Radioguided occult lesion localization (ROLL) for non-palpable breast cancer: A comparison between day-before and same-day protocols

被引:19
|
作者
Aydogan, Fatih
Ozben, Volkan [1 ]
Celik, Varol
Uras, Cihan
Tahan, Guelguen [2 ]
Gazioglu, Ertugrul
Cengiz, Ali
Ferahman, Mehmet
Cercel, Ali
Yilmaz, Mehmet Halit [3 ]
Halac, Metin [4 ]
Unal, Hilal
机构
[1] Istanbul Univ, Cerrahpasa Med Sch, Dept Gen Surg, Cerrahpasa Tip Fak, TR-34098 Istanbul, Turkey
[2] Marmara Univ, Inst Gastroenterol, Istanbul, Turkey
[3] Istanbul Univ, Cerrahpasa Med Sch, Dept Radiol, TR-34098 Istanbul, Turkey
[4] Istanbul Univ, Cerrahpasa Med Sch, Dept Nucl Med, TR-34098 Istanbul, Turkey
关键词
ROLL; Non-palpable breast cancer; Same-day injection; Day-before injection; WIRE-GUIDED LUMPECTOMY; SENTINEL NODE; 2-DAY PROTOCOLS; BIOPSY; EXCISION; LYMPHOSCINTIGRAPHY; RADIOISOTOPE; EXPERIENCE; INJECTION; 1-DAY;
D O I
10.1016/j.breast.2010.01.017
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Although radioguided occult lesion localization (ROLL) has become a widely accepted technique, the optimal time interval between the radioisotope injection and surgery has not yet been determined. Aim: To delineate the effects of time from the injection of the radionuclide until surgery on the ROLL success rate in a patient population diagnosed as having non-palpable breast cancer. Methods: Between December 2004 and May 2009,75 patients underwent ROLL procedure. The day-before protocol and same-day protocols included 50 and 25 breast cancer patients respectively. Results: The two study groups were comparable in terms of age, localization technique, radiological findings and the type of surgical procedures (P > 0.05). No statistically significant difference was noticed in the pathological diagnosis, cancer size and the surgical margin clearance between the two groups (P > 0.05). Conclusions: Same-day injection of the radiotracer was not superior to the day-before injection in ROLL The day-before protocol can be scheduled for the convenience of both patients and hospital staff. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:226 / 230
页数:5
相关论文
共 28 条
  • [21] Use of wire-guided and radio-guided occult lesion localization for non-palpable breast lesions: A systematic literature review and meta-analysis of current evidence
    Kiruparan, Nanthesh
    Kiruparan, Pasupathy
    Debnath, Debasish
    ASIAN JOURNAL OF SURGERY, 2022, 45 (01) : 79 - 88
  • [22] Comparison between one day and two days protocols for sentinel node mapping of breast cancer patients
    Ali, Jangijoo
    Alireza, Rezapanah
    Mostafa, Mehrabibahar
    Naser, Forghani Mohammad
    Bahram, Memar
    Ramin, Sadeghi
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2011, 14 (03): : 313 - 315
  • [23] Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control
    Arantes Pereira, Fernanda Philadelpho
    Martins, Gabriela
    Gregorio Calas, Maria Julia
    Fonseca Torres de Oliveira, Maria Veronica
    Gasparetto, Emerson Leandro
    Barbosa da Fonseca, Lea Mirian
    BMC MEDICAL IMAGING, 2013, 13
  • [24] Radioguided occult lesion localization plus sentinel node biopsy (SNOLL) versus wire-guided localization plus sentinel node detection: A case control study of 129 unifocal pure invasive non-palpable breast cancers
    Giacalone, P. L.
    Bourdon, A.
    Trinh, P. D.
    Taourel, P.
    Rathat, G.
    Sainmont, M.
    Perocchia, H.
    Rossi, M.
    Rouleau, C.
    EJSO, 2012, 38 (03): : 222 - 229
  • [25] Efficacy of localization of non-palpable, invasive breast cancer: Wire localization vs. Iodine-125 seed: A historical comparison
    in't Hout, B. A.
    Schenk, K. E.
    van der Linden, A. N.
    Roumen, R. M. H.
    BREAST, 2016, 29 : 8 - 13
  • [26] Non-Palpable Breast Cancer: A Targeting Challenge-Comparison of Radio-Guided vs. Wire-Guided Localization Techniques
    Drozgyik, Andras
    Kollar, Daniel
    Dankhazi, Levente
    Harmati, Istvan a.
    Szalay, Krisztina
    Molnar, Tamas F.
    BIOMEDICINES, 2024, 12 (11)
  • [27] Survey of the Radioguided Surgery Working Group (GTCRG-RGSWG) of the Spanish Society of Nuclear Medicine and Molecular Imaging (SEMNIM): Radioguided localization of non-palpable breast lesions with or without indication for selective sentinel node biopsy: ROLL, SNOLL and 125I seeds
    Perez, P. A. de la Riva
    Salazar, D. Carrera
    Barranco, P. Paredes
    Girones, E. Goni
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2022, 41 (04): : 223 - 230
  • [28] Cost-Effectiveness of Radioguided Occult Lesion Localization (ROLL) Versus Wire-Guided Localization (WGL) in Breast Conserving Surgery for Nonpalpable Breast Cancer: Results from a Randomized Controlled Multicenter Trial
    Postma, E. L.
    Koffijberg, H.
    Verkooijen, H. M.
    Witkamp, A. J.
    van den Bosch, M. A. A. J.
    van Hillegersberg, R.
    ANNALS OF SURGICAL ONCOLOGY, 2013, 20 (07) : 2219 - 2226