ORGANIC SCINTILLATOR FOR REAL-TIME NEUTRON DOSIMETRY

被引:9
作者
Beyer, Kyle A. [1 ]
Di Fulvio, Angela [1 ]
Stolarczyk, Liliana [2 ]
Parol, Wiktor [2 ]
Mojzeszek, Natalia [2 ]
Kopec, Renata [2 ]
Clarke, Shaun D. [1 ]
Pozzi, Sara A. [1 ]
机构
[1] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
[2] Polish Acad Sci, Inst Nucl Phys, Radzikowskiego 152, PL-31342 Krakow, Poland
关键词
D O I
10.1093/rpd/ncx255
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We developed a radiation detector based on an organic scintillator for spectrometry and dosimetry of out-of-field secondary neutrons from clinical proton beams. The detector consists of an EJ-299-34 crystalline organic scintillator, coupled by fiber optic cable to a silicon photomultiplier (SiPM). Proof of concept measurements were taken with Cs-137 and Cf-252, and corresponding simulations were performed in MCNPX-PoliMi. Despite its small size, the detector is able to discriminate between neutron and gamma-rays via pulse shape discrimination. We simulated the response function of the detector to monoenergetic neutrons in the 100 keV-0 MeV range using MCNPX-PoliMi. The measured unfolded 252Cf neutron spectrum is in good agreement with the theoretical Watt fission spectrum. We determined the ambient dose equivalent by folding the spectrum with the fluence-to-ambient dose conversion coefficient, with a 1.4% deviation from theory. Some preliminary proton beam experiments were preformed at the Bronowice Cyclotron Center patient treatment facility using a clinically relevant proton pencil beam for brain tumor and craino-spinal treatment directed at a child phantom.
引用
收藏
页码:355 / 359
页数:5
相关论文
共 9 条
[1]  
Birks J. B., 2013, INT SERIES MONOGRAPH, V27
[2]  
Bourne M. M., 2016, THESIS
[3]   A SCINTILLATION COUNTER WITH NEUTRON AND GAMMA-RAY DISCRIMINATORS [J].
BROOKS, FD .
NUCLEAR INSTRUMENTS & METHODS, 1959, 4 (03) :151-163
[4]  
International Commission on Radiological Protection, 1997, ICRP PUBL, V23
[5]  
Miller E. C., 2012, MPPOST MANUAL
[6]   Application of Al2O3:C+fibre dosimeters for 290 MeV/n carbon therapeutic beam dosimetry [J].
Nascimento, L. F. ;
Vanhavere, F. ;
Kodaira, S. ;
Kitamura, H. ;
Verellen, D. ;
De Deene, Y. .
RADIATION PHYSICS AND CHEMISTRY, 2015, 115 :75-80
[7]   Assessing the risk of second malignancies after modern radiotherapy [J].
Newhauser, Wayne D. ;
Durante, Marco .
NATURE REVIEWS CANCER, 2011, 11 (06) :438-448
[8]   Pulse shape discrimination in the plastic scintillator EJ-299-33 [J].
Pozzi, S. A. ;
Bourne, M. M. ;
Clarke, S. D. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 723 :19-23
[9]   Maxed, a computer code for maximum entropy deconvolution of multisphere neutron spectrometer data [J].
Reginatto, M ;
Goldhagen, P .
HEALTH PHYSICS, 1999, 77 (05) :579-583