguez, C
    Guillén, DA
    Barroso, CG
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (11) : 3112 - 3115
  • [24] Determination of anthocyanins and related components in red wines by micro- and capillary HPLC
    Dugo, P
    Favoino, O
    Lo Presti, M
    Luppino, R
    Dugo, G
    Mondello, L
    JOURNAL OF SEPARATION SCIENCE, 2004, 27 (17-18) : 1458 - 1466
  • [25] DIRECT HPLC ANALYSIS OF CIS-RESVERATROL AND TRANS-RESVERATROL AND PICEID ISOMERS IN SPANISH RED VITIS-VINIFERA WINES
    LAMUELARAVENTOS, RM
    ROMEROPEREZ, AI
    WATERHOUSE, AL
    DELATORREBORONAT, MC
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1995, 43 (02) : 281 - 283
  • [26] Validation of a liquid chromatography method for the simultaneous quantification of ochratoxin A and its analogues in red wines
    Remiro, Rebeca
    Ibanez-Vea, Maria
    Gonzalez-Penas, Elena
    Lizarraga, Elena
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (52) : 8249 - 8256
  • [27] Development and validation of a rapid HPLC method for the direct determination of colchicine in pharmaceuticals and biological fluids
    Samanidou, VF
    Sarantis, GA
    Papadoyannis, IN
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (01) : 1 - 13
  • [28] Method development for determination of (+)-catechin and (-)-epicatechin by micellar electrokinetic chromatography: Annual characterization of field grown blackberries
    Piovezan, Marcel
    Garcia-Seco, Daniel
    Micke, Gustavo Amadeu
    Gutierrez-Manero, Javier
    Ramos-Solano, Beatriz
    ELECTROPHORESIS, 2013, 34 (15) : 2251 - 2258
  • [29] Optimization and validation of an SBSE-HPLC-FD method using laboratory-made stir bars for fluoxetine determination in human plasma
    Marques, Leticia Aparecida
    Nakahara, Thais Tiemi
    Madeira, Tiago Bervelieri
    Almeida, Mariana Bortholazzi
    Monteiro, Alessandra Maffei
    Silva, Maria de Almeida
    Carrilho, Emanuel
    Piccoli de Melo, Luiz Gustavo
    Nixdorf, Suzana Lucy
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (01)
  • [30] Method for the Determination of Catechin and Epicatechin Enantiomers in Cocoa-Based Ingredients and Products by High-Performance Liquid Chromatography: Single-Laboratory Validation
    Machonis, Philip R.
    Jones, Matthew A.
    Schaneberg, Brian T.
    Kwik-Uribe, Catherine L.