Tendon graft substitutes-rotator cuff patches

被引:73
作者
Coons, David A.
Barber, F. Alan
机构
[1] Pacific Sports Med Multicare, Tacoma, WA USA
[2] Plano Orthoped & Sports Med Ctr, Plano, TX USA
关键词
rotator cuff tendon; GraftJacket; CuffPatch; restore; TissueMend; graft substitutes;
D O I
10.1097/00132585-200609000-00011
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Over the past few years, many biologic patches have been developed to augment repairs of large or complex tendon tears. These patches include both allograft and xenografts. Regardless of their origins, these products are primarily composed of purified type I collagen. Many factors should be considered when choosing an augmentation patch including tissue origin, graft processing, cross-linking, clinical experience, and physical properties. The purpose of this article is to familiarize the sports medicine community with several tendon augmentation grafts: GraftJacket (Wright Medical Technology, Arlington, TN), CuffPatch (Organogenesis, Canton, MA, licensed to Arthrotek, Warsaw, IN), Restore (Depuy, Warsaw, IN), Zimmer Collagen Repair (Permacol) patch (Tissue Science Laboratories Covington, GA, licensed to Zimmer, Warsaw, IN), TissueMend (TEI Biosciences, Boston, MA, licensed to Stryker Howmedica Osteonics, Kalamazoo, MI), OrthoADAPT (Pegasus Biologics, Irvine, CA), and BioBlanket (Kensey Nash, Exton, PA).
引用
收藏
页码:185 / 190
页数:6
相关论文
共 40 条
[1]  
Abraham GA, 2000, J BIOMED MATER RES, V51, P442, DOI 10.1002/1097-4636(20000905)51:3<442::AID-JBM19>3.3.CO
[2]  
2-W
[3]  
AIKEN SW, 1994, VET COMP ORTHOPAED, V7, P124
[4]   Naturally occurring extracellular matrix as a scaffold for musculoskeletal repair [J].
Badylak, S ;
Arnoczky, S ;
Plouhar, P ;
Haut, R ;
Mendenhall, V ;
Clarke, R ;
Horvath, C .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (367) :S333-S343
[5]   THE USE OF XENOGENEIC SMALL-INTESTINAL SUBMUCOSA AS A BIOMATERIAL FOR ACHILLES-TENDON REPAIR IN A DOG-MODEL [J].
BADYLAK, SF ;
TULLIUS, R ;
KOKINI, K ;
SHELBOURNE, KD ;
KLOOTWYK, T ;
VOYTIK, SL ;
KRAINE, MR ;
SIMMONS, C .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (08) :977-985
[6]  
Bakos D, 2000, Polim Med, V30, P57
[7]   Tendon augmentation grafts: Biomechanical failure loads and failure patterns [J].
Barber, F. Alan ;
Herbert, Morley A. ;
Coons, David A. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (05) :534-538
[8]   Sutures and suture anchors: Update 2003 [J].
Barber, FA ;
Herbert, MA ;
Richards, DP .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (09) :985-990
[9]   Adverse effect of porcine collagen interposition after trapeziectomy - A comparative study [J].
Belcher, HJCR ;
Zic, R .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2001, 26 (02) :159-164
[10]  
Beniker D, 2003, ORTHOPEDICS, V26, pS591