The spatial QRS-T angle in the Frank vectorcardiogram: accuracy of estimates derived from the 12-lead electrocardiogram

被引:47
作者
Schreurs, Charlotte A. [1 ]
Algra, Annemijn M. [1 ]
Man, Sum-Che [1 ]
Cannegieter, Suzanne C. [2 ]
van der Wall, Ernst E. [1 ]
Schalij, Martin J. [1 ]
Kors, Jan A. [3 ]
Swenne, Cees A. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Clin Epidemiol, NL-2300 RC Leiden, Netherlands
[3] Erasmus MC, Dept Med Informat, Rotterdam, Netherlands
关键词
PREDICTS CARDIAC DEATH; CORONARY-HEART-DISEASE; VENTRICULAR REPOLARIZATION; ORTHOGONAL ELECTROCARDIOGRAM; PROGNOSTIC-SIGNIFICANCE; ANALYSIS SYSTEM; NORMAL MEN; POPULATION; MORTALITY; LEADS;
D O I
10.1016/j.jelectrocard.2010.03.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Purpose: The spatial QRS-T angle (SA), a predictor of sudden cardiac death, is a vectorcardiographic variable. Gold standard vertorcardiograms (VCGs) are recorded by using the Frank electrode positions. However, with the commonly available 12-lead ECG, VCGs must be synthesized by matrix multiplication (inverse Dower matrix/Kors matrix). Alternatively, Rautaharju proposed a method to calculate SA directly from the 12-lead ECG. Neither spatial angles computed by using the inverse Dower matrix (SA-D) nor by using the Kors matrix (SA-K) or by using Rautaharju's method (SA-R) have been validated with regard to the spatial angles as directly measured in the Frank VCG (SA-F). Our present study aimed to perform this essential validation. Methods: We analyzed SAs in 1220 simultaneously recorded 12-lead ECGs and VCGs, in all data, in SA-F-based tertiles, and after stratification according to pathology or sex. Results: Linear regression of SA-K, SA-D, and SA-R on SA-F yielded offsets of 0.01 degrees, 20.3 degrees, and 28.3 degrees and slopes of 0.96, 0.86, and 0.79, respectively. The bias of SA-K with respect to SA-F (mean +/- SD, -3.2 degrees +/- 13.9 degrees) was significantly (P < .001) smaller than the bias of both SA-D and SA-R with respect to SA-F (8.0 degrees +/- 18.6 degrees and 9.8 degrees +/- 24.6 degrees, respectively); tertile analysis showed a much more homogeneous behavior of the bias in SA-K than of both the bias in SA-D and in SA-R. In pathologic ECGs, there was no significant bias in SA-K; bias in men and women did not differ. Conclusion: SA-K resembled SA-F best. In general, when there is no specific reason either to synthesize VCGs with the inverse Dower matrix or to calculate the spatial QRS-T angle with Rautaharju's method, it seems prudent to use the Kors matrix. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:294 / 301
页数:8
相关论文
共 28 条
[1]   Predicting Ventricular Arrhythmias in Patients With Ischemic Heart Disease Clinical Application of the ECG-Derived QRS-T Angle [J].
Borleffs, C. Jan Willem ;
Scherptong, Roderick W. C. ;
Man, Sum-Che ;
van Welsenes, Guido H. ;
Bax, Jeroen J. ;
van Erven, Lieselot ;
Swenne, Cees A. ;
Schalij, Martin J. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (05) :548-554
[2]   The electrical T-axis and the spatial QRS-T angle are independent predictors of long-term mortality in patients admitted with acute ischemic chest pain [J].
de Torbal, A ;
Kors, JA ;
van Herpen, G ;
Meij, S ;
Nelwan, S ;
Simoons, ML ;
Boersma, E .
CARDIOLOGY, 2004, 101 (04) :199-207
[3]   Determinants of electrocardiographic and spatial vectorcardiographic descriptors of ventricular repolarization in normal subjects [J].
Dilaveris, P ;
Pantazis, A ;
Gialafos, E ;
Triposkiadis, F ;
Gialafos, J .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (08) :912-+
[4]   The effects of cigarette smoking on the heterogeneity of ventricular repolarization [J].
Dilaveris, P ;
Pantazis, A ;
Gialafos, E ;
Triposkiadis, F ;
Gialafos, J .
AMERICAN HEART JOURNAL, 2001, 142 (05) :833-837
[5]   The spatial QRS-T angle as a marker of ventricular repolarisation in hypertension [J].
Dilaveris, P ;
Gialafos, E ;
Pantazis, A ;
Synetos, A ;
Triposkiadis, F ;
Gialafos, J .
JOURNAL OF HUMAN HYPERTENSION, 2001, 15 (01) :63-70
[6]  
DOWER G E, 1980, Clinical Cardiology, V3, P87
[7]  
Draisma HHM, 2005, COMPUT CARDIOL, V32, P515
[8]   CORRECTED ORTHOGONAL ELECTROCARDIOGRAM + VECTORCARDIOGRAM IN 510 NORMAL MEN ( FRANK LEAD SYSTEM ) [J].
DRAPER, HW ;
LITTMANN, D ;
PEFFER, CJ ;
STALLMANN, FW ;
PIPBERGER, HV .
CIRCULATION, 1964, 30 (06) :853-&
[9]   VECTORCARDIOGRAM SYNTHESIZED FROM A 12-LEAD ECG - SUPERIORITY OF THE INVERSE DOWER MATRIX [J].
EDENBRANDT, L ;
PAHLM, O .
JOURNAL OF ELECTROCARDIOLOGY, 1988, 21 (04) :361-367
[10]   Improved EASI coefficients:: Their derivation, values, and performance [J].
Feild, DQ ;
Feldman, CL ;
Horácek, BM .
JOURNAL OF ELECTROCARDIOLOGY, 2002, 35 :23-33