Two media method for gamma ray attenuation coefficient measurement of archaeological ceramic samples

被引:0
作者
Silva, RMCE [1 ]
Appoloni, CR [1 ]
Parreira, PS [1 ]
Espinoza-Quiñones, FR [1 ]
Coimbra, MM [1 ]
Aragao, PHA [1 ]
机构
[1] Univ Estadual Londrina, Dept Phys, BR-86051970 Londrina, PR, Brazil
关键词
D O I
暂无
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
This work reports the application of an alternative methodology for the linear attenuation coefficient determination of irregular shape samples, in such a way that it is not necessary to know the sample thickness. Based on this method, indigenous archaeological ceramic fragments from the region of Londrina, north of Parana State in Brazil, were studied. On the other hand, theoretical mass attenuation coefficient values were determined with the XCOM computer code. With the results obtained, it was concluded that the two media method works very well for the linear attenuation coefficient measurement of irregular-shaped ceramic samples, which makes it suitable, especially, for archaeometric studies. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1011 / 1016
页数:6
相关论文
共 50 条
  • [31] Mass attenuation coefficient of olive peat material for absorbing gamma ray energy
    Mohammad W.Marashdeh
    Hanan Saleh
    NuclearScienceandTechniques, 2019, 30 (07) : 71 - 79
  • [32] Two-phase flow component fraction measurement using gamma-ray attenuation technique
    Mohsen Sharifzadeh
    Hosein Khalafi
    Hosein Afarideh
    Ehsanallah Noori
    Nuclear Science and Techniques, 2017, 28 (06) : 27 - 33
  • [33] Two-phase flow component fraction measurement using gamma-ray attenuation technique
    Sharifzadeh, Mohsen
    Khalafi, Hosein
    Afarideh, Hosein
    Noori, Ehsanallah
    NUCLEAR SCIENCE AND TECHNIQUES, 2017, 28 (06)
  • [34] Two-phase flow component fraction measurement using gamma-ray attenuation technique
    Mohsen Sharifzadeh
    Hosein Khalafi
    Hosein Afarideh
    Ehsanallah Noori
    Nuclear Science and Techniques, 2017, 28
  • [35] Correction by self-attenuation in gamma-ray spectrometry for environmental samples
    Quindos, L. S.
    Sainz, C.
    Fuente, I.
    Nicolas, J.
    Quindos, L.
    Arteche, J.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2006, 270 (02) : 339 - 343
  • [36] Correction by self-attenuation in gamma-ray spectrometry for environmental samples
    L. S. Quindós
    C. Sainz
    I. Fuente
    J. Nicolás
    L. Quindós
    J. Arteche
    Journal of Radioanalytical and Nuclear Chemistry, 2006, 270 : 339 - 343
  • [37] Corrections for self-attenuation in gamma-ray spectrometry of bulk samples
    Boshkova, T
    Minev, L
    APPLIED RADIATION AND ISOTOPES, 2001, 54 (05) : 777 - 783
  • [38] Bifocal technique for accurate measurement of total attenuation coefficient in scattering media with OCT
    Kholodnykh, AI
    Petrova, IY
    Motamedi, M
    Esenaliev, RO
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 2251 - 2252
  • [39] CALCULATING EFFECTIVE ATTENUATION COEFFICIENT OF GAMMA-RADIATION IN MICRO-NONHOMOGENEOUS-MEDIA
    SHMONIN, LI
    POTREBEN.GK
    ATOMNAYA ENERGIYA, 1973, 34 (04): : 284 - 284
  • [40] X-ray attenuation coefficient measurement of argentine near absorption edges
    Yi, R. (yrq@sina.com), 1600, Editorial Office of High Power Laser and Particle Beams (26):