Fretting wear behavior of calcium phosphate-mullite composites in dry and albumin-containing simulated body fluid conditions

被引:10
作者
Nath, Shekhar [1 ]
Ummethala, Raghunandan [1 ]
Basu, Bikramjit [1 ]
机构
[1] Indian Inst Technol, Lab Biomat Mat & Met Engn, Kanpur 208016, Uttar Pradesh, India
关键词
DIAMOND-LIKE CARBON; CO-CR-MO; REINFORCED HYDROXYAPATITE; BIOMEDICAL APPLICATIONS; IN-VIVO; TRIBOLOGICAL CHARACTERIZATION; MECHANICAL-PROPERTIES; ZIRCONIA COMPOSITES; DOPED ZIRCONIA; CERAMICS;
D O I
10.1007/s10856-009-3983-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In a recent work, it has been shown that it is possible to achieve a better combination of compressive strength, flexural strength and toughness properties in calcium phosphate (CaP) composites containing 20 and 30 wt% mullite (3Al(2)O(3)center dot 2SiO(2)). In view of their potential application as load bearing implants, the present work reports the friction and wear properties of the newly developed composites against zirconia under dry ambient as well as in simulated body fluid (SBF) containing bovine serum albumin (BSA) protein. For comparison, experiments were also conducted on monolithic hydroxyapatite (HAp, Ca-10(PO4)(6)(OH)(2)) and mullite under identical conditions. Under the investigated fretting conditions, the mullite-containing composites exhibited higher coefficient of friction (COF) of 0.4-0.6, compared to pure HAp (COF similar to 0.25-0.3). Although the wear resistance of the composites containing 20 or 30 wt% mullite was better in dry conditions, higher wear rate was measured in SBF conditions. The difference in tribological properties has been analyzed in reference to the difference in phase assemblage and mechanical properties. A comparison with some competing biomaterials reveals good potential of the investigated CaP-mullite composites for application as wear resistant implants.
引用
收藏
页码:1151 / 1161
页数:11
相关论文
共 6 条
  • [1] Wear Behavior of Plasma Oxidized CoCrMo Alloy under Dry and Simulated Body Fluid Conditions
    Ayhan Çelik
    Mevra Aslan
    Ali Fatih Yetim
    Özgü Bayrak
    Journal of Bionic Engineering, 2014, 11 : 303 - 310
  • [2] Wear Behavior of Plasma Oxidized CoCrMo Alloy under Dry and Simulated Body Fluid Conditions
    Celik, Ayhan
    Aslan, Mevra
    Yetim, Ali Fatih
    Bayrak, Ozgu
    JOURNAL OF BIONIC ENGINEERING, 2014, 11 (02) : 303 - 310
  • [3] Film Formation by Precipitating Calcium Phosphate on Phospholipid Vesicle in Simulated Body Fluid Containing Trometamol
    Yamaguchi, Tadashi
    Yamada, Iori
    Tagaya, Motohiro
    KOBUNSHI RONBUNSHU, 2018, 75 (01) : 32 - 41
  • [4] Preparation and characterization of calcium phosphate containing coating on plasma electrolytic oxidized magnesium and its corrosion behavior in simulated body fluids
    Zhang, Xue
    Cui, Shao-Dong
    Zhou, Lin
    Lian, Jing-Bao
    He, Jiao
    Li, Xiao-Wu
    JOURNAL OF ALLOYS AND COMPOUNDS, 2022, 896
  • [5] