MRF-ZOOM for the unbalanced steady-state free precession (ubSSFP) magnetic resonance fingerprinting

被引:0
|
作者
Wang, Ze [1 ]
Cui, Di [2 ]
Zhang, Jian [3 ]
Wu, Ed X. [4 ]
Hui, Edward S. [2 ]
机构
[1] Univ Maryland, Sch Med, Dept Diagnost Radiol & Nucl Med, Baltimore, MD 21201 USA
[2] Univ Hong Kong, Dept Diagnost Radiol, Hong Kong, Peoples R China
[3] Hangzhou Normal Univ, Dept Phys, Hangzhou, Zhejiang, Peoples R China
[4] Univ Hong Kong, Dept Elect & Elect Engn, Hong Kong, Peoples R China
关键词
Magnetic resonance fingerprinting; Fast searching; ubSSFP; FISP; T1; T2;
D O I
10.1016/j.mri.2019.11.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In magnetic resonance fingerprinting (MRF), tissue parameters are determined by finding the best-match to the acquired MR signal from a predefined signal dictionary. This dictionary searching (DS) process is generally performed in an exhaustive manner, which requires a large predefined dictionary and long searching time. A fast MRF DS algorithm, MRF-ZOOM, was recently proposed based on DS objective function optimization. As a proof-of-concept study, MRF-ZOOM was only tested with one of the earliest MRF sequences but not with the recently more popular unbalanced steady state free precession MRF sequence (MRF-ubSSFP, or MRF-FISP). Meanwhile noise effects on MRF and MRF-ZOOM have not been examined. The purpose of this study was to address these open questions and to verify whether MRF-ZOOM can be combined with a dictionary-compression based method to gain further speed. Numerical simulations were performed to evaluate the DS objective function properties, noise effects on MRF, and to compare MRF-ZOOM with other methods in terms of speed and accuracy. In-vivo experiments were performed as well. Evaluation results showed that premises of MRF-ZOOM held for MRF-FISP; noise did not affect MRF-ZOOM more than the conventional MRF method; when SNR >= 1, MRF quantification yielded accurate results. Dictionary compression introduced quantification errors more to T2 quantification. MRF-ZOOM was thousands of times faster than the conventional MRF method. Combining MRF-ZOOM with dictionary compression showed no benefit in terms of fitting speed. In conclusion, MRF-ZOOM is valid for MRFFISP, and can remarkably save MRF dictionary generation and searching time without sacrificing matching accuracy.
引用
收藏
页码:146 / 154
页数:9
相关论文
共 50 条
  • [1] Magnetic Resonance Fingerprinting Using a Fast Dictionary Searching Algorithm: MRF-ZOOM
    Wang, Ze
    Zhang, Jian
    Cui, Di
    Xie, Jun
    Lyu, Mengye
    Hui, Edward S.
    Wu, Ed. X.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (06) : 1526 - 1535
  • [2] STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE
    CARR, HY
    PHYSICAL REVIEW, 1958, 112 (05): : 1693 - 1701
  • [3] STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE
    CARR, HY
    PHYSICAL REVIEW LETTERS, 1958, 1 (11) : 429 - 430
  • [4] Pseudo Steady-State Free Precession for MR-Fingerprinting
    Asslaender, Jakob
    Glaser, Steffen J.
    Hennig, Juergen
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) : 1151 - 1161
  • [5] Quantitative analysis using steady-state free precession nuclear magnetic resonance
    Azeredo, RBD
    Colnago, LA
    Engelsberg, M
    ANALYTICAL CHEMISTRY, 2000, 72 (11) : 2401 - 2405
  • [6] Physiological and Functional Magnetic Resonance Imaging Using Balanced Steady-state Free Precession
    Park, Sung-Hong
    Han, Paul Kyu
    Choi, Seung Hong
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (03) : 550 - 559
  • [7] Morphing steady-state free precession
    Bieri, O.
    Patil, S.
    Quick, H. H.
    Scheffler, K.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) : 1242 - 1248
  • [8] Reference right atrial function determined by steady-state free precession cardiovascular magnetic resonance
    Sievers, Burkhard
    Addo, Marvin
    Breuckmann, Frank
    Barkhausen, Joerg
    Erbel, Raimund
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2007, 9 (05) : 807 - 814
  • [9] Whole-heart steady-state free precession coronary artery magnetic resonance angiography
    Weber, OM
    Martin, AJ
    Higgins, CB
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (06) : 1223 - 1228