Image Registration Method for Chest MDCT Images Based on 2-D Finite Element Method

被引:0
作者
Ogimoto, Takuji [1 ]
Kamiya, Tohru [1 ]
Aoki, Takatoshi [2 ]
机构
[1] Kyushu Inst Technol, Dept Mech & Control Engn, Tobata Ku, 1-1 Sensui Cho, Kitakyushu, Fukuoka 8048550, Japan
[2] Univ Occupat & Environm Hlth, 1-1 Iseigaoka, Yahatanishi, Kitakyusyu 8078555, Japan
来源
PROCEEDINGS OF THE 2021 INTERNATIONAL CONFERENCE ON ARTIFICIAL LIFE AND ROBOTICS (ICAROB 2021) | 2021年
关键词
Computer Aided Diagnosis System; Temporal Subtraction Technique; Non-Rigid Image Registration; Finite Element Method; SUBTRACTION;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Multi detector-row computed tomography (MDCT) device has been used for early detection of lung cancer. However, there is concern that an increase in the burden on doctors will be caused by improvements in CT performance. Therefore, developing a computer aided diagnosis (CAD) reduces the burden on doctors. A temporal subtraction (TS) technique is one of the CAD systems and it is the subtraction operation of the current image and the previous one of the same patients that emphasizes temporal changes. In the TS image, when the position of the current image and the previous image are misaligned, subtraction artifacts are remained. In this paper, we propose a registration method based on the 2-D finite element method (FEM). In our proposed method, to improve the high computed cost that is the biggest problem of the FEM, we introduce the 2D FEM registration. We applied this method to 31 series MDCT image sets which was obtained previous and current from the same subjects and evaluated. As a result, full width at half maximum (FWHM) of 28.0, artifact to lung volume ratio of 5.77% and computational time of 140 sec were obtained.
引用
收藏
页码:144 / 147
页数:4
相关论文
共 7 条
  • [1] Temporal Subtraction Method for Lung Nodule Detection on Successive Thoracic CT Soft-Copy Images1
    Aoki, Takatoshi
    Murakami, Seiichi
    Kim, Hyoungseop
    Fujii, Masami
    Takahashi, Hiroyuki
    Oki, Hodaka
    Hayashida, Yoshiko
    Katsuragawa, Shigehiko
    Shiraishi, Junji
    Korogi, Yukunori
    [J]. RADIOLOGY, 2014, 271 (01) : 255 - 261
  • [2] CHEW LP, 1989, ALGORITHMICA, V4, P97, DOI 10.1007/BF01553881
  • [3] Current status and future potential of computer-aided diagnosis in medical imaging
    Doi, K
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2005, 78 : S3 - S19
  • [4] Ferrant M, 1999, LECT NOTES COMPUT SC, V1679, P202
  • [5] Development of a Voxel-Matching Technique for Substantial Reduction of Subtraction Artifacts in Temporal Subtraction Images Obtained from Thoracic MDCT
    Itai, Yoshinori
    Kim, Hyoungseop
    Ishikawa, Seiji
    Katsuragawa, Shigehiko
    Doi, Kunio
    [J]. JOURNAL OF DIGITAL IMAGING, 2010, 23 (01) : 31 - 38
  • [6] DIGITAL IMAGE SUBTRACTION OF TEMPORALLY SEQUENTIAL CHEST IMAGES FOR DETECTION OF INTERVAL CHANGE
    KANO, A
    DOI, K
    MACMAHON, H
    HASSELL, DD
    GIGER, ML
    [J]. MEDICAL PHYSICS, 1994, 21 (03) : 453 - 461