Accelerated dual-venc 4D flow MRI for neurovascular applications

被引:89
|
作者
Schnell, Susanne [1 ]
Ansari, Sameer A. [1 ,2 ]
Wu, Can [1 ,3 ]
Garcia, Julio [1 ,4 ]
Murphy, Ian G. [1 ]
Rahman, Ozair A. [1 ]
Rahsepar, Amir A. [1 ]
Aristova, Maria [1 ]
Collins, Jeremy D. [1 ]
Carr, James C. [1 ]
Markl, Michael [1 ,2 ]
机构
[1] Northwestern Univ, Dept Radiol, Feinberg Sch Med, 737 N Michigan Ave,Ste 1600, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Neurosurg, 737 N Michigan Ave,Ste 1600, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Biomed Engn, McCormick Sch Engn, 737 N Michigan Ave,Ste 1600, Chicago, IL 60611 USA
[4] Univ Calgary, Cumming Sch Med, Stephenson Cardiac Imaging Ctr, Dept Cardiac Sci, Calgary, AB, Canada
关键词
4D flow MRI; dual venc; intracranial 4D flow MRI; PC-MRI; k-t GRAPPA; K-T-GRAPPA; COMPUTATIONAL FLUID-DYNAMICS; PHASE-CONTRAST MRI; WALL SHEAR-STRESS; 3D BLOOD-FLOW; IN-VIVO; VELOCITY; TIME; QUANTIFICATION; HEMODYNAMICS;
D O I
10.1002/jmri.25595
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo improve velocity-to-noise ratio (VNR) and dynamic velocity range of 4D flow magnetic resonance imaging (MRI) by using dual-velocity encoding (dual-venc) with k-t generalized autocalibrating partially parallel acquisition (GRAPPA) acceleration. Materials and MethodsA dual-venc 4D flow MRI sequence with k-t GRAPPA acceleration was developed using a shared reference scan followed by three-directional low- and high-venc scans (repetition time / echo time / flip angle=6.1 msec / 3.4 msec / 15 degrees, temporal/spatial resolution=43.0 msec/1.2 x 1.2 x 1.2mm(3)). The high-venc data were used to correct for aliasing in the low-venc data, resulting in a single dataset with the favorable VNR of the low-venc but without velocity aliasing. The sequence was validated with a 3T MRI scanner in phantom experiments and applied in 16 volunteers to investigate its feasibility for assessing intracranial hemodynamics (net flow and peak velocity) at the major intracranial vessels. In addition, image quality and image noise were assessed in the in vivo acquisitions. ResultsAll 4D flow MRI scans were acquired successfully with an acquisition time of 204 minutes. The shared reference scan reduced the total acquisition time by 12.5% compared to two separate scans. Phantom experiments showed 51.4% reduced noise for dual-venc compared to high-venc and an excellent agreement of velocities (=0.8, P < 0.001). The volunteer data showed decreased noise in dual-venc data (54.6% lower) compared to high-venc, and improved image quality, as graded by two observers: fewer artifacts (P < 0.0001), improved vessel conspicuity (P < 0.0001), and reduced noise (P < 0.0001). ConclusionDual-venc 4D flow MRI exhibits the superior VNR of the low-venc acquisition and reliably incorporates low- and high-velocity fields simultaneously. In vitro and in vivo data demonstrate improved flow visualization, image quality, and image noise. Level of Evidence: 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:102-114
引用
收藏
页码:102 / 114
页数:13
相关论文
共 50 条
  • [41] Fast Interactive Exploration of 4D MRI Flow Data
    Hennemuth, A.
    Friman, O.
    Schumann, C.
    Bock, J.
    Drexl, J.
    Huellebrand, M.
    Markl, M.
    Peitgen, H. -O.
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [42] The Role of Imaging of Flow Patterns by 4D Flow MRI in Aortic Stenosis
    Garcia, Julio
    Barker, Alex J.
    Markl, Michael
    JACC-CARDIOVASCULAR IMAGING, 2019, 12 (02) : 252 - 266
  • [43] High Spatiotemporal Resolution 4D Flow MRI of Intracranial Aneurysms at 7T in 10 Minutes
    Gottwald, L. M.
    Toger, J.
    Bloch, K. Markenroth
    Peper, E. S.
    Coolen, B. F.
    Strijkers, G. J.
    van Ooij, P.
    Nederveen, A. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2020, 41 (07) : 1201 - 1208
  • [44] A COMPREHENSIVE REVIEW OF 4D FLOW MRI AND CFD IN CARDIOVASCULAR AND CONGENITAL HEART DISEASE
    El Nihum, Lamees
    Chinnadurai, Ponraj
    Lin, C. Huie
    Banerjee, Debjyoti
    PROCEEDINGS OF ASME 2021 FLUIDS ENGINEERING DIVISION SUMMER MEETING (FEDSM2021), VOL 1, 2021,
  • [45] Novel and facile criterion to assess the accuracy of WSS estimation by 4D flow MRI
    Ko, Seungbin
    Yang, Byungkuen
    Cho, Jee-Hyun
    Lee, Jeesoo
    Song, Simon
    MEDICAL IMAGE ANALYSIS, 2019, 53 : 95 - 103
  • [46] K-t GRAPPA-accelerated 4D flow MRI of liver hemodynamics: influence of different acceleration factors on qualitative and quantitative assessment of blood flow
    Zoran Stankovic
    Jury Fink
    Jeremy D. Collins
    Edouard Semaan
    Maximilian F. Russe
    James C. Carr
    Michael Markl
    Mathias Langer
    Bernd Jung
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2015, 28 : 149 - 159
  • [47] Towards quantitative evaluation of wall shear stress from 4D flow imaging
    Levilly, Sebastien
    Castagna, Marco
    Idier, Jerome
    Bonnefoy, Felicien
    Le Touze, David
    Moussaoui, Said
    Paul-Gilloteaux, Perrine
    Serfaty, Jean-Michel
    MAGNETIC RESONANCE IMAGING, 2020, 74 : 232 - 243
  • [48] Identification of Vortex Cores in Cerebral Aneurysms on 4D Flow MRI
    Futami, K.
    Uno, T.
    Misaki, K.
    Tamai, S.
    Nambu, I
    Uchiyama, N.
    Nakada, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (12) : 2111 - 2116
  • [49] Cerebral Sinus Hemodynamics in Adults Revealed by 4D Flow MRI
    Dai, Chihang
    Zhao, Pengfei
    Ding, Heyu
    Lv, Han
    Qiu, Xiaoyu
    Tang, Ruowei
    Xu, Ning
    Huang, Yan
    Han, Xu
    Yang, Zhenghan
    Wang, Zhenchang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (04) : 1706 - 1717
  • [50] Highly accelerated compressed sensing 4D flow MRI in congenital and acquired heart disease: comparison of aorta and main pulmonary artery flow parameters with conventional 4D flow MRI in children and young adults
    Sodhi, Aparna
    Markl, Michael
    Popescu, Andrada R.
    Griffin, Lindsay M.
    Robinson, Joshua D.
    Rigsby, Cynthia K.