摘要
This paper presents experimental investigations about the fire behaviour of GFRP pultruded columns with square tubular cross-section. The objectives of the study were to evaluate (i) the efficacy of passive (calcium silicate (CS) boards) and active (water-cooling) systems in providing fire protection to GFRP pultruded columns; and the effects of (ii) the number of sides exposed to fire; and (iii) the service load level on the GFRP columns' fire response. To this end, fire resistance tests were performed on 1.5 m long GFRP columns, subjected to two different load levels corresponding to axial shortenings of L/1500 and L/750 (L being the span), and simultaneously exposed to fire, in either one or three sides, according to the time-temperature curve defined in ISO 834. Results obtained were analysed regarding the thermal and mechanical responses of the GFRP columns (unprotected and protected), namely in terms of the evolution of axial and transverse displacements, the failure modes and the fire resistance. It was possible to conclude that for one-side exposure, water-cooling is the most effective protection, particularly with flowing water, providing more than 120 min of fire resistance. For three-sides exposure, the fire resistance of the different solutions tested was severely reduced, namely that of the water-cooling systems, which provided fire resistances of only about 20 min, regardless of using flowing water; for this type of exposure, the best performance was provided by the CS board protection, with about 40 min of fire resistance. The results obtained in this study draw the attention to the technical advantages of adopting a building architecture in which the GFRP columns are integrated in the facades and embedded in partition walls, preventing the columns from being exposed to fire in three sides. As expected, the load level increase caused a reduction of fire resistance, due to the higher stresses developed in the sections' walls and to the GFRP strength decrease with temperature. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:201 / 211
页数:11
相关论文
共 50 条
  • [41] Experimental investigation of the fatigue behavior of adhesively-bonded pultruded GFRP joints under different load ratios
    Sarfaraz, Roohollah
    Vassilopoulos, Anastasios P.
    Keller, Thomas
    INTERNATIONAL JOURNAL OF FATIGUE, 2011, 33 (11) : 1451 - 1460
  • [42] Experimental study of the tensile behaviour of GFRP reinforcing bars at elevated temperatures
    Rosa, Ines C.
    Firmo, Joao P.
    Correia, Joao R.
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 324
  • [43] Probabilistic strength prediction for double lap joints composed of pultruded GFRP profiles part I:: Experimental and numerical investigations
    Vallee, Till
    Correia, Joao R.
    Keller, Thomas
    COMPOSITES SCIENCE AND TECHNOLOGY, 2006, 66 (13) : 1903 - 1914
  • [44] Fire resistance behaviour of GFRP-polyurethane composite sandwich panels for building floors
    Proenca, M.
    Garrido, M.
    Correia, J. R.
    Gomes, M. G.
    COMPOSITES PART B-ENGINEERING, 2021, 224
  • [45] Flexural Creep Behaviour of Pultruded GFRP Composites Cross-Arm: A Comparative Study on the Effects of Stacking Sequence
    Alhayek, Abdulrahman
    Syamsir, Agusril
    Supian, Abu Bakar Mohd
    Usman, Fathoni
    Asyraf, Muhammad Rizal Muhammad
    Atiqah, Mohd Afdzaluddin
    POLYMERS, 2022, 14 (07)
  • [46] Cracking and deflections in GFRP RC beams: An experimental study
    Barris, C.
    Torres, L.
    Comas, J.
    Mias, C.
    COMPOSITES PART B-ENGINEERING, 2013, 55 : 580 - 590
  • [47] Experimental study on the fire resistance of RC beams strengthened with near-surface-mounted high-Tg BFRP
    Zhu, Hong
    Wu, Gang
    Zhang, Lei
    Zhang, Jianfeng
    Hui, David
    COMPOSITES PART B-ENGINEERING, 2014, 60 : 680 - 687
  • [48] Experimental study on the fire resistance of all-composite and hybrid web-core sandwich panels for building floors
    Proenca, M.
    Garrido, M.
    Correia, J. R.
    Sena-Cruz, J.
    COMPOSITE STRUCTURES, 2024, 337
  • [49] Experimental study on the concept of liquid cooling for improving fire resistance of FRP structures for construction
    Keller, T
    Zhou, AX
    Tracy, C
    Hugi, E
    Schnewlin, P
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2005, 36 (11) : 1569 - 1580
  • [50] Experimental and analytical investigation of two- and six-plate bonded splice joints on serviceability limit deformations of pultruded GFRP beams
    Turvey, G. J.
    COMPOSITE STRUCTURES, 2014, 111 : 426 - 435