Assessing glycemia in type 1 diabetic patients using a microdialysis system for continuous glucose monitoring

被引:6
|
作者
Radman, Maja
Jurisic, Dubravka
Ljutic, Dragan
Lerkovic, Romana
Kovacic, Natasa
Hozo, Izet Salih
机构
[1] Clin Hosp Split, Dept Internal Med, Gastroenterol & Hepatol Unit, Split, Croatia
[2] Clin Hosp Split, Dept Internal Med, Endocrinol Unit, Split, Croatia
[3] Clin Hosp Split, Dept Internal Med, Nephrol Unit, Split, Croatia
[4] Clin Hosp Ctr, Dept Internal Med, Endocrinol Unit, Rijeka, Croatia
[5] Univ Rijeka, Dept Anat, Fac Med, Rijeka, Croatia
[6] Diagnostics, Florence, Italy
关键词
D O I
10.5144/0256-4947.2007.166
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Continuous glucose monitoring systems can monitor moment-to-moment changes in blood glucose concentration, which cannot be detected by intermittent self-monitoring. Continuing monitoring systems may lead to improved glycemic control. We evaluated a microdialysis technique for improving glycemic control in type 1 diabetes patients treated by different means of basal insulin substitution. PATIENTS AND METHODS: Fifty-two type I diabetic patients on twice daily NPH and pre-meal aspart insulin were randomized in two groups: the continuation of NPH (n=26) (group 1) or once daily glargine (n=26) (group 2). 48-hour GlucoDay registrations were started at the beginning and after 4 months. RESULTS: At baseline, time spent in the euglycemic range (glucose between 3.9 and 8.0 mmol/L) was 37.96 +/- 6.81% for the NPH group and 35.83 +/- 6.240% for the glargine group. At endpoint, time in the euglycemic range increased in both groups (51.02 +/- 7.22% and 57.29 +/- 10.27%, P<0.001 vs. before treatment for both groups). Time spent in the hypoglycernic range (glucose <3.9 mmol/L) was 9.98 +/- 2.57% for the first group and 10.24 +/- 3.55% for the second group at baseline. At endpoint, time in the hypoglycernic range decreased in both groups (8.00 +/- 2.13% and 6.59 +/- 2.04%, P<0.001 vs. before treatment for both groups). CONCLUSION: The analysis of the GlucoDay data gave us information about glycemia other than HbA1c and self-monitoring of blood glucose, such us a peakless activity profile and the lower percentage of time spent in the hypoglycernic range in the glargine-treated group.
引用
收藏
页码:166 / 170
页数:5
相关论文
共 50 条
  • [21] Continuous glucose monitoring for intensive care patients using whole blood microdialysis
    F Feichtner
    R Schaller
    A Fercher
    L Schaupp
    J Plank
    A Wutte
    M Ellmerer
    T Pieber
    Critical Care, 11 (Suppl 2):
  • [22] Glycemia Assessed by Continuous Glucose Monitoring among Patients on Dialysis
    Mayeda, Laura
    Zelnick, Leila R.
    Trikudanathan, Subbulaxmi
    Hirsch, Irl B.
    Ashford, Nathaniel
    Hall, Yoshio N.
    De Boer, Ian
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2024, 35 (10):
  • [23] Continuous Glucose Monitoring System in Acromegalic Patients: Possible Role in the Assessment of Glycemia Control
    Mercuri, Valeria
    D'Amico, Tania
    Costa, Denise
    De Vito, Corrado
    D'Angelo, Luca
    Schiaffini, Riccardo
    Gargiulo, Patrizia
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (06): : 1346 - 1351
  • [24] VARIABILITY OF THE GLYCEMIA MEASURED BY CONTINUOUS GLUCOSE MONITORING IN HYPERTENSIVE PATIENTS
    Garcia Donaire, J.
    Rabanal Basalo, A.
    Laguna Calle, V.
    Barbero Pedraz, A.
    Abad Cardiel, M.
    Martell Claros, N.
    JOURNAL OF HYPERTENSION, 2015, 33 : E177 - E177
  • [25] Evaluation of microdialysis-based glucose monitoring in blood and subcutaneous adipose tissue in type 1 diabetic patients
    Mader, J. K.
    Feichtner, F.
    Korsatko, S.
    Koehler, G.
    Schaller, R.
    Plank, J.
    Pieber, T. R.
    Ellmerer, M.
    DIABETOLOGIA, 2008, 51 : S435 - S435
  • [26] Continuous glucose monitoring by intravenous microdialysis
    Rooyackers, O.
    Blixt, C.
    Mattsson, P.
    Wernerman, J.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2010, 54 (07) : 841 - 847
  • [27] The glucose area under the profiles obtained with continuous glucose monitoring system relationships with NbAlc in pediatric type-1 diabetic patients
    Salardi, S
    Zucchini, S
    Santoni, R
    Ragni, L
    Gualandi, S
    Cicognani, A
    Cacciari, E
    DIABETES CARE, 2002, 25 (10) : 1840 - 1844
  • [28] Accuracy of a Novel Continuous Glucose Monitoring System (CGMS) Using Intravenous (iv) Microdialysis
    Zijlstra, Eric
    Hartlep, Michael
    O'Connell, Mark
    Heise, Tim
    Kuennecke, Wolfgang
    DIABETES, 2010, 59 : A34 - A34
  • [29] CONTINUOUS GLUCOSE MONITORING IN GSD TYPE 1 PATIENTS
    Faria, A.
    Cardoso, R.
    Diogo, L.
    Garcia, P.
    MOLECULAR GENETICS AND METABOLISM, 2009, 98 (1-2) : 117 - 118
  • [30] Efficacy of continuous glucose monitoring system (CGMS) to detect postprandial hyperglycemia and unrecognized hypoglycemia in type 1 diabetic patients
    Maia, Frederico F. R.
    Araujo, Levimar R.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2007, 75 (01) : 30 - 34