Superheated emulsions as high-energy neutron dosemeters

被引:7
作者
Das, M
Sawamura, T
Abe, M
Kaneko, JH
Homma, A
Fujita, F
Tsuda, S
Nishitani, T
机构
[1] Hokkaido Univ, Grad Sch Engn, Dept Quantum Energy Engn, Kita Ku, Sapporo, Hokkaido 0608628, Japan
[2] Japan Atom Energy Res Inst, Tokai, Ibaraki 3191195, Japan
基金
日本学术振兴会;
关键词
D O I
10.1093/rpd/nch115
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Superheated emulsions being inexpensive, easy to fabricate, and having tissue equivalent composition make them as one of the popular neutron dosemeters. One more advantage is that they can be made insensitive to gamma rays by the choice of the sensitive liquid. It is observed that the response of commercially available bubble detector to neutron decreases above 20 MeV while its response is roughly flat in the 0.1-15 MeV region. This restricts its application as a dosemeter to high-energy neutrons. The response of bubble detector from Bubble Technology Industries, has been observed by using Pb-breeder for high-energy neutrons from different facilities in Japan. It is observed that 2-3 cm Pb-breeder is effective in increasing the response of the detector to the nominal value. Theoretical calculation using MCNPX code indicates an increase in neutrons in the energy range of 0.1-10 MeV with Pb-breeder. The present work indicates the possibility of using the bubble detector as a dosemeter to high-energy neutron using a Pb-breeder of proper thickness.
引用
收藏
页码:325 / 331
页数:7
相关论文
共 15 条
[1]   Improved response of bubble detectors to high energy neutrons [J].
Agosteo, S ;
Silari, M ;
Ulrici, L .
RADIATION PROTECTION DOSIMETRY, 2000, 88 (02) :149-155
[2]  
Alberts WG, 2001, RADIAT PROT DOSIM, V96, P251, DOI 10.1093/oxfordjournals.rpd.a006594
[3]   Characterization of a 40-90 MeV 7Li(p,n) neutron source at TIARA using a proton recoil telescope and a TOF method [J].
Baba, M ;
Nauchi, Y ;
Iwasaki, T ;
Kiyosumi, T ;
Yoshioka, M ;
Matsuyama, S ;
Hirakawa, N ;
Nakamura, T ;
Tanaka, S ;
Meigo, S ;
Nakashima, H ;
Tanaka, S ;
Nakao, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (2-3) :454-465
[4]  
BAILEY S, 2000, NUCL NEWS, P32
[5]   Electronic neutron personal dosimetry with superheated drop detectors [J].
d'Errico, F ;
Apfel, RE ;
Curzio, G ;
Nath, R .
RADIATION PROTECTION DOSIMETRY, 2001, 96 (1-3) :261-264
[6]   Application of superheated emulsion in neutron spectrometry at 45 MeV electron linac [J].
Das, M ;
Sawamura, T ;
Kitaichi, M ;
Sawamura, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 517 (1-3) :34-41
[7]   SUPERHEATED-DROP (BUBBLE) NEUTRON DETECTORS AND THEIR COMPLIANCE WITH ICRP-60 [J].
DERRICO, F ;
ALBERTS, WG .
RADIATION PROTECTION DOSIMETRY, 1994, 54 (3-4) :357-360
[8]   Neutron ambient dosimetry with superheated drop (bubble) detectors [J].
dErrico, F ;
Alberts, WG ;
Dietz, E ;
Gualdrini, G ;
Kurkdjian, J ;
Noccioni, P ;
Siebert, BRL .
RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) :397-400
[9]  
ICRP, 1996, ANN ICRP, V74
[10]   Bubble detectors - A maturing technology [J].
Ing, H ;
Noulty, RA ;
McLean, TD .
RADIATION MEASUREMENTS, 1997, 27 (01) :1-11