Can Risk Stratification Based on Ultrasound Elastography of Background Liver Assist CEUS LI-RADS in the Diagnosis of HCC?

被引:3
作者
Li, Jiawu [1 ]
Ling, Wenwu [1 ]
Chen, Shuang [1 ]
Yang, Lulu [1 ]
Ma, Lin [1 ]
Lu, Qiang [1 ]
Luo, Yan [1 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Ultrasound, Chengdu, Peoples R China
基金
中国国家自然科学基金;
关键词
contrast-enhanced ultrasound; liver imaging reporting and data system; liver; hepatocellular carcinoma; ultrasound elastography; GUIDELINES;
D O I
10.3389/fonc.2021.662680
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective To explore whether risk stratification based on ultrasound elastography of liver background assists contrast-enhanced ultrasound liver imaging reporting and data system (CEUS LI-RADS) in diagnosing HCC. Materials and Methods In total, 304 patients with focal liver lesions (FLLs) confirmed by pathology underwent CEUS and ultrasound elastography were included in this retrospective study. Patients with chronic hepatitis B (CHB, n=193) and non-CHB (n=111) were stratified by four liver stiffness measurement (LSM) thresholds. A LI-RADS category was assigned to FLLs using CEUS LI-RADS v2017. The diagnostic performance was assessed with the AUC, sensitivity, specificity, PPV, and NPV. Results The mean background liver stiffness of HCC patients with CHB, HCC patients without CHB and non-HCC patients without CHB were 9.72 kPa, 8.23 kPa and 4.97 kPa, respectively. The AUC, sensitivity, specificity and PPV of CEUS LI-RADS for HCC in CHB patients with LSM >= 5.8 kPa, >= 6.8 kPa, >= 9.1 kPa, and >= 10.3 kPa were high, with corresponding values of 0.745 to 0.880, 94.2% to 95.3%, 81.3% to 85.7%, and 98.1% to 98.8%, respectively. Higher AUC and specificity for HCC was observed in non-CHB patients with LSM >= 9.1 kPa and >= 10.3 kPa compared to non-CHB patients with LSM >= 5.8 kPa and >= 6.8 kPa, with corresponding values of0.964/1.000 vs 0.590/0.580, and 100%/100% vs 60%/70%, respectively. Conclusion CEUS LI-RADS has a good diagnostic performance in CHB patients regardless of the background liver stiffness. Furthermore, CEUS LI-RADS can be applied for non-CHB patients with a LSM >= 9.1 kPa.
引用
收藏
页数:9
相关论文
共 26 条
[1]   Elastography Assessment of Liver Fibrosis: Society of Radiologists in Ultrasound Consensus Conference Statement [J].
Barr, Richard G. ;
Ferraioli, Giovanna ;
Palmeri, Mark L. ;
Goodman, Zachary D. ;
Garcia-Tsao, Guadalupe ;
Rubin, Jonathan ;
Garra, Brian ;
Myers, Robert P. ;
Wilson, Stephanie R. ;
Rubens, Deborah ;
Levine, Deborah .
RADIOLOGY, 2015, 276 (03) :845-861
[2]   Management of Hepatocellular Carcinoma: An Update [J].
Bruix, Jordi ;
Sherman, Morris .
HEPATOLOGY, 2011, 53 (03) :1020-1022
[3]   LI-RADS for MR Imaging Diagnosis of Hepatocellular Carcinoma: Performance of Major and Ancillary Features [J].
Cerny, Milena ;
Bergeron, Catherine ;
Billiard, Jean-Sebastien ;
Murphy-Lavallee, Jessica ;
Olivie, Damien ;
Berube, Joshua ;
Fan, Boyan ;
Castel, Helene ;
Turcotte, Simon ;
Perreault, Pierre ;
Chagnon, Miguel ;
Tang, An .
RADIOLOGY, 2018, 288 (01) :118-128
[4]   Cancer Statistics in China, 2015 [J].
Chen, Wanqing ;
Zheng, Rongshou ;
Baade, Peter D. ;
Zhang, Siwei ;
Zeng, Hongmei ;
Bray, Freddie ;
Jemal, Ahmedin ;
Yu, Xue Qin ;
He, Jie .
