Amperometric biosensor for formic acid in air

被引:26
|
作者
Sandström, KJM
Newman, J
Sunesson, AL
Levin, JO
Turner, APF
机构
[1] Natl Inst Working Life, Dept Chem, S-90713 Umea, Sweden
[2] Umea Univ, Dept Publ Hlth & Clin Med, S-90581 Umea, Sweden
[3] Cranfield Univ, Cranfield Biotechnol Ctr, Cranfield MK43 0AL, Beds, England
关键词
biosensor; air monitoring; formic acid; gas-permeable membrane; glycerol;
D O I
10.1016/S0925-4005(00)00566-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The possibility of developing a simple, inexpensive and specific personal passive "real-time" air sampler incorporating a biosensor for formic acid was investigated. The sensor is based on the enzymatic reaction between formic acid and formate dehydrogenase (FDH) with nicotinamide adenine dinucleotide (NAD(+)) as a co-factor and Meldola's blue as mediator. An effective way to immobilise the enzyme, co-factor and Meldola's blue on screen-printed, disposable, electrodes was found to be in a mixture of glycerol and phosphate buffer covered with a gas-permeable membrane. Steady-state current was reached after 4-15 min and the limit of detection was calculated to be below 1 mg/m(3). However, the response decreased by 50% after storage at -15 degreesC for 1 day. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:182 / 187
页数:6
相关论文
共 50 条
  • [1] AMPEROMETRIC TITRATION OF FORMALDEHYDE AND FORMIC ACID
    USVYATSO.AA
    SOLOMATI.VT
    INDUSTRIAL LABORATORY, 1970, 36 (02): : 205 - &
  • [2] Multivariate evaluation of factors influencing the performance of a formic acid biosensor for use in air monitoring
    Sandström, KJM
    Carlson, R
    Sunesson, AL
    Levin, JO
    Turner, APF
    ANALYST, 2001, 126 (11) : 2008 - 2014
  • [3] Prototype amperometric biosensor for sialic acid determination
    Marzouk, Sayed A. M.
    Ashraf, S. S.
    Al Tayyari, Khawla A.
    ANALYTICAL CHEMISTRY, 2007, 79 (04) : 1668 - 1674
  • [4] Determination of uric acid in serum by a mediated amperometric biosensor
    Tsai, WC
    Wen, ST
    ANALYTICAL LETTERS, 2006, 39 (05) : 891 - 901
  • [5] Quantification of lactic acid in wines using an amperometric biosensor
    Piedra, Felipe Jadan
    Yanos, Christian M. Villavicencio
    Mieles, Jenifer Mieles
    Macias, Manuel Cantos
    Loor, Andres Miguel Anchundia
    Velez, Maria Isabel Zambrano
    Flor, Frank Guillermo Intriago
    Intriago, Sonia Nathaly Giler
    Vega, Efrain Perez
    Velasquez, Rosa Mariuxi Litardo
    Jadan-Piedra, Carlos
    FOOD CONTROL, 2025, 167
  • [6] An Amperometric Biosensor for the Determination of Lactic Acid During Malolactic Fermentation
    Sannini, Adriana
    Albanese, Donatella
    Malvano, Francesca
    Crescitelli, Alessio
    Di Matteo, Marisa
    FRUTIC ITALY 2015: 9TH NUT AND VEGETABLE PRODUCTION ENGINEERING SYMPOSIUM, 2015, 44 : 283 - 288
  • [7] Ferroceneboronic acid-based amperometric biosensor for glycated hemoglobin
    Liu, SQ
    Wollenberger, U
    Katterle, M
    Scheller, FW
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (02) : 623 - 629
  • [8] Amperometric biosensor for urea
    Ha, KS
    Seo, ML
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 1997, 18 (11) : 1149 - 1152
  • [9] Amperometric glyceride biosensor
    Laurinavicius, V
    Kurtinaitiene, B
    Gureviciene, V
    Boguslavsky, L
    Geng, L
    Skotheim, T
    ANALYTICA CHIMICA ACTA, 1996, 330 (2-3) : 159 - 166
  • [10] ANALYSIS OF FORMIC-ACID IN AIR SAMPLES
    SMALLWOOD, AW
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1978, 39 (02): : 151 - 153