Development of chloride-induced corrosion in pre-cracked RC beams under sustained loading: Effect of load-induced cracks, concrete cover, and exposure conditions

被引:92
作者
Yu, Linwen [1 ,4 ]
Francois, Raoul [1 ]
Vu Hiep Dang [2 ]
L'Hostis, Valerie [3 ]
Gagne, Richard [4 ]
机构
[1] Univ Toulouse, UPS, INSA, LMDC, Toulouse, France
[2] Hanoi Architectural Univ, Fac Civil Engn, Hanoi, Vietnam
[3] CEA Saclay, CEA, DEN, DPC,SECR,Lab Etud Comportement Betons & Argiles, F-91191 Gif Sur Yvette, France
[4] Univ Sherbrooke, Quebec City, PQ, Canada
关键词
Corrosion; Chloride; Reinforcement; REINFORCEMENT CORROSION; STEEL; DIFFUSION; PERFORMANCE; INTERFACE; DAMAGE; WIDTH;
D O I
10.1016/j.cemconres.2014.10.007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper deals with corrosion initiation and propagation in pre-cracked reinforced concrete beams under sustained loading during exposure to a chloride environment. Specimen beams that were cast in 2010 were compared to specimens cast in 1984. The only differences between the two sets of beams were the casting direction in relation to tensile reinforcement and the exposure conditions in the salt-fog chamber. The cracking maps, corrosion maps, chloride profiles, and cross-sectional loss of one group of two beams cast in 2010 were studied and their calculated corrosion rates were compared to that of beams cast in 1984 in order to investigate the factors influencing the natural corrosion process. Experimental results show that, after rapid initiation of corrosion at the crack tip, the corrosion process practically halted and the time elapsing before corrosion resumed depended on the exposure conditions and cover depth. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:246 / 258
页数:13
相关论文
共 56 条
[1]  
ACI Committee 318, 2005, 318 ACI COMM
[2]   Factors controlling cracking of concrete affected by reinforcement corrosion [J].
Alonso, C ;
Andrade, C ;
Rodriguez, J ;
Diez, JM .
MATERIALS AND STRUCTURES, 1998, 31 (211) :435-441
[3]  
Angst U., 2010, 6 INT C CONCR SEV CO
[4]   Critical chloride content in reinforced concrete - A review [J].
Angst, Ueli ;
Elsener, Bernhard ;
Larsen, Claus K. ;
Vennesland, Oystein .
CEMENT AND CONCRETE RESEARCH, 2009, 39 (12) :1122-1138
[5]  
[Anonymous], 1994, MATER STRUCT, V27, P415
[6]  
[Anonymous], 1997, 8110 BS
[7]  
[Anonymous], 1997, DUR CONCR STRUCT CEB
[8]  
[Anonymous], 2012, FIB INT FE IN PRESS, V1FIB
[9]  
[Anonymous], 2004, DES CONCR STRUCT 1
[10]  
[Anonymous], AS36002009