CA-A CANCER JOURNAL FOR CLINICIANS, 2016, 66 (02) :115-132
[5]   Liver Imaging Reporting and Data System with MR Imaging: Evaluation in Nodules 20 mm or Smaller Detected in Cirrhosis at Screening US [J].
Darnell, Anna ;
Forner, Alejandro ;
Rimola, Jordi ;
Reig, Maria ;
Garcia-Criado, Angeles ;
Ayuso, Carmen ;
Bruix, Jordi .
RADIOLOGY, 2015, 275 (03) :698-707
[6]   GUIDELINES AND GOOD CLINICAL PRACTICE RECOMMENDATIONS FOR CONTRAST-ENHANCED ULTRASOUND (CEUS) IN THE LIVER-UPDATE 2020 WFUMB IN COOPERATION WITH EFSUMB, AFSUMB, AIUM, AND FLAUS [J].
Dietrich, Christoph F. ;
Nolsoe, Christian Pallson ;
Barr, Richard G. ;
Berzigotti, Annalisa ;
Burns, Peter N. ;
Cantisani, Vito ;
Chammas, Maria Cristina ;
Chaubal, Nitin ;
Choi, Byung Ihn ;
Clevert, Dirk-Andre ;
Cui, Xinwu ;
Dong, Yi ;
D'Onofrio, Mirko ;
Fowlkes, J. Brian ;
Gilja, Odd Helge ;
Huang, Pintong ;
Ignee, Andre ;
Jenssen, Christian ;
Kono, Yuko ;
Kudo, Masatoshi ;
Lassau, Nathalie ;
Lee, Won Jae ;
Lee, Jae Young ;
Liang, Ping ;
Lim, Adrian ;
Lyshchik, Andrej ;
Meloni, Maria Franca ;
Correas, Jean Michel ;
Minami, Yasunori ;
Moriyasu, Fuminori ;
Nicolau, Carlos ;
Piscaglia, Fabio ;
Saftoiu, Adrian ;
Sidhu, Paul S. ;
Sporea, Ioan ;
Torzilli, Guido ;
Xie, Xiaoyan ;
Zheng, Rongqin .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (10) :2579-2604
[7]  
Dietrich CF, 2017, ULTRASCHALL MED, V38, pE16, DOI 10.1055/s-0043-103952
[8]  
Feher Janos, 2010, Orvosi Hetilap, V151, P933, DOI 10.1556/OH.2010.28900
[9]   WFUMB GUIDELINES AND RECOMMENDATIONS FOR CLINICAL USE OF ULTRASOUND ELASTOGRAPHY: PART 3: LIVER [J].
Ferraioli, Giovanna ;
Filice, Carlo ;
Castera, Laurent ;
Choi, Byung Ihn ;
Sporea, Ioan ;
Wilson, Stephanie R. ;
Cosgrove, David ;
Dietrich, Christoph F. ;
Amy, Dominique ;
Bamber, Jeffrey C. ;
Barr, Richard ;
Chou, Yi-Hong ;
Ding, Hong ;
Farrokh, Andre ;
Friedrich-Rust, Mireen ;
Hall, Timothy J. ;
Nakashima, Kazutaka ;
Nightingale, Kathryn R. ;
Palmeri, Mark L. ;
Schafer, Fritz ;
Shiina, Tsuyoshi ;
Suzuki, Shinichi ;
Kudo, Masatoshi .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (05) :1161-1179
[10]   Diagnostic Accuracy of CEUS LI-RADS for the Characterization of Liver Nodules 20 mm or Smaller in Patients at Risk for Hepatocellular Carcinoma [J].
Huang, Jia-Yan ;
Li, Jia-Wu ;
Lu, Qiang ;
Luo, Yan ;
Lin, Ling ;
Shi, Yu-Jun ;
Li, Tao ;
Liu, Ji-Bin ;
Lyshchik, Andrej .
RADIOLOGY, 2020, 294 (02) :329-339