Experimental study on the fire resistance of GFRP pultruded tubular columns

被引:15
作者
Morgado, T. [1 ]
Correia, J. R. [1 ]
Moreira, A. [1 ]
Branco, F. A. [1 ]
Tiago, C. [1 ]
机构
[1] Univ Lisbon, Inst Super Tecn, ICIST, DECivil, P-1049001 Lisbon, Portugal
关键词
Polymer-matrix composites (PMCs); High-temperature properties; Mechanical testing; Pultrusion; PROTECTION SYSTEMS; PROFILES;
D O I
10.1016/j.compositesb.2014.10.005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents experimental investigations about the fire behaviour of GFRP pultruded columns with square tubular cross-section. The objectives of the study were to evaluate (i) the efficacy of passive (calcium silicate (CS) boards) and active (water-cooling) systems in providing fire protection to GFRP pultruded columns; and the effects of (ii) the number of sides exposed to fire; and (iii) the service load level on the GFRP columns' fire response. To this end, fire resistance tests were performed on 1.5 m long GFRP columns, subjected to two different load levels corresponding to axial shortenings of L/1500 and L/750 (L being the span), and simultaneously exposed to fire, in either one or three sides, according to the time-temperature curve defined in ISO 834. Results obtained were analysed regarding the thermal and mechanical responses of the GFRP columns (unprotected and protected), namely in terms of the evolution of axial and transverse displacements, the failure modes and the fire resistance. It was possible to conclude that for one-side exposure, water-cooling is the most effective protection, particularly with flowing water, providing more than 120 min of fire resistance. For three-sides exposure, the fire resistance of the different solutions tested was severely reduced, namely that of the water-cooling systems, which provided fire resistances of only about 20 min, regardless of using flowing water; for this type of exposure, the best performance was provided by the CS board protection, with about 40 min of fire resistance. The results obtained in this study draw the attention to the technical advantages of adopting a building architecture in which the GFRP columns are integrated in the facades and embedded in partition walls, preventing the columns from being exposed to fire in three sides. As expected, the load level increase caused a reduction of fire resistance, due to the higher stresses developed in the sections' walls and to the GFRP strength decrease with temperature. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:201 / 211
页数:11
相关论文
共 50 条
  • [1] Experimental study on the fire resistance of GFRP pultruded tubular beams
    Morgado, T.
    Correia, J. R.
    Silvestre, N.
    Branco, F. A.
    COMPOSITES PART B-ENGINEERING, 2018, 139 : 106 - 116
  • [2] Simulation of fire resistance behaviour of pultruded GFRP columns
    Morgado, Tiago
    Silvestre, Nuno
    Correia, Joao R.
    THIN-WALLED STRUCTURES, 2019, 135 : 521 - 536
  • [3] Fire protection systems for building floors made of pultruded GFRP profiles Part 1: Experimental investigations
    Correia, Joao R.
    Branco, Fernando A.
    Ferreira, Joao G.
    Bai, Yu
    Keller, Thomas
    COMPOSITES PART B-ENGINEERING, 2010, 41 (08) : 617 - 629
  • [4] The effects of elevated temperatures on the performance of concrete-filled pultruded GFRP tubular columns
    Tabatabaeian, Mojtaba
    Khaloo, Alireza
    Azizmohammadi, Morteza
    THIN-WALLED STRUCTURES, 2021, 169
  • [5] Experimental and computational investigations on fire resistance of GFRP composite for building facade
    Nguyen, Quynh T.
    Tran, Phuong
    Ngo, Tuan D.
    Tran, Phong A.
    Mendis, Priyan
    COMPOSITES PART B-ENGINEERING, 2014, 62 : 218 - 229
  • [6] Simulation of fire resistance behaviour of pultruded GFRP beams - Part I: Models description and kinematic issues
    Morgado, T.
    Silvestre, N.
    Correia, J. R.
    COMPOSITE STRUCTURES, 2018, 187 : 269 - 280
  • [7] The effect of different passive fire protection systems on the fire reaction properties of GFRP pultruded profiles for civil construction
    Correia, Joao R.
    Branco, Fernando A.
    Ferreira, Joao G.
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2010, 41 (03) : 441 - 452
  • [8] Test on mechanical behavior of pultruded concrete-filled GFRP tubular short columns after elevated temperatures
    Guo, Zhan
    Xia, Lujing
    Lin, Quan
    Chen, Yu
    COMPOSITE STRUCTURES, 2021, 257
  • [9] Effects of Additives on the Mechanical and Fire Resistance Properties of Pultruded Composites
    Romanovskaia, Natalia
    Minchenkov, Kirill
    Gusev, Sergey
    Klimova-Korsmik, Olga
    Safonov, Alexander
    POLYMERS, 2023, 15 (17)
  • [10] A review of the fire behaviour of pultruded GFRP structural profiles for civil engineering applications
    Correia, Joao R.
    Bai, Yu
    Keller, Thomas
    COMPOSITE STRUCTURES, 2015, 127 : 267 - 287