Two media method for gamma ray attenuation coefficient measurement of archaeological ceramic samples

被引:0
|
作者
Silva, RMCE [1 ]
Appoloni, CR [1 ]
Parreira, PS [1 ]
Espinoza-Quiñones, FR [1 ]
Coimbra, MM [1 ]
Aragao, PHA [1 ]
机构
[1] Univ Estadual Londrina, Dept Phys, BR-86051970 Londrina, PR, Brazil
关键词
D O I
暂无
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
This work reports the application of an alternative methodology for the linear attenuation coefficient determination of irregular shape samples, in such a way that it is not necessary to know the sample thickness. Based on this method, indigenous archaeological ceramic fragments from the region of Londrina, north of Parana State in Brazil, were studied. On the other hand, theoretical mass attenuation coefficient values were determined with the XCOM computer code. With the results obtained, it was concluded that the two media method works very well for the linear attenuation coefficient measurement of irregular-shaped ceramic samples, which makes it suitable, especially, for archaeometric studies. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1011 / 1016
页数:6
相关论文
共 50 条
  • [21] Measurement of average mass attenuation coefficient of air for 137Cs gamma-ray irradiation beam
    Yi, Chul-Young
    Kim, Yoon Ho
    Kim, In Jung
    Park, Jong In
    Seong, Young Min
    METROLOGIA, 2024, 61 (06)
  • [22] Effect of ilmenite on the attenuation coefficient of gamma ray shielding cementious matrix
    El-Faramawy, Nabil
    Ramadan, Wageeh
    El-Zakla, Tarek
    Sayed, Magda
    El-Dessouky, Mohamed
    Sakr, Khaled
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2015, 170 (11): : 876 - 886
  • [23] The attenuation coefficient of barite concrete subjected to gamma-ray radiation
    Budi, Gogot Setyo
    Koentjoro, Hurijanto
    Wijaya, Joshua
    Sikomena, Evan Filbert
    INTERNATIONAL CONFERENCE ON SUSTAINABLE CIVIL ENGINEERING STRUCTURES AND CONSTRUCTION MATERIALS (SCESCM 2018), 2019, 258
  • [24] A simple numerical method for gamma-ray self-attenuation correction for samples of common geometries
    Agarwal, Chhavi
    Poi, Sanhita
    Goswami, A.
    Gathibandhe, Manohar
    Agrawal, R. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 597 (2-3): : 198 - 202
  • [25] A METHOD OF LOW ENERGY GAMMA-RAY SPECTROMETRY APPLICABLE TO MEASUREMENT OF BIOLOGICAL SAMPLES
    PARKER, RP
    PHYSICS IN MEDICINE AND BIOLOGY, 1962, 7 (03): : 301 - &
  • [26] POROSITY MEASUREMENTS OF CORE SAMPLES USING GAMMA-RAY ATTENUATION
    BODWADKAR, SV
    REIS, JC
    NUCLEAR GEOPHYSICS, 1994, 8 (01): : 61 - 78
  • [27] GAMMA-RAY SELF-ATTENUATION CORRECTIONS IN ENVIRONMENTAL SAMPLES
    Robu, E.
    Giovani, C.
    ROMANIAN REPORTS IN PHYSICS, 2009, 61 (02) : 295 - 300
  • [28] Porosity measurements of core samples using gamma-ray attenuation
    Bodwadkar, S.V.
    Reis, J.C.
    Nuclear Geophysics, 1994, 8 (01): : 61 - 78
  • [29] Mass attenuation coefficient of olive peat material for absorbing gamma ray energy
    Marashdeh, Mohammad W.
    Saleh, Hanan
    NUCLEAR SCIENCE AND TECHNIQUES, 2019, 30 (07)
  • [30] Mass attenuation coefficient of olive peat material for absorbing gamma ray energy
    Mohammad W.Marashdeh