Assessing glycemia in type 1 diabetic patients using a microdialysis system for continuous glucose monitoring

被引:6
|
作者
Radman, Maja
Jurisic, Dubravka
Ljutic, Dragan
Lerkovic, Romana
Kovacic, Natasa
Hozo, Izet Salih
机构
[1] Clin Hosp Split, Dept Internal Med, Gastroenterol & Hepatol Unit, Split, Croatia
[2] Clin Hosp Split, Dept Internal Med, Endocrinol Unit, Split, Croatia
[3] Clin Hosp Split, Dept Internal Med, Nephrol Unit, Split, Croatia
[4] Clin Hosp Ctr, Dept Internal Med, Endocrinol Unit, Rijeka, Croatia
[5] Univ Rijeka, Dept Anat, Fac Med, Rijeka, Croatia
[6] Diagnostics, Florence, Italy
关键词
D O I
10.5144/0256-4947.2007.166
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Continuous glucose monitoring systems can monitor moment-to-moment changes in blood glucose concentration, which cannot be detected by intermittent self-monitoring. Continuing monitoring systems may lead to improved glycemic control. We evaluated a microdialysis technique for improving glycemic control in type 1 diabetes patients treated by different means of basal insulin substitution. PATIENTS AND METHODS: Fifty-two type I diabetic patients on twice daily NPH and pre-meal aspart insulin were randomized in two groups: the continuation of NPH (n=26) (group 1) or once daily glargine (n=26) (group 2). 48-hour GlucoDay registrations were started at the beginning and after 4 months. RESULTS: At baseline, time spent in the euglycemic range (glucose between 3.9 and 8.0 mmol/L) was 37.96 +/- 6.81% for the NPH group and 35.83 +/- 6.240% for the glargine group. At endpoint, time in the euglycemic range increased in both groups (51.02 +/- 7.22% and 57.29 +/- 10.27%, P<0.001 vs. before treatment for both groups). Time spent in the hypoglycernic range (glucose <3.9 mmol/L) was 9.98 +/- 2.57% for the first group and 10.24 +/- 3.55% for the second group at baseline. At endpoint, time in the hypoglycernic range decreased in both groups (8.00 +/- 2.13% and 6.59 +/- 2.04%, P<0.001 vs. before treatment for both groups). CONCLUSION: The analysis of the GlucoDay data gave us information about glycemia other than HbA1c and self-monitoring of blood glucose, such us a peakless activity profile and the lower percentage of time spent in the hypoglycernic range in the glargine-treated group.
引用
收藏
页码:166 / 170
页数:5
相关论文
共 50 条
  • [41] INVIVO CONTINUOUS MONITORING OF GLUCOSE BY MICRODIALYSIS AND A GLUCOSE BIOSENSOR
    MASCINI, M
    MOSCONE, D
    BERNARDI, L
    SENSORS AND ACTUATORS B-CHEMICAL, 1992, 6 (1-3) : 143 - 145
  • [42] Continuous Glucose Monitoring in the Patients with Diabetic Nephropathy
    王锋
    程东生
    汪年松
    李文卉
    包玉倩
    周健
    贾伟平
    JournalofShanghaiJiaotongUniversity(Science), 2011, 16 (04) : 508 - 512
  • [43] Continuous glucose monitoring in the patients with diabetic nephropathy
    Wang F.
    Cheng D.-S.
    Wang N.-S.
    Li W.-H.
    Bao Y.-Q.
    Zhou J.
    Jia W.-P.
    Journal of Shanghai Jiaotong University (Science), 2011, 16 (4) : 508 - 512
  • [44] Glycaemic control in type 2 diabetic patients on chronic haemodialysis: use of a continuous glucose monitoring system
    Riveline, Jean-Pierre
    Teynie, Julie
    Belmouaz, Simohamed
    Franc, Sylvia
    Dardari, Dured
    Bauwens, Marc
    Caudwell, Valerie
    Ragot, Stephanie
    Bridoux, Frank
    Charpentier, Guillaume
    Marechaud, Richard
    Hadjadj, Samy
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2009, 24 (09) : 2866 - 2871
  • [45] Use of continuous glucose monitoring system in patients with type 2 mellitus diabetic during hemodialysis treatment
    Nasser Hissa, Marcelo Rocha
    Gomes Hissa, Priscilla Nogueira
    Botelho Guimaraes, Sergio
    Nasser Hissa, Miguel
    DIABETOLOGY & METABOLIC SYNDROME, 2021, 13 (01):
  • [46] Use of continuous glucose monitoring system in patients with type 2 mellitus diabetic during hemodialysis treatment
    Marcelo Rocha Nasser Hissa
    Priscilla Nogueira Gomes Hissa
    Sérgio Botelho Guimarães
    Miguel Nasser Hissa
    Diabetology & Metabolic Syndrome, 13
  • [47] Performance of a Microdialysis-Based Continuous Glucose Monitoring (CGM) System
    Zijlstra, Eric
    Heise, Tim
    Kuennecke, Wolfgang
    DIABETES, 2012, 61 : A2 - A2
  • [48] Performance of a microdialysis-based continuous glucose monitoring (CGM) system
    Zijlstra, E.
    Heise, T.
    Kuennecke, W.
    DIABETOLOGIA, 2012, 55 : S429 - S429
  • [49] Development of a fuzzy expert system for the control of glycemia in type 1 diabetic patients
    Nobile, Leonardo
    Cosenza, Bartolomeo
    Amato, Marco
    Guarnotta, Valentina
    Giordano, Carla
    Galluzzo, Aldo
    Galluzzo, Mose
    21ST EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, 2011, 29 : 1568 - 1572
  • [50] Microdialysis monitoring of glucose, lactate, glycerol, and pyruvate in patients with diabetic ketoacidosis
    Ciechanowska, Anna
    Ladyzynski, Piotr
    Wojcicki, Jan M.
    Sabalinska, Stanislawa
    Krzymien, Janusz
    Pulawska, Elzbieta
    Karnafel, Waldemar
    Foltynski, Piotr
    Kawiak, Jerzy
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2013, 36 (12): : 869 - 877