Evaluation of Uterine Anomalies: 3D FRFSE Cube Versus Standard 2D FRFSE

被引:31
作者
Agrawal, Garima [1 ]
Riherd, Jody M. [1 ]
Busse, Reed F. [1 ,2 ]
Hinshaw, J. Louis [1 ]
Sadowski, Elizabeth A. [1 ]
机构
[1] Univ Wisconsin, Dept Radiol, Sch Med & Publ Hlth, Madison, WI 53792 USA
[2] GE Healthcare, MR Appl Sci Lab, Madison, WI USA
关键词
2D fast-recovery fast spin-echo; 3D fast-recovery fast spin-echo cube; uterine anomalies; FAST SPIN-ECHO; MULLERIAN DUCT ANOMALIES; EXPERIENCE;
D O I
10.2214/AJR.09.2716
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare a novel MRI sequence-3D fast-recovery fast spin-echo (FRFSE) cube-with a standard 2D FRFSE sequence for the investigation of uterine anomalies. CONCLUSION. Compared with 2D FRFSE, 3D FRFSE cube provides superior image quality and improved 3D reconstructions in a shorter acquisition time and enables excellent visualization of uterine anatomy in any orientation, regardless of the original scanning plane.
引用
收藏
页码:W558 / W562
页数:5
相关论文
共 11 条
[1]   Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo [J].
Busse, Reed F. ;
Brau, Anja C. S. ;
Vu, Anthony ;
Michelich, Charles R. ;
Bayram, Ersin ;
Kijowski, Richard ;
Reeder, Scott B. ;
Rowley, Howard A. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) :640-649
[2]   Fast spin echo sequences with very long echo trains:: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast [J].
Busse, RF ;
Hariharan, H ;
Vu, A ;
Brittain, JH .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :1030-1037
[3]  
BUSSE RF, 2007, P INT SOC MAGN RES M
[4]  
Ghagla GH, 2008, INVEST RADIOL, V43, P547
[5]   Isotropic MRI of the knee with 3D fast spin-echo extended echo-train acquisition (XETA): Initial experience [J].
Gold, Garry E. ;
Busse, Reed F. ;
Beehler, Carol ;
Han, Eric ;
Brau, Anja C. S. ;
Beatty, Philip J. ;
Beaulieu, Christopher F. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05) :1287-1293
[6]   Clinical implications of uterine malformations and hysteroscopic treatment results [J].
Grimbizis, GF ;
Camus, M ;
Tarlatzis, BC ;
Bontis, JN ;
Devroey, P .
HUMAN REPRODUCTION UPDATE, 2001, 7 (02) :161-174
[7]   Imaging of Mullerian Duct Anomalies [J].
Olpin, Jeffrey Dee ;
Heilbrun, Marta .
CLINICAL OBSTETRICS AND GYNECOLOGY, 2009, 52 (01) :40-56
[8]   Reproductive performance of women with mullerian anomalies [J].
Rackow, Beth W. ;
Arici, Aydin .
CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2007, 19 (03) :229-237
[9]   Ankle: Isotropic MR Imaging with 3D-FSE-Cube-Initial Experience in Healthy Volunteers [J].
Stevens, Kathryn J. ;
Busse, Reed F. ;
Han, Eric ;
Brau, Anja C. S. ;
Beatty, Philip J. ;
Beaulieu, Christopher F. ;
Gold, Garry E. .
RADIOLOGY, 2008, 249 (03) :1026-1033
[10]   Mullerian duct anomalies: Imaging and clinical issues [J].
Troiano, RN ;
McCarthy, SM .
RADIOLOGY, 2004, 233 (01) :19-34