Four various biosensors based on flow enzymatic mini-reactors containing one of the two different mesoporous silica powders (SBA-15 or MCM-41) modified by one of the two enzymes (laccase or tyrosinase) were used for the determination of L-DOPA, dopamine, noradrenaline, and adrenaline. Dependences of peak currents on detection potentials, flow rates, injected volumes, reactor volumes, and analyte concentrations were studied and optimized. The silica powder of MCM-41 with covalently bonded laccase (Lac) was found to be the best filling for the detection of catecholamines. Relative current response of such biosensor was: 100% for dopamine, 32.1% for L-DOPA, 26.2% for noradrenaline, and 0.71% for adrenaline. Statistical evaluation of parallel determinations of studied analytes with this biosensor proved its good accuracy (RSD=1.82-5.18%) and sensitivity (5.46-15.5molL(-1)). Life time of the studied biosensors is several months. The practical applicability of Lac-MCM41 biosensor was successfully verified by the determination of dopamine and noradrenaline in medical solutions for infusions.
引用
收藏
页码:1163 / 1171
页数:9
相关论文
共 37 条
[1]   Review of Pediatric Pheochromocytoma and Paraganglioma [J].
Bholah, Reshma ;
Bunchman, Timothy Edward .
FRONTIERS IN PEDIATRICS, 2017, 5
[2]   Liquid chromatographic methods for the quantification of catecholamines and their metabolites in several biological samples-A review [J].
Bicker, Joana ;
Fortuna, Ana ;
Alves, Gilberto ;
Falcao, Amilcar .
ANALYTICA CHIMICA ACTA, 2013, 768 :12-34
[3]   Amperometric flow-injection determination of phenolic compounds at self-assembled monolayer-based tyrosinase biosensors [J].
Campuzano, S ;
Serra, B ;
Pedrero, M ;
de Villena, FJM ;
Pingarrón, JM .
ANALYTICA CHIMICA ACTA, 2003, 494 (1-2) :187-197
[4]   Detection of trace phenol based on mesoporous silica derived tyrosinase-peroxidase biosensor [J].
Dai, ZH ;
Xu, XX ;
Wu, L ;
Ju, HX .
ELECTROANALYSIS, 2005, 17 (17) :1571-1577
[5]   Flow-through tyrosinase enzyme reactor based on reticulated vitreous carbon functionalized by an electrochemically synthesized film [J].
DeBenedetto, GE ;
Palmisano, F ;
Zambonin, PG .
ANALYTICA CHIMICA ACTA, 1996, 326 (1-3) :149-154
[6]   IMMOBILIZATION OF PROTEINS ON GOLD COATED POROUS MEMBRANES VIA AN ACTIVATED SELF-ASSEMBLED MONOLAYER OF THIOCTIC ACID [J].
DUAN, CM ;
MEYERHOFF, ME .
MIKROCHIMICA ACTA, 1995, 117 (3-4) :195-206
[7]   Ageing changes the cellular basis of the "fight-or-flight" response in human adrenal chromaffin cells [J].
Elhamdani, A ;
Palfrey, CH ;
Artalejo, CR .
NEUROBIOLOGY OF AGING, 2002, 23 (02) :287-293
[8]   Norepinephrine Deficiency in Parkinson's Disease: The Case for Noradrenergic Enhancement [J].
Espay, Alberto J. ;
LeWitt, Peter A. ;
Kaufmann, Horacio .
MOVEMENT DISORDERS, 2014, 29 (14) :1710-1719
[9]   Electrochemical estimation of the polyphenol index in wines using a laccase biosensor [J].
Gamella, M. ;
Campuzano, S. ;
Reviejo, A. J. ;
Pingarron, J. M. .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (21) :7960-7967
[10]   Serotonin and catecholamines in the development and progression of heart valve diseases [J].
Goldberg, Elliott ;
Grau, Juan B. ;
Fortier, Jacqueline H. ;
Salvati, Elisa ;
Levy, Robert J. ;
Ferrari, Giovanni .
CARDIOVASCULAR RESEARCH, 2017, 113 (08) :849-857