Design and Quantitative Analysis of Cancer Detection System Based on Fluorescence Immune Analysis

被引:4
|
作者
Shao, Lei [1 ]
Zhang, Longyu [1 ]
Li, Shilin [2 ]
Zhang, Pengyuan [3 ]
机构
[1] Tianjin Univ Technol, Tianjin Key Lab Control Theory & Applicat Complic, Tianjin 300384, Peoples R China
[2] Tianjin Xinuo Biomed Co Ltd, Tianjin, Peoples R China
[3] Tianjin Yirui Biotechnol Co Ltd, Tianjin, Peoples R China
关键词
QUANTUM DOTS; ALGORITHM;
D O I
10.1155/2019/1672940
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Human blood is an important medical detection index. With the development in clinical medical detection instruments and detection technology, the requirements for detection accuracy and efficiency have been gradually improved. Fluorescent immunochromatography is a new detection technique. It has the characteristics of high efficiency, convenience, no pollution, and wide detection range. Human blood can be detected quickly using fluorescent immunochromatography. At present, it has received great attention from the field of clinical testing. In this paper, a set of fluorescent immunochromatographic analyzer has been designed. It is mainly based on the principle of fluorescence immunochromatography. A new method of signal analysis and system design for fluorescent immunochromatography analyzer is proposed. By using the improved threshold function denoising algorithm, the quantitative detection of fluorescent immunochromatographic strip is realized. The concentration of pathogenic factors (cancer cells) in human serum can be measured conveniently and accurately. The system integrates many peripheral modules, including fluorescence signal acquisition, fluorescence signal processing, quantitative curve fitting, and test results. In this paper, the quantitative detection experiments of the system are carried out in three aspects: linearity, repeatability, and sensitivity. The experimental results show that the linear correlation coefficient is up to 0.9976, and the limit of detection is up to 0.05 ng/ml. The requirements of the system are satisfied. The system performance is good, and the quantitative result is accurate. Therefore, the establishment of a fluorescence analysis system is of great significance.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] A New Optical Method for Quantitative Detection of Microplastics in Water Based on Real-Time Fluorescence Analysis
    Nicolai, Eleonora
    Pizzoferrato, Roberto
    Li, Yuliu
    Frattegiani, Simona
    Nucara, Alessandro
    Costa, Giulia
    WATER, 2022, 14 (20)
  • [32] Analysis of dysregulation of immune system in pancreatic cancer based on gene expression profile
    Wang, Baosheng
    Sun, Shaolong
    Liu, Zhen
    MOLECULAR BIOLOGY REPORTS, 2014, 41 (07) : 4361 - 4367
  • [33] Analysis of dysregulation of immune system in pancreatic cancer based on gene expression profile
    Baosheng Wang
    Shaolong Sun
    Zhen Liu
    Molecular Biology Reports, 2014, 41 : 4361 - 4367
  • [34] QUANTITATIVE FLUORESCENCE IMAGE-ANALYSIS IN THE DIAGNOSIS OF LUNG-CANCER
    GASBARRA, D
    BASS, B
    LEVIN, D
    GRODE, T
    HEMSTREET, G
    HONKER, N
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1986, 133 (04): : A287 - A287
  • [35] Quantitative analysis of phosphorylation-based protein signaling networks in the immune system by mass spectrometry
    Nita-Lazar, Aleksandra
    WILEY INTERDISCIPLINARY REVIEWS-SYSTEMS BIOLOGY AND MEDICINE, 2011, 3 (03) : 368 - 376
  • [36] A Mobile-based Image Analysis System for Cervical Cancer Detection
    Monsur, Saka Abiola
    Adeshina, Steve A.
    Sud, Shivani
    Soboyejo, Winston O.
    2017 13TH INTERNATIONAL CONFERENCE ON ELECTRONICS, COMPUTER AND COMPUTATION (ICECCO), 2017,
  • [37] QUANTITATIVE FLUORESCENCE IMAGE-ANALYSIS IN BLADDER-CANCER SCREENING
    HEMSTREET, GP
    HURST, RE
    BASS, RA
    RAO, JY
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1990, 32 (09) : 822 - 828
  • [38] Design and Analysis for Fall Detection System Simplification
    Martinez-Villasenor, Lourdes
    Ponce, Hiram
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (158):
  • [39] A SEMI-QUANTITATIVE X-RAY FLUORESCENCE ANALYSIS SYSTEM
    HEINRICH, KFJ
    SPECTROCHIMICA ACTA, 1962, 18 (06): : 887 - 887
  • [40] Microdialysis: Fluorescence analysis system for vancomycin detection in pharmaceuticals and plasma
    Mu, Fangya
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258