Accelerated dual-venc 4D flow MRI for neurovascular applications

被引:89
|
作者
Schnell, Susanne [1 ]
Ansari, Sameer A. [1 ,2 ]
Wu, Can [1 ,3 ]
Garcia, Julio [1 ,4 ]
Murphy, Ian G. [1 ]
Rahman, Ozair A. [1 ]
Rahsepar, Amir A. [1 ]
Aristova, Maria [1 ]
Collins, Jeremy D. [1 ]
Carr, James C. [1 ]
Markl, Michael [1 ,2 ]
机构
[1] Northwestern Univ, Dept Radiol, Feinberg Sch Med, 737 N Michigan Ave,Ste 1600, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Neurosurg, 737 N Michigan Ave,Ste 1600, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Biomed Engn, McCormick Sch Engn, 737 N Michigan Ave,Ste 1600, Chicago, IL 60611 USA
[4] Univ Calgary, Cumming Sch Med, Stephenson Cardiac Imaging Ctr, Dept Cardiac Sci, Calgary, AB, Canada
关键词
4D flow MRI; dual venc; intracranial 4D flow MRI; PC-MRI; k-t GRAPPA; K-T-GRAPPA; COMPUTATIONAL FLUID-DYNAMICS; PHASE-CONTRAST MRI; WALL SHEAR-STRESS; 3D BLOOD-FLOW; IN-VIVO; VELOCITY; TIME; QUANTIFICATION; HEMODYNAMICS;
D O I
10.1002/jmri.25595
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo improve velocity-to-noise ratio (VNR) and dynamic velocity range of 4D flow magnetic resonance imaging (MRI) by using dual-velocity encoding (dual-venc) with k-t generalized autocalibrating partially parallel acquisition (GRAPPA) acceleration. Materials and MethodsA dual-venc 4D flow MRI sequence with k-t GRAPPA acceleration was developed using a shared reference scan followed by three-directional low- and high-venc scans (repetition time / echo time / flip angle=6.1 msec / 3.4 msec / 15 degrees, temporal/spatial resolution=43.0 msec/1.2 x 1.2 x 1.2mm(3)). The high-venc data were used to correct for aliasing in the low-venc data, resulting in a single dataset with the favorable VNR of the low-venc but without velocity aliasing. The sequence was validated with a 3T MRI scanner in phantom experiments and applied in 16 volunteers to investigate its feasibility for assessing intracranial hemodynamics (net flow and peak velocity) at the major intracranial vessels. In addition, image quality and image noise were assessed in the in vivo acquisitions. ResultsAll 4D flow MRI scans were acquired successfully with an acquisition time of 204 minutes. The shared reference scan reduced the total acquisition time by 12.5% compared to two separate scans. Phantom experiments showed 51.4% reduced noise for dual-venc compared to high-venc and an excellent agreement of velocities (=0.8, P < 0.001). The volunteer data showed decreased noise in dual-venc data (54.6% lower) compared to high-venc, and improved image quality, as graded by two observers: fewer artifacts (P < 0.0001), improved vessel conspicuity (P < 0.0001), and reduced noise (P < 0.0001). ConclusionDual-venc 4D flow MRI exhibits the superior VNR of the low-venc acquisition and reliably incorporates low- and high-velocity fields simultaneously. In vitro and in vivo data demonstrate improved flow visualization, image quality, and image noise. Level of Evidence: 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:102-114
引用
收藏
页码:102 / 114
页数:13
相关论文
共 50 条
  • [31] 4D flow imaging with MRI
    Stankovic, Zoran
    Allen, Bradley D.
    Garcia, Julio
    Jarvis, Kelly B.
    Markl, Michael
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2014, 4 (02) : 173 - 192
  • [32] Highly accelerated intracranial 4D flow MRI: evaluation of healthy volunteers and patients with intracranial aneurysms
    Liu, Jing
    Koskas, Louise
    Faraji, Farshid
    Kao, Evan
    Wang, Yan
    Haraldsson, Henrik
    Kefayati, Sarah
    Zhu, Chengcheng
    Ahn, Sinyeob
    Laub, Gerhard
    Saloner, David
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2018, 31 (02) : 295 - 307
  • [33] Emerging Applications of Abdominal 4D Flow MRI
    Roldan-Alzate, Alejandro
    Francois, Christopher J.
    Wieben, Oliver
    Reeder, Scott B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 58 - 66
  • [34] A Dual-VENC Four-Dimensional Flow MRI Framework for Analysis of Subject-Specific Heterogeneous Nonlinear Vessel Deformation
    Concannon, J.
    Hynes, N.
    McMullen, M.
    Smyth, E.
    Moerman, K.
    McHugh, P. E.
    Sultan, S.
    Karmonik, C.
    McGarry, J. P.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (11):
  • [35] 4D Flow MRI in the portal venous system: imaging and analysis methods, and clinical applications
    Hyodo, Ryota
    Takehara, Yasuo
    Naganawa, Shinji
    RADIOLOGIA MEDICA, 2022, 127 (11): : 1181 - 1198
  • [36] Comparison of 4D Flow MRI to 2D Flow MRI in the pulmonary arteries in healthy volunteers and patients with pulmonary hypertension
    Sieren, Malte Maria
    Berlin, Clara
    Oechtering, Thekla Helene
    Hunold, Peter
    Droemann, Daniel
    Barkhausen, Jorg
    Frydrychowicz, Alex
    PLOS ONE, 2019, 14 (10):
  • [37] Comparison of turbulent flow measurement schemes for 4D flow MRI
    Hoijn Ha
    Hanwook Park
    Journal of Visualization, 2019, 22 : 541 - 553
  • [38] 4D flow MRI hemodynamic biomarkers for cerebrovascular diseases
    Wahlin, Anders
    Eklund, Anders
    Malm, Jan
    JOURNAL OF INTERNAL MEDICINE, 2022, 291 (02) : 115 - 127
  • [39] 4D flow MRI applications in congenital heart disease
    Judy Rizk
    European Radiology, 2021, 31 : 1160 - 1174
  • [40] Assessment of arterial pulsatility of cerebral perforating arteries using 7T high-resolution dual-VENC phase-contrast MRI
    Tang, Jianing
    Pahlavian, Soroush Heidari
    Joe, Elizabeth
    Gamez, Maria Tereza
    Zhao, Tianrui
    Ma, Samantha J.
    Jin, Jin
    Cen, Steven Yong
    Chui, Helena C.
    Yan, Lirong
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (02) : 605 - 617