High-field MR imaging in pediatric congenital heart disease: Initial results

被引:11
|
作者
Nguyen, Kim-Lien [1 ]
Khan, Sarah N. [2 ]
Moriarty, John M. [2 ]
Mohajer, Kiyarash [2 ]
Renella, Pierangelo [2 ]
Satou, Gary [3 ]
Ayad, Ihab [4 ]
Patel, Swati [4 ]
Boechat, M. Ines [2 ]
Finn, J. Paul [2 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Div Cardiol, VA Greater Los Angeles Healthcare Syst, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Radiol Sci, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Div Pediat Cardiol, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, David Geffen Sch Med, Dept Anesthesia, Los Angeles, CA 90095 USA
关键词
Magnetic resonance imaging; Magnetic resonance angiography; 3.0; Tesla; Congenital heart disease; Cardiovascular; Neonate; Children; TO-NOISE RATIO; CARDIOVASCULAR MAGNETIC-RESONANCE; TECHNICAL CONSIDERATIONS; SPATIAL-RESOLUTION; CLINICAL-PRACTICE; 3.0; TESLA; ANGIOGRAPHY; INFANTS; CHALLENGES; CHILDREN;
D O I
10.1007/s00247-014-3093-y
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Comprehensive assessment of pediatric congenital heart disease (CHD) at any field strength mandates evaluation of both vascular and dynamic cardiac anatomy for which diagnostic quality contrast-enhanced magnetic resonance angiography (CEMRA) and cardiac cine are crucial. To determine whether high-resolution (HR) CEMRA and steady-state free precession (SSFP) cine can be performed reliably at 3.0 T in children with CHD and to compare the image quality to similar techniques performed at 1.5 T. Twenty-eight patients with a median age of 5 months and average weight 9.0 +/- 7.8 kg with suspected or known CHD were evaluated at 3.0 T. SSFP cine (n = 86 series) and HR-CEMRA (n = 414 named vascular segments) were performed and images were scored for image quality and artifacts. The findings were compared to those of 28 patients with CHD of similar weight who were evaluated at 1.5 T. Overall image quality on HR-CEMRA was rated as excellent or good in 96% (397/414) of vascular segments at 3.0 T (k = 0.49) and in 94% (349/371) of vascular segments at 1.5 T (k = 0.36). Overall image quality of SSFP was rated excellent or good in 91% (78/86) of cine series at 3.0 T (k = 0.55) and in 81% (87/108) at 1.5 T (k = 0.47). Off-resonance artifact was common at both field strengths, varied over the cardiac cycle and was more prevalent at 3.0 T. At 3.0 T, off-resonance dark band artifact on SSFP cine was absent in 3% (3/86), mild in 69% (59/86), moderate in 27% (23/86) and severe in 1% (1/86) of images; at 1.5 T, dark band artifact was absent in 16% (17/108), mild in 69% (75/108), moderate in 12% (13/108) and severe in 3% (3/108) of cine images. The signal-to-noise ratio and contrast-to-noise ratio of both SSFP cine and HR-CEMRA images were significantly higher at 3.0 T than at 1.5 T (P < 0.001). Signal-to-noise ratio and contrast-to-noise ratio of high-resolution contrast-enhanced magnetic resonance angiography and SSFP cine were higher at 3.0 T than at 1.5 T. Artifacts on SSFP cine were cardiac phase specific and more prevalent at 3.0 T such that frequency-tuning was required in one-third of exams. In neonates, high spatial resolution CEMRA was highly reliable in defining extracardiac vascular anatomy.
引用
收藏
页码:42 / 54
页数:13
相关论文
共 50 条
  • [1] High-field MR imaging in pediatric congenital heart disease: Initial results
    Kim-Lien Nguyen
    Sarah N. Khan
    John M. Moriarty
    Kiyarash Mohajer
    Pierangelo Renella
    Gary Satou
    Ihab Ayad
    Swati Patel
    M. Ines Boechat
    J. Paul Finn
    Pediatric Radiology, 2015, 45 : 42 - 54
  • [2] Pediatric High-Field Magnetic Resonance Imaging
    Dahmoush, Hisham M.
    Vossough, Arastoo
    Roberts, Timothy P. L.
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2012, 22 (02) : 297 - +
  • [3] Computed tomography for imaging of pediatric congenital heart disease
    Glaser-Gallion, N.
    Stinn, B.
    Alkadhi, H.
    Lell, M.
    Goo, H. W.
    Paul, J-F
    Wildermuth, S.
    Leschka, S.
    RADIOLOGE, 2011, 51 (01): : 38 - 43
  • [4] Safety and Imaging Quality of MRI in Pediatric and Adult Congenital Heart Disease Patients with Pacemakers
    Pulver, Aaron F.
    Puchalski, Michael D.
    Bradley, David J.
    Minich, L. Luann
    Su, Jason T.
    Saarel, Elizabeth V.
    Whitaker, Patricia
    Etheridge, Susan P.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (04): : 450 - 456
  • [5] Imaging of pediatric congenital heart disease
    Tonkin, IL
    JOURNAL OF THORACIC IMAGING, 2000, 15 (04) : 274 - 279
  • [6] Computed Tomography and Other Imaging Modalities in Pediatric Congenital Heart Disease
    Chen, Hongying
    Bahari, Norafida
    Saini, Suraini Mohamad
    Noor, Noramaliza Mohd
    PERTANIKA JOURNAL OF SCIENCE AND TECHNOLOGY, 2022, 30 (04): : 2439 - 2462
  • [7] MR and cine-MR imaging in the diagnosis of infantile congenital heart disease
    Zhu, HY
    Han, LX
    Huang, XH
    Wang, X
    CHINESE MEDICAL JOURNAL, 2001, 114 (04) : 360 - 363
  • [8] Advances in MR Imaging Assessment of Adults with Congenital Heart Disease
    Kathiria, Nazima N.
    Higgins, Charles B.
    Ordovas, Karen G.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2015, 23 (01) : 35 - +
  • [9] Imaging of congenital heart disease in adults
    Babu-Narayan, Sonya V.
    Giannakoulas, George
    Valente, Anne Marie
    Li, Wei
    Gatzoulis, Michael A.
    EUROPEAN HEART JOURNAL, 2016, 37 (15) : 1182 - 1195
  • [10] Imaging Modalities in Congenital Heart Disease
    Sachdeva, Sakshi
    Gupta, Saurabh Kumar
    INDIAN JOURNAL OF PEDIATRICS, 2020, 87 (05) : 385 - 397