Accelerated dual-venc 4D flow MRI for neurovascular applications

被引:89
|
作者
Schnell, Susanne [1 ]
Ansari, Sameer A. [1 ,2 ]
Wu, Can [1 ,3 ]
Garcia, Julio [1 ,4 ]
Murphy, Ian G. [1 ]
Rahman, Ozair A. [1 ]
Rahsepar, Amir A. [1 ]
Aristova, Maria [1 ]
Collins, Jeremy D. [1 ]
Carr, James C. [1 ]
Markl, Michael [1 ,2 ]
机构
[1] Northwestern Univ, Dept Radiol, Feinberg Sch Med, 737 N Michigan Ave,Ste 1600, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Neurosurg, 737 N Michigan Ave,Ste 1600, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Biomed Engn, McCormick Sch Engn, 737 N Michigan Ave,Ste 1600, Chicago, IL 60611 USA
[4] Univ Calgary, Cumming Sch Med, Stephenson Cardiac Imaging Ctr, Dept Cardiac Sci, Calgary, AB, Canada
关键词
4D flow MRI; dual venc; intracranial 4D flow MRI; PC-MRI; k-t GRAPPA; K-T-GRAPPA; COMPUTATIONAL FLUID-DYNAMICS; PHASE-CONTRAST MRI; WALL SHEAR-STRESS; 3D BLOOD-FLOW; IN-VIVO; VELOCITY; TIME; QUANTIFICATION; HEMODYNAMICS;
D O I
10.1002/jmri.25595
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo improve velocity-to-noise ratio (VNR) and dynamic velocity range of 4D flow magnetic resonance imaging (MRI) by using dual-velocity encoding (dual-venc) with k-t generalized autocalibrating partially parallel acquisition (GRAPPA) acceleration. Materials and MethodsA dual-venc 4D flow MRI sequence with k-t GRAPPA acceleration was developed using a shared reference scan followed by three-directional low- and high-venc scans (repetition time / echo time / flip angle=6.1 msec / 3.4 msec / 15 degrees, temporal/spatial resolution=43.0 msec/1.2 x 1.2 x 1.2mm(3)). The high-venc data were used to correct for aliasing in the low-venc data, resulting in a single dataset with the favorable VNR of the low-venc but without velocity aliasing. The sequence was validated with a 3T MRI scanner in phantom experiments and applied in 16 volunteers to investigate its feasibility for assessing intracranial hemodynamics (net flow and peak velocity) at the major intracranial vessels. In addition, image quality and image noise were assessed in the in vivo acquisitions. ResultsAll 4D flow MRI scans were acquired successfully with an acquisition time of 204 minutes. The shared reference scan reduced the total acquisition time by 12.5% compared to two separate scans. Phantom experiments showed 51.4% reduced noise for dual-venc compared to high-venc and an excellent agreement of velocities (=0.8, P < 0.001). The volunteer data showed decreased noise in dual-venc data (54.6% lower) compared to high-venc, and improved image quality, as graded by two observers: fewer artifacts (P < 0.0001), improved vessel conspicuity (P < 0.0001), and reduced noise (P < 0.0001). ConclusionDual-venc 4D flow MRI exhibits the superior VNR of the low-venc acquisition and reliably incorporates low- and high-velocity fields simultaneously. In vitro and in vivo data demonstrate improved flow visualization, image quality, and image noise. Level of Evidence: 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:102-114
引用
收藏
页码:102 / 114
页数:13
相关论文
共 50 条
  • [21] 4D flow MRI
    Markl, Michael
    Frydrychowicz, Alex
    Kozerke, Sebastian
    Hope, Mike
    Wieben, Oliver
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (05) : 1015 - 1036
  • [22] Abdominal Applications of 4D Flow MRI
    Riedel, Christoph
    Lenz, Alexander
    Fischer, Lutz
    Li, Jun
    Piecha, Feilix
    Kluwe, Johannes
    Adam, Gerhard
    Bannas, Peter
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (04): : 388 - 398
  • [23] Accelerated sequences of 4D flow MRI using GRAPPA and compressed sensing: A comparison against conventional MRI and computational fluid dynamics
    Garreau, Morgane
    Puiseux, Thomas
    Toupin, Solenn
    Giese, Daniel
    Mendez, Simon
    Nicoud, Franck
    Moreno, Ramiro
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (06) : 2432 - 2446
  • [24] Validation of two accelerated 4D flow MRI sequences at 3 T: a phantom study
    Ebel, Sebastian
    Huebner, Lisa
    Koehler, Benjamin
    Kropf, Siegfried
    Preim, Bernhard
    Jung, Bernd
    Grothoff, Matthias
    Gutberlet, Matthias
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2019, 3 (01) : 10
  • [25] Technical Background for 4D Flow MR Imaging
    Terada, Masaki
    Takehara, Yasuo
    Isoda, Haruo
    Wakayama, Tetsuya
    Nozaki, Atsushi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (02) : 267 - 277
  • [26] Intracardiac Flow at 4D CT: Comparison with 4D Flow MRI
    Lantz, Jonas
    Gupta, Vikas
    Henriksson, Lilian
    Karlsson, Matts
    Persson, Anders
    Carlhall, Carl-Johan
    Ebbers, Tino
    RADIOLOGY, 2018, 289 (01) : 51 - 58
  • [27] The role of 4D flow MRI for clinical applications in cardiovascular disease: current status and future perspectives
    Zhuang, Baiyan
    Sirajuddin, Arlene
    Zhao, Shihua
    Lu, Minjie
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (09) : 4193 - 4210
  • [28] Optimizing encoding strategies for 4D Flow MRI of mean and turbulent flow
    Dirix, Pietro
    Buoso, Stefano
    Kozerke, Sebastian
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [29] Validation of numerical simulation methods in aortic arch using 4D Flow MRI
    Miyazaki, Shohei
    Itatani, Keiichi
    Furusawa, Toyoki
    Nishino, Teruyasu
    Sugiyama, Masataka
    Takehara, Yasuo
    Yasukochi, Satoshi
    HEART AND VESSELS, 2017, 32 (08) : 1032 - 1044
  • [30] Modeling Bias Error in 4D Flow MRI Velocity Measurements
    Rothenberger, Sean M.
    Zhang, Jiacheng
    Brindise, Melissa C.
    Schnell, Susanne
    Markl, Michael
    Vlachos, Pavlos P.
    Rayz, Vitaliy L.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (07) : 1802 - 1812