Fit of interim crowns fabricated using photopolymer-jetting 3D printing

被引:110
作者
Mai, Hang-Nga [1 ]
Lee, Kyu-Bok [2 ]
Lee, Du-Hyeong [2 ]
机构
[1] Kyungpook Natl Univ, Dept Prosthodont, Sch Dent, Daegu, South Korea
[2] Kyungpook Natl Univ, Dept Prosthodont, Sch Dent, A3DI, 2175 Dalgubeoldae Ro, Daegu 700705, South Korea
基金
新加坡国家研究基金会;
关键词
POLYMERIZATION; ADAPTATION; ACCURACY;
D O I
10.1016/j.prosdent.2016.10.030
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The fit of interim crowns fabricated using 3-dimensional (3D) printing is unknown. Purpose. The purpose of this in vitro study was to evaluate the fit of interim crowns fabricated using photopolymer-jetting 3D printing and to compare it with that of milling and compression molding methods. Material and methods. Twelve study models were fabricated by making an impression of a metal master model of the mandibular first molar. On each study model, interim crowns (N=36) were fabricated using compression molding (molding group, n=12), milling (milling group, n=12), and 3D polymer-jetting methods. The crowns were prepared as follows: molding group, overimpression technique; milling group, a 5-axis dental milling machine; and polymer-jetting group using a 3D printer. The fit of interim crowns was evaluated in the proximal, marginal, internal axial, and internal occlusal regions by using the image-superimposition and silicone-replica techniques. The Mann-Whitney U test and Kruskal-Wallis tests were used to compare the results among groups (alpha=.05). Results. Compared with the molding group, the milling and polymer-jetting groups showed more accurate results in the proximal and marginal regions (P<.001). In the axial regions, even though the mean discrepancy was smallest in the molding group, the data showed large deviations. In the occlusal region, the polymer-jetting group was the most accurate, and compared with the other groups, the milling group showed larger internal discrepancies (P<.001). Conclusions. Polymer-jet 3D printing significantly enhanced the fit of interim crowns, particularly in the occlusal region.
引用
收藏
页码:208 / 215
页数:8
相关论文
共 26 条
[1]   Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations [J].
Alharbi, Nawal ;
Osman, Reham ;
Wismeijer, Daniel .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (06) :760-767
[2]   THE INFLUENCE OF FINISH LINE CURVATURE ON THE MARGINAL GAP WIDTH OF CERAMIC COPINGS [J].
Asavapanumas, Chutima ;
Leevailoj, Chalermpol .
JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (04) :227-233
[3]   3-D printing: The new industrial revolution [J].
Berman, Barry .
BUSINESS HORIZONS, 2012, 55 (02) :155-162
[4]   A review of selected dental literature on contemporary provisional fixed prosthodontic treatment: Report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics [J].
Burns, DR ;
Beck, DA ;
Nelson, SK .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (05) :474-497
[5]   Direct Inkjet Printing of dental Prostheses Made of Zirconia [J].
Ebert, J. ;
Oezkol, E. ;
Zeichner, A. ;
Uibel, K. ;
Weiss, Oe. ;
Koops, U. ;
Telle, R. ;
Fischer, H. .
JOURNAL OF DENTAL RESEARCH, 2009, 88 (07) :673-676
[6]   IMPROVING THE FIT OF CROWNS WITH DIE SPACERS [J].
GRAJOWER, R ;
ZUBERI, Y ;
LEWINSTEIN, I .
JOURNAL OF PROSTHETIC DENTISTRY, 1989, 61 (05) :555-563
[7]  
Gratton D.G. Aquilino., 2004, Dental Clinics of North America, V48, P487, DOI DOI 10.1016/J.CDEN.2003.12.007
[8]   CONSIDERATIONS IN MEASUREMENT OF MARGINAL FIT [J].
HOLMES, JR ;
BAYNE, SC ;
HOLLAND, GA ;
SULIK, WD .
JOURNAL OF PROSTHETIC DENTISTRY, 1989, 62 (04) :405-408
[9]   Complete-mouth rehabilitation using a 3D printing technique and the CAD/CAM double scanning method: A clinical report [J].
Joo, Han-Sung ;
Park, Sang-Won ;
Yun, Kwi-Dug ;
Lim, Hyun-Pil .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (01) :3-7
[10]   In vitro evaluation of the marginal integrity of CAD/CAM interim crowns [J].
Khng, Kwang Yong Kelvin ;
Ettinger, Ronald L. ;
Armstrong, Steven R. ;
Lindquist, Terry ;
Gratton, David G. ;
Qian, Fang .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (05) :617-623