Additive noise properties of active matrix flat-panel imagers

被引:62
作者
Maolinbay, M [1 ]
El-Mohri, Y [1 ]
Antonuk, LE [1 ]
Jee, KW [1 ]
Nassif, S [1 ]
Rong, X [1 ]
Zhao, Q [1 ]
机构
[1] Univ Michigan, Med Ctr, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
关键词
additive noise; active matrix flat-panel imager; amorphous silicon; thin-film transistors;
D O I
10.1118/1.1286721
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A detailed theoretical and empirical investigation of additive noise for indirect detection, active matrix hat-panel imagers (AMFPIs) has been performed. Such imagers comprise a pixelated array, incorporating photodiodes and thin-film transistors (TFTs), and an associated electronic acquisition system. A theoretical model of additive noise, defined as the noise of an imaging system in the absence of radiation, has been developed. This model is based upon an equivalent-noise-circuit representation of an AMFPI. The model contains a number of uncorrelated noise components which have been designated as pixel noise, data line thermal noise, externally coupled noise, preamplifier noise and digitization noise. Pixel noise is further divided into the following components: TFT thermal noise, shot and 1/f noise associated with the TFT and photodiode leakage currents, and TFT transient noise. Measurements of various additive noise components were carried out on a prototype imaging system based on a 508 mu m pitch, 26x26 cm(2) array. Other measurements were performed in the absence of the array, involving discrete components connected to the preamplifier input. Overall, model predictions of total additive noise as well as of pixel, preamplifier, and data line thermal noise components were in agreement with results of their measured counterparts. For the imaging system examined, the model predicts that pixel noise is dominated by shot and 1/f noise components of the photodiode and TFT at frame times above similar to 1 s. As frame time decreases, pixel noise is increasingly dominated by TFT thermal noise. Under these conditions, the reasonable degree of agreement observed between measurements and model predictions provides strong evidence that the role of TFT thermal noise has been properly incorporated :into the model. Finally, the role of the resistance and capacitance of array data lines in the model was investigated using discrete component circuits at the preamplifier input. Measurements of preamplifier noise and data line thermal noise components as a function of input capacitance and resistance were found to be in reasonable agreement with model predictions. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01408-5].
引用
收藏
页码:1841 / 1854
页数:14
相关论文
共 24 条
  • [1] Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications
    Antonuk, LE
    Jee, KW
    El-Mohri, Y
    Maolinbay, M
    Nassif, S
    Rong, X
    Zhao, Q
    Siewerdsen, JH
    Street, RA
    Shah, KS
    [J]. MEDICAL PHYSICS, 2000, 27 (02) : 289 - 306
  • [2] Beyond the limits of present active matrix, flat-panel imagers (AMFPIs) for diagnostic radiology
    Antonuk, LE
    El-Mohri, Y
    Jee, KW
    Maolinbay, M
    Nassif, SC
    Rong, XJ
    Siewerdsen, JH
    Zhao, QH
    Street, RA
    [J]. MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 518 - 527
  • [3] ANTONUK LE, 1995, P SOC PHOTO-OPT INS, V2432, P216, DOI 10.1117/12.208340
  • [4] Development of a high resolution, active matrix, flat-panel imager with enhanced fill factor
    Antonuk, LE
    ElMohri, Y
    Huang, W
    Jee, KW
    Maolinbay, M
    Scarpine, VE
    Siewerdsen, JH
    Verma, M
    Yorkston, J
    Street, RA
    [J]. PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 2 - 13
  • [5] Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation
    Antonuk, LE
    ElMohri, Y
    Siewerdsen, JH
    Yorkston, J
    Huang, W
    Scarpine, VE
    Street, RA
    [J]. MEDICAL PHYSICS, 1997, 24 (01) : 51 - 70
  • [6] Initial performance evaluation of an indirect-detection, active matrix flat-panel imager (AMFPI) prototype for megavoltage imaging
    Antonuk, LE
    El-Mohri, Y
    Huang, WD
    Jee, KW
    Siewerdsen, JH
    Maolinbay, M
    Scarpine, VE
    Sandler, H
    Yorkston, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02): : 437 - 454
  • [7] A large-area, 97 μm pitch, indirect-detection, active matrix, flat-panel imager (AMFPI)
    Antonuk, LE
    El-Mohri, Y
    Hall, A
    Jee, KW
    Maolinbay, M
    Nassif, SC
    Rong, XJ
    Siewerdsen, JH
    Zhao, QH
    Weisfield, RL
    [J]. PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 2 - 13
  • [8] BOUDRY JM, 1996, EVALUATION HYDROGENA
  • [9] Flat panel imaging system for fluoroscopy applications
    Colbeth, RE
    Allen, MJ
    Day, DJ
    Gilblom, DL
    Harris, R
    Job, ID
    Klausmeier-Brown, ME
    Pavkovich, J
    Seppi, EJ
    Shapiro, EG
    Wright, MD
    Yu, JM
    [J]. PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 376 - 387
  • [10] Degradation of the detective quantum efficiency due to a non-unity detector fill factor
    Cunningham, IA
    [J]. PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 22 - 31