Towards automated extraction of 2D standard fetal head planes from 3D ultrasound acquisitions: A clinical evaluation and quality assessment comparison

被引:8
作者
Skelton, E. [1 ,2 ]
Matthew, J. [1 ,2 ]
Li, Y. [3 ]
Khanal, B. [2 ]
Martinez, J. J. Cerrolaza [3 ]
Toussaint, N. [2 ]
Gupta, C. [1 ]
Knight, C. [1 ,4 ]
Kainz, B. [2 ,3 ]
Hajnal, J. V. [1 ,2 ]
Rutherford, M. [1 ,4 ]
机构
[1] Kings Coll London, Perinatal Imaging Dept, London, England
[2] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
[3] Imperial Coll London, Dept Comp, London, England
[4] Guys & St Thomas NHS Fdn Trust, London, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
Clinical evaluation; Fetal imaging; Quality assessment; Ultrasound; SONOGRAPHY; BRAIN; RELIABILITY; IMAGES; AUDIT;
D O I
10.1016/j.radi.2020.11.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Clinical evaluation of deep learning (DL) tools is essential to compliment technical accuracy metrics. This study assessed the image quality of standard fetal head planes automatically-extracted from three-dimensional (3D) ultrasound fetal head volumes using a customised DL-algorithm. Methods: Two observers retrospectively reviewed standard fetal head planes against pre-defined image quality criteria. Forty-eight images (29 transventricular, 19 transcerebellar) were selected from 91 transabdominal fetal scans (mean gestational age = 26 completed weeks, range = 20(+5)-32(+3) weeks). Each had two-dimensional (2D) manually-acquired (2D-MA), 3D operator-selected (3D-OS) and 3D-DL automatically-acquired (3D-DL) images. The proportion of adequate images from each plane and mo-dality, and the number of inadequate images per plane was compared for each method. Inter and intra-observer agreement of overall image quality was calculated. Results: Sixty-seven percent of 3D-OS and 3D-DL transventricular planes were adequate quality. Forty-five percent of 3D-OS and 55% of 3D-DL transcerebellar planes were adequate. Seventy-one percent of 3D-OS and 86% of 3D-DL transventricular planes failed with poor visualisation of intra-cranial structures. Eighty-six percent of 3D-OS and 80% of 3D-DL transcerebellar planes failed due to inadequate visualisation of cerebellar hemispheres. Image quality was significantly different between 2D and 3D, however, no significant difference between 3D-modalities was demonstrated (p < 0.005). Inter-observer agreement of transventricular plane adequacy was moderate for both 3D-modalities, and weak for transcerebellar planes. Conclusion: The 3D-DL algorithm can automatically extract standard fetal head planes from 3D-head volumes of comparable quality to operator-selected planes. Image quality in 3D is inferior to corre-sponding 2D planes, likely due to limitations with 3D-technology and acquisition technique. Implications for practice: Automated image extraction of standard planes from US-volumes could facil-itate use of 3DUS in clinical practice, however image quality is dependent on the volume acquisition technique. (c) 2020 The College of Radiographers. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:519 / 526
页数:8
相关论文
共 33 条
  • [11] Online evaluation of fetal second-trimester four-chamber view images: a comparison of six evaluation methods
    Jaudi, S.
    Du Montcel, S. Tezenas
    Fries, N.
    Nizard, J.
    Desfontaines, V. Halley
    Dommergues, M.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2011, 38 (02) : 185 - 190
  • [12] Key challenges for delivering clinical impact with artificial intelligence
    Kelly, Christopher J.
    Karthikesalingam, Alan
    Suleyman, Mustafa
    Corrado, Greg
    King, Dominic
    [J]. BMC MEDICINE, 2019, 17 (01)
  • [13] Li Y, LECT NOTES COMPUTER
  • [14] Three-dimensional visualisation of the fetal heart using prenatal MRI with motion-corrected slice-volume registration: a prospective, single-centre cohort study
    Lloyd, David F. A.
    Pushparajah, Kuberan
    Simpson, John M.
    van Amerom, Joshua F. P.
    van Poppel, Milou P. M.
    Schulz, Alexander
    Kainz, Bernard
    Deprez, Maria
    Lohezic, Maelene
    Allsop, Joanna
    Mathur, Sujeev
    Bellsham-Revell, Hannah
    Vigneswaran, Trisha
    Charakida, Marietta
    Miller, Owen
    Zidere, Vita
    Sharland, Gurleen
    Rutherford, Mary
    Hajnal, Joseph V.
    Razavi, Reza
    [J]. LANCET, 2019, 393 (10181) : 1619 - 1627
  • [15] N Litigation in Obstetrical Sonography: Lessons Learned From 100 Consecutive Cases in the Public Library of Law
    Malik, Yusria
    Jackson, David
    [J]. OBSTETRICS AND GYNECOLOGY, 2017, 129 : 165S - 165S
  • [16] Sonographic examination of the fetal central nervous system: guidelines for performing the 'basic examination' and the 'fetal neurosonogram'
    Malinger, Gustavo
    Monteagudo, Ana
    Pilu, Gianluigi
    Timor-Tritsch, Ilan
    Toi, Ants
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 29 (01) : 109 - 116
  • [17] Interrater reliability: the kappa statistic
    McHugh, Mary L.
    [J]. BIOCHEMIA MEDICA, 2012, 22 (03) : 276 - 282
  • [18] Mu~noz H, ULTRASOUND OBSTET GY, P32, DOI [10.1002/ uog.5634. 317e317, DOI 10.1002/UOG.5634.317E317]
  • [19] Public Health England, 2018, FET AN SCREEN PROGR
  • [20] An algorithm based on OmniView technology to reconstruct sagittal and coronal planes of the fetal brain from volume datasets acquired by three-dimensional ultrasound
    Rizzo, G.
    Capponi, A.
    Pietrolucci, M. E.
    Capece, A.
    Aiello, E.
    Mammarella, S.
    Arduini, D.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2011, 38 (02) : 158 - 164