Accelerated dual-venc 4D flow MRI for neurovascular applications
被引:89
|作者:
Schnell, Susanne
[1
]
Ansari, Sameer A.
[1
,2
]
Wu, Can
[1
,3
]
Garcia, Julio
[1
,4
]
Murphy, Ian G.
[1
]
Rahman, Ozair A.
[1
]
Rahsepar, Amir A.
[1
]
Aristova, Maria
[1
]
Collins, Jeremy D.
[1
]
Carr, James C.
[1
]
Markl, Michael
[1
,2
]
机构:
[1] Northwestern Univ, Dept Radiol, Feinberg Sch Med, 737 N Michigan Ave,Ste 1600, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Neurosurg, 737 N Michigan Ave,Ste 1600, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Biomed Engn, McCormick Sch Engn, 737 N Michigan Ave,Ste 1600, Chicago, IL 60611 USA
[4] Univ Calgary, Cumming Sch Med, Stephenson Cardiac Imaging Ctr, Dept Cardiac Sci, Calgary, AB, Canada
关键词:
4D flow MRI;
dual venc;
intracranial 4D flow MRI;
PC-MRI;
k-t GRAPPA;
K-T-GRAPPA;
COMPUTATIONAL FLUID-DYNAMICS;
PHASE-CONTRAST MRI;
WALL SHEAR-STRESS;
3D BLOOD-FLOW;
IN-VIVO;
VELOCITY;
TIME;
QUANTIFICATION;
HEMODYNAMICS;
D O I:
10.1002/jmri.25595
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
PurposeTo improve velocity-to-noise ratio (VNR) and dynamic velocity range of 4D flow magnetic resonance imaging (MRI) by using dual-velocity encoding (dual-venc) with k-t generalized autocalibrating partially parallel acquisition (GRAPPA) acceleration. Materials and MethodsA dual-venc 4D flow MRI sequence with k-t GRAPPA acceleration was developed using a shared reference scan followed by three-directional low- and high-venc scans (repetition time / echo time / flip angle=6.1 msec / 3.4 msec / 15 degrees, temporal/spatial resolution=43.0 msec/1.2 x 1.2 x 1.2mm(3)). The high-venc data were used to correct for aliasing in the low-venc data, resulting in a single dataset with the favorable VNR of the low-venc but without velocity aliasing. The sequence was validated with a 3T MRI scanner in phantom experiments and applied in 16 volunteers to investigate its feasibility for assessing intracranial hemodynamics (net flow and peak velocity) at the major intracranial vessels. In addition, image quality and image noise were assessed in the in vivo acquisitions. ResultsAll 4D flow MRI scans were acquired successfully with an acquisition time of 204 minutes. The shared reference scan reduced the total acquisition time by 12.5% compared to two separate scans. Phantom experiments showed 51.4% reduced noise for dual-venc compared to high-venc and an excellent agreement of velocities (=0.8, P < 0.001). The volunteer data showed decreased noise in dual-venc data (54.6% lower) compared to high-venc, and improved image quality, as graded by two observers: fewer artifacts (P < 0.0001), improved vessel conspicuity (P < 0.0001), and reduced noise (P < 0.0001). ConclusionDual-venc 4D flow MRI exhibits the superior VNR of the low-venc acquisition and reliably incorporates low- and high-velocity fields simultaneously. In vitro and in vivo data demonstrate improved flow visualization, image quality, and image noise. Level of Evidence: 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:102-114