Cesium ion-selective electrodes based on 1,3-alternate thiacalix[4]biscrown-6,6

被引:34
作者
Choi, Y
Kim, H [1 ]
Lee, JK
Lee, SH
Lim, HB
Kim, JS
机构
[1] Seoul Natl Univ, Sch Chem, Seoul 151747, South Korea
[2] Konyang Univ, Dept Chem, Nonsan 320711, South Korea
[3] Dankook Univ, Inst Nanosensor & Biotechnol, Dept Chem, Seoul 140714, South Korea
关键词
thiacalix[4]biscrown ethers; cesium ion-selective electrode; potentiometry;
D O I
10.1016/j.talanta.2004.04.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Four thiacalix[4]biscrown ethers with 1,3-altemate conformation were examined for the potentiometric responses in poly(vinyl chloride) membrane electrodes. Their potentiometric selectivities toward potassium and cesium ions over other alkali, alkaline earth, and transition metal ions were measured by the fixed interference method (FIM). Among the ionophores, 1,3-alternate thiacalix[4]biscrown-6,6 showed a high selectivity for cesium over potassium ion and so was optimized as a Cs+-selective electrode. The electrode exhibited a linear response with a near Nernstian slope of 57.6 mV per decade in the concentration range of 1.0 x 10(-6) to 3.2 x 10(-2) M. It was suitable for use in aqueous solution in a wide range of pH 2.5-12.5 and had a fast response time of ca. 5 s. On the basis of 1,3-alternate thiacalix[4]biscrown-6,6, the electrode has a wide linear range and selectivity for cesium ion over potassium ion (log K-Cs(+),K+ = -3.7) better than those previously reported with other ionophores. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:975 / 980
页数:6
相关论文
共 42 条
[11]   STUDY OF THE BEHAVIOR OF CALIX[4]ARENE-BASED SODIUM-SELECTIVE ELECTRODES BY MEANS OF ANOVA [J].
CARERI, M ;
CASNATI, A ;
GUARINONI, A ;
MANGIA, A ;
MORI, G ;
POCHINI, A ;
UNGARO, R .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :3156-3160
[12]   SYNTHESIS, COMPLEXATION, AND MEMBRANE-TRANSPORT STUDIES OF 1,3-ALTERNATE CALIX[4]ARENE-CROWN-6 CONFORMERS - A NEW CLASS OF CESIUM SELECTIVE IONOPHORES [J].
CASNATI, A ;
POCHINI, A ;
UNGARO, R ;
UGOZZOLI, F ;
ARNAUD, F ;
FANNI, S ;
SCHWING, MJ ;
EGBERINK, RJM ;
DEJONG, F ;
REINHOUDT, DN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1995, 117 (10) :2767-2777
[13]  
Cecille L., 1991, Radioactive Waste Management and Disposal
[14]   DESIGN AND CHARACTERIZATION OF SODIUM-SELECTIVE OPTODE MEMBRANES BASED ON THE LIPOPHILIC TETRAESTER OF CALIX[4]ARENE [J].
CHAN, WH ;
LEE, AWM ;
LEE, CM ;
YAU, KW ;
WANG, KM .
ANALYST, 1995, 120 (07) :1963-1967
[15]   Silver(I)-selective membrane electrodes based on sulfur-containing podands [J].
Chung, S ;
Kim, W ;
Park, SB ;
Kim, DY ;
Lee, SS .
TALANTA, 1997, 44 (07) :1291-1298
[16]  
COBBEN PLH, 1992, THESIS U TWENTE ENSC
[17]   PVC-based hexathia-18-crown-6-tetraone sensor for mercury(II) ions [J].
Fakhari, AR ;
Ganjali, MR ;
Shamsipur, M .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3693-3696
[18]   POTASSIUM-SELECTIVE AND CESIUM-SELECTIVE PVC MEMBRANE ELECTRODES BASED ON BIS-CROWN ETHERS [J].
FUNG, KW ;
WONG, KH .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1980, 111 (2-3) :359-368
[19]  
GEHRIG PM, 1990, HELV CHIM ACTA, V73, P230
[20]   COMPLEXATION OF ALKALI-METAL CATIONS BY CONFORMATIONALLY RIGID, STEREOISOMERIC CALIX[4]ARENE CROWN ETHERS - A QUANTITATIVE-EVALUATION OF PREORGANIZATION [J].
GHIDINI, E ;
UGOZZOLI, F ;
UNGARO, R ;
HARKEMA, S ;
ABUELFADL, A ;
REINHOUDT, DN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (19) :6979-6985