Optimization and validation of a method for the direct determination of catechin and epicatechin in red wines by HPLC/fluorescence

被引:38
|
作者
Dias, Fabio de Souza [1 ,2 ]
Palma Lovillo, Miguel [3 ,4 ]
Garcia Barroso, Carmelo [3 ,4 ]
David, Jorge Mauricio [1 ]
机构
[1] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
[2] Univ Fed Reconcavo Bahia, Ctr Ciencias Exatas & Tecnol, BR-44380000 Cruz Das Almas, BA, Brazil
[3] Univ Cadiz, Puerto Real, Spain
[4] Ctr Andaluz Invest Vitivinicolas, Puerto Real, Spain
关键词
Catechin; Epicatechin; Red wine; HPLC/fluorescence; ATOMIC-ABSORPTION-SPECTROMETRY; FLUORESCENCE DETECTION; ANTIOXIDANT ACTIVITY; RESVERATROL; POLYPHENOLS; SAMPLES; MANGANESE; ARRAY; IRON; HPLC;
D O I
10.1016/j.microc.2010.01.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present paper describes a direct procedure for the determination of catechin and epicatechin concentrations in red wines employing reverse-phase high performance liquid chromatography (RP HPLC) and detection by fluorescence. The method was performed using a sample volume of 10 mu L. without dilution. The separation process employed a Chromolith performance RP-18e (100 mm x 4.6 mm) column, and the mobile phase was composed of solvent A: methanol-acetic acid-water (90:8:2) and solvent B: water-acetic acid-methanol (10:2:88) at a flow rate of 1.0 mL min(-1). Linearity was observed in the range of 1 to 30 mg L(-1), with limits of detection and quantification of 0.27 and 0.89 mg L(-1), respectively, for catechin and 0.33 and 1.01 mg L(-1) respectively, for epicatechin. The precisions estimated by the relative standard deviation were 3.34 and 1.09% for catechin concentrations of 0.5 and 20 mg L(-1) respectively and 2.82 and 0.49% for epicatechin concentrations of 0.5 and 20 mg L(-1), respectively. The evaluation of the accuracy was done using an addition/recovery assay. Four wine samples were used, and the recoveries varied from 105 to 108% for catechin and from 97 to 119% for epicatechin. The method was applied to the analysis of red wine samples collected from the Sao Francisco region, Bahia State, Brazil. Nine samples were analyzed, and the catechin and epicatechin concentrations varied from 7.51 to 73.20 and from 5.08 to 43.32 mg L(-1), respectively. The concentrations found agree with data reported in the literature. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 20
页数:4
相关论文
共 50 条
  • [11] METHOD OF SEPARATION OF ANTHOCYANINS IN RED WINES BY HPLC
    DRDAK, M
    DAUCIK, P
    SIMKO, P
    KAROVICOVA, J
    RAJNIAKOVA, A
    NAHRUNG-FOOD, 1992, 36 (04): : 411 - 413
  • [12] Development and validation of a LC-method for determination of catechin and epicatechin in aqueous extractives from leaves of Maytenus ilicifolia
    Soares, LAL
    Oliveira, AL
    Ortega, GG
    Petrovick, PR
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (04) : 787 - 790
  • [13] A validated solid-phase extraction HPLC method for the simultaneous determination of gallic acid, catechin and epicatechin in rhubarb decoction
    Song Rui
    Cheng Ying
    Tian Yuan
    Zhang Zun-Jian
    CHINESE JOURNAL OF NATURAL MEDICINES, 2012, 10 (04): : 275 - 278
  • [14] Optimization of the Number of Considered Conformers for the Absolute Configuration Determination of Catechin and Epicatechin Peracetates by VCD
    Burgueno-Tapia, Eleuterio
    Sanchez-Castellanos, Mariano
    Joseph-Nathan, Pedro
    NATURAL PRODUCT COMMUNICATIONS, 2017, 12 (05) : 683 - 686
  • [15] Optimization and Validation of a Method to Determine Enolones and Vanillin Derivatives in Wines-Occurrence in Spanish Red Wines and Mistelles
    Bueno, Monica
    Zapata, Julian
    Cullere, Laura
    Franco-Luesma, Ernesto
    de-la-Fuente-Blanco, Arancha
    Ferreira, Vicente
    MOLECULES, 2023, 28 (10):
  • [16] HPLC coupled with fluorescence detection for the determination of procyanidins in white wines
    Carando, S
    Teissedre, PL
    Cabanis, JC
    CHROMATOGRAPHIA, 1999, 50 (3-4) : 253 - 254
  • [17] HPLC coupled with fluorescence detection for the determination of procyanidins in white wines
    S. Carando
    P. L. Teissedre
    J. C. Cabanis
    Chromatographia, 1999, 50 : 253 - 254
  • [18] HPLC coupled with fluorescence detection for the determination of procyanidins in white wines
    Laboratoire de Chimie Analytique, Faculté de Pharmacie, Avenue Charles Flahault, 34060 Montpellier, France
    Chromatographia, 3-4 (253-254):
  • [19] Development and validation of an HPLC method for the determination of epicatechin in Maytenus ilicifolia (Schrad.) Planch., Celastraceae
    Lopes, Gisely Cristiny
    Blainski, Andressa
    Pires dos Santos, Paulo Victor
    Diciaula, Maria Cristina
    Palazzo de Mello, Joao Carlos
    REVISTA BRASILEIRA DE FARMACOGNOSIA-BRAZILIAN JOURNAL OF PHARMACOGNOSY, 2010, 20 (05): : 789 - 795
  • [20] Optimization and Validation of a Fluorescence Method for the Determination of Primaquine in Pharmaceutical Formulation
    Altigani, Aida Makram Nouralla
    Elbashir, Abdalla Ahmed
    Aboul-Enein, Hassan Y.
    CURRENT ANALYTICAL CHEMISTRY, 2018, 14 (01) : 30 - 35