Optimization and validation of a method for the direct determination of catechin and epicatechin in red wines by HPLC/fluorescence

被引:38
|
作者
Dias, Fabio de Souza [1 ,2 ]
Palma Lovillo, Miguel [3 ,4 ]
Garcia Barroso, Carmelo [3 ,4 ]
David, Jorge Mauricio [1 ]
机构
[1] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
[2] Univ Fed Reconcavo Bahia, Ctr Ciencias Exatas & Tecnol, BR-44380000 Cruz Das Almas, BA, Brazil
[3] Univ Cadiz, Puerto Real, Spain
[4] Ctr Andaluz Invest Vitivinicolas, Puerto Real, Spain
关键词
Catechin; Epicatechin; Red wine; HPLC/fluorescence; ATOMIC-ABSORPTION-SPECTROMETRY; FLUORESCENCE DETECTION; ANTIOXIDANT ACTIVITY; RESVERATROL; POLYPHENOLS; SAMPLES; MANGANESE; ARRAY; IRON; HPLC;
D O I
10.1016/j.microc.2010.01.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present paper describes a direct procedure for the determination of catechin and epicatechin concentrations in red wines employing reverse-phase high performance liquid chromatography (RP HPLC) and detection by fluorescence. The method was performed using a sample volume of 10 mu L. without dilution. The separation process employed a Chromolith performance RP-18e (100 mm x 4.6 mm) column, and the mobile phase was composed of solvent A: methanol-acetic acid-water (90:8:2) and solvent B: water-acetic acid-methanol (10:2:88) at a flow rate of 1.0 mL min(-1). Linearity was observed in the range of 1 to 30 mg L(-1), with limits of detection and quantification of 0.27 and 0.89 mg L(-1), respectively, for catechin and 0.33 and 1.01 mg L(-1) respectively, for epicatechin. The precisions estimated by the relative standard deviation were 3.34 and 1.09% for catechin concentrations of 0.5 and 20 mg L(-1) respectively and 2.82 and 0.49% for epicatechin concentrations of 0.5 and 20 mg L(-1), respectively. The evaluation of the accuracy was done using an addition/recovery assay. Four wine samples were used, and the recoveries varied from 105 to 108% for catechin and from 97 to 119% for epicatechin. The method was applied to the analysis of red wine samples collected from the Sao Francisco region, Bahia State, Brazil. Nine samples were analyzed, and the catechin and epicatechin concentrations varied from 7.51 to 73.20 and from 5.08 to 43.32 mg L(-1), respectively. The concentrations found agree with data reported in the literature. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 20
页数:4
相关论文
共 50 条
  • [1] Catechin-Molecularly Imprinted Cryogel for Determination of Catechin in Red Wines by HPLC-DAD-Fluorescence Detector
    Buyuktuncel, Ebru
    Porgali, Esra
    Ozkara, Serpil
    ACTA CHROMATOGRAPHICA, 2018, 30 (01) : 54 - 61
  • [2] An industry consensus study on an HPLC fluorescence method for the determination of (±)-catechin and (±)-epicatechin in cocoa and chocolate products
    Shumow, Laura
    Bodor, Alison
    CHEMISTRY CENTRAL JOURNAL, 2011, 5
  • [3] An industry consensus study on an HPLC fluorescence method for the determination of (±)-catechin and (±)-epicatechin in cocoa and chocolate products
    Laura Shumow
    Alison Bodor
    Chemistry Central Journal, 5
  • [4] Optimization and validation of the direct HPLC method for the determination of moxifloxacin in plasma
    Laban-Djurdjevic, Aleksandra
    Jelikic-Stankov, Milena
    Djurdjevic, Predrag
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 844 (01): : 104 - 111
  • [5] Catechin and epicatechin concentrations of red wines: Regional and cultivar-related differences
    Goldberg, DM
    Karumanchiri, A
    Tsang, E
    Soleas, GJ
    AMERICAN JOURNAL OF ENOLOGY AND VITICULTURE, 1998, 49 (01): : 23 - 34
  • [6] Biogenic amine content of red Spanish wines:: comparison of a direct ELISA and an HPLC method for the determination of histamine in wines
    Marcobal, A
    Polo, MC
    Martín-Alvarez, PJ
    Moreno-Arribas, MV
    FOOD RESEARCH INTERNATIONAL, 2005, 38 (04) : 387 - 394
  • [7] DETERMINATION OF THE UNPERTURBED DIMENSIONS OF POLYMERS OF (+)-CATECHIN AND (-)-EPICATECHIN - THE ROLE OF FLUORESCENCE
    MATTICE, WL
    ADVANCES IN CHEMISTRY SERIES, 1989, (223): : 285 - 293
  • [8] Optimization and Validation of a New Capillary Electrophoresis Method with Conductivity Detection for Determination of Small Anions in Red Wines
    Zorica Lelova
    Violeta Ivanova-Petropulos
    Marián Masár
    Klemen Lisjak
    Róbert Bodor
    Food Analytical Methods, 2018, 11 : 1457 - 1466
  • [9] Optimization and Validation of a New Capillary Electrophoresis Method with Conductivity Detection for Determination of Small Anions in Red Wines
    Lelova, Zorica
    Ivanova-Petropulos, Violeta
    Masar, Marian
    Lisjak, Klemen
    Bodor, Robert
    FOOD ANALYTICAL METHODS, 2018, 11 (05) : 1457 - 1466
  • [10] TARTARIC ACID IN FROZEN MUSTS AND WINES - OPTIMIZATION OF REBELEIN METHOD AND VALIDATION BY HPLC
    ALMELA, L
    LAZARO, I
    LOPEZROCA, JM
    FERNANDEZLOPEZ, JA
    FOOD CHEMISTRY, 1993, 47 (04) : 357 - 361