Experimental study on the fire resistance of GFRP pultruded tubular columns

被引:15
作者
Morgado, T. [1 ]
Correia, J. R. [1 ]
Moreira, A. [1 ]
Branco, F. A. [1 ]
Tiago, C. [1 ]
机构
[1] Univ Lisbon, Inst Super Tecn, ICIST, DECivil, P-1049001 Lisbon, Portugal
关键词
Polymer-matrix composites (PMCs); High-temperature properties; Mechanical testing; Pultrusion; PROTECTION SYSTEMS; PROFILES;
D O I
10.1016/j.compositesb.2014.10.005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents experimental investigations about the fire behaviour of GFRP pultruded columns with square tubular cross-section. The objectives of the study were to evaluate (i) the efficacy of passive (calcium silicate (CS) boards) and active (water-cooling) systems in providing fire protection to GFRP pultruded columns; and the effects of (ii) the number of sides exposed to fire; and (iii) the service load level on the GFRP columns' fire response. To this end, fire resistance tests were performed on 1.5 m long GFRP columns, subjected to two different load levels corresponding to axial shortenings of L/1500 and L/750 (L being the span), and simultaneously exposed to fire, in either one or three sides, according to the time-temperature curve defined in ISO 834. Results obtained were analysed regarding the thermal and mechanical responses of the GFRP columns (unprotected and protected), namely in terms of the evolution of axial and transverse displacements, the failure modes and the fire resistance. It was possible to conclude that for one-side exposure, water-cooling is the most effective protection, particularly with flowing water, providing more than 120 min of fire resistance. For three-sides exposure, the fire resistance of the different solutions tested was severely reduced, namely that of the water-cooling systems, which provided fire resistances of only about 20 min, regardless of using flowing water; for this type of exposure, the best performance was provided by the CS board protection, with about 40 min of fire resistance. The results obtained in this study draw the attention to the technical advantages of adopting a building architecture in which the GFRP columns are integrated in the facades and embedded in partition walls, preventing the columns from being exposed to fire in three sides. As expected, the load level increase caused a reduction of fire resistance, due to the higher stresses developed in the sections' walls and to the GFRP strength decrease with temperature. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:201 / 211
页数:11
相关论文
共 50 条
  • [21] Fire performance of pultruded wood-cored GFRP sandwich components for building construction
    Zhang, Lingfeng
    Chen, Kaixi
    Liu, Weiqing
    Liu, Yan
    Wang, Kun
    Ge, Wenjie
    Guo, Kai
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2022, 17
  • [22] A Study on the Design Curves for Pultruded Composite Columns
    Lee, Seungsik
    Chae, Soo-Ha
    Yoon, Soon-Jong
    Cho, Sun-Kyu
    ADVANCED MATERIALS AND PROCESSING, 2007, 26-28 : 337 - +
  • [23] Experimental Investigation of Physical and Mechanical Characteristics of Pultruded/Hand Lay-Up GFRP Thin-Walled Structural Sections and GFRP Pultruded Ribbed Rebars
    Mehra, Ankit Singh
    Singh, Shamsher Bahadur
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024,
  • [24] Experimental and numerical investigation on in-plane compression and shear performance of a pultruded GFRP composite bridge deck
    Xin, Haohui
    Mosallam, Ayman
    Liu, Yuqing
    Xiao, Yi
    He, Jun
    Wang, Congzhe
    Jiang, Zhibo
    COMPOSITE STRUCTURES, 2017, 180 : 914 - 932
  • [25] Experimental characterization of a pultruded GFRP bridge deck for light-weight vehicles
    Lee, Jaehong
    Kim, Youngbin
    Jung, Jinwoo
    Kosmatka, John
    COMPOSITE STRUCTURES, 2007, 80 (01) : 141 - 151
  • [26] Experimental evaluation of thermal effects on the tensile mechanical properties of pultruded GFRP rods
    Crea, F
    Porco, G
    Zinno, R
    APPLIED COMPOSITE MATERIALS, 1997, 4 (03) : 133 - 143
  • [27] Experimental evaluation of thermal effects on the tensile mechanical properties of pultruded GFRP rods
    F. Crea
    G. Porco
    R. Zinno
    Applied Composite Materials, 1997, 4 (3) : 133 - 143
  • [28] Experimental Evaluation of Thermal Effects on the Tensile Mechanical Properties of Pultruded GFRP Rods
    F. Crea
    G. Porco
    R. Zinno
    Applied Composite Materials, 1997, 4 : 133 - 143
  • [29] Axial performance of go-through bolt connection for tubular GFRP columns
    David, K. Linda
    Prebhakumari, KS.
    MATERIALS TODAY-PROCEEDINGS, 2022, 65 : 2034 - 2041
  • [30] A numerical and experimental study of the material properties determining the crushing behaviour of pultruded GFRP profiles under lateral compression
    Regel, Franziska
    van Hattum, Ferrie W. J.
    Dias, Gustavo R.
    JOURNAL OF COMPOSITE MATERIALS, 2013, 47 (14) : 1749 - 1764