Benchtop NIR method development for continuous manufacturing scale to enable efficient PAT application for solid oral dosage form

被引:21
作者
Alam, Md Anik [1 ]
Liu, Yang Angela [1 ]
Dolph, Stephanie [1 ]
Pawliczek, Marcin [2 ]
Peeters, Elisabeth [1 ]
Palm, Andrew [1 ]
机构
[1] Pfizer Inc, Worldwide Res & Dev, Groton, CT 06340 USA
[2] Pfizer Mfg Deutschland GmbH, Pfizer Global Supply, Freiburg, Germany
关键词
Process Analytical Technology; Near infrared; Continuous manufacturing; Direct compression; Potency monitoring; Calibration; Robustness; PROCESS ANALYTICAL TECHNOLOGY; NEAR-INFRARED SPECTROSCOPY; FEED FRAME; BLEND POTENCY; DRUG CONTENT;
D O I
10.1016/j.ijpharm.2021.120581
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A Near Infrared (NIR) method was developed using a small benchtop feed frame system to quantify Saccharin potency in a powder blend during continuous manufacturing process. A 15-point Design of Experiments (DoE) was created based on the NIR spectral response and compositions of the formulation to develop a calibration set. The calibration set was designed to create compositional and raw material lots variation using minimum resources. The calibration experiments utilized around 0.5 kg Saccharin (Active Pharmaceutical Ingredient (API) surrogate) and 1.8 kg of excipients. Partial Least Square (PLS) modeling was used to develop a quantitative NIR method from the calibration data. The NIR method was implemented during 5 test batches in two different manufacturing sites across different potency levels at a continuous manufacturing platform for direction compression. Acceptable prediction performance was achieved from the NIR method at both sites. The NIR method was robust against changes in process scale and NIR instruments. The variance information built into the calibration set was found to be critical to successful model performance. This study shows a benchtop feed frame can be used for material sparing calibration method development without operating at a full-scale process line and applied across multiple sites, instruments at different potency levels.
引用
收藏
页数:9
相关论文
共 17 条
[1]   Designing a calibration set in spectral space for efficient development of an NIR method for tablet analysis [J].
Alam, Md Anik ;
Drennen, James, III ;
Anderson, Carl .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 145 :230-239
[2]  
Blackwood D.O., 2019, MODEL, P547, DOI [10.1002/9781119600800.ch72, DOI 10.1002/9781119600800.CH72]
[3]   Inline Real-Time Near-Infrared Granule Moisture Measurements of a Continuous Granulation-Drying-Milling Process [J].
Chablani, Lipika ;
Taylor, Michael K. ;
Mehrotra, Amit ;
Rameas, Patrick ;
Stagner, William C. .
AAPS PHARMSCITECH, 2011, 12 (04) :1050-1055
[4]  
Colon Y., 2018, INT J PHARM
[5]   Near Infrared Method Development for a Continuous Manufacturing Blending Process [J].
Colon, Yleana M. ;
Florian, Miguel A. ;
Acevedo, David ;
Mendez, Rafael ;
Romanach, Rodolfo J. .
JOURNAL OF PHARMACEUTICAL INNOVATION, 2014, 9 (04) :291-301
[6]   Near infrared and Raman spectroscopy for the in-process monitoring of pharmaceutical production processes [J].
De Beer, T. ;
Burggraeve, A. ;
Fonteyne, M. ;
Saerens, L. ;
Remon, J. P. ;
Vervaet, C. .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2011, 417 (1-2) :32-47
[7]   Development and validation of an in-line NIR spectroscopic method for continuous blend potency determination in the feed frame of a tablet press [J].
De Leersnyder, Fien ;
Peeters, Elisabeth ;
Djalabi, Hasna ;
Vanhoorne, Valerie ;
Van Snick, Bernd ;
Hong, Ke ;
Hammond, Stephen ;
Liu, Angela Yang ;
Ziemons, Eric ;
Vervaet, Chris ;
De Beer, Thomas .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 151 :274-283
[8]   Process Analytical Technology for continuous manufacturing of solid-dosage forms [J].
Fonteyne, Margot ;
Vercruysse, Jurgen ;
De Leersnyder, Fien ;
Van Snick, Bernd ;
Vervaet, Chris ;
Remon, Jean Paul ;
De Beer, Thomas .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2015, 67 :159-166
[9]  
Food and Drug Administration U, 2019, QUAL CONS CONT MAN G
[10]   Sample Mass Estimate for the Use of Near-Infrared and Raman Spectroscopy to Monitor Content Uniformity in a Tablet Press Feed Frame of a Drug Product Continuous Manufacturing Process [J].
Hetrick, Evan M. ;
Shi, Zhenqi ;
Harms, Zachary D. ;
Myers, David P. .
APPLIED SPECTROSCOPY, 2021, 75 (02) :216-224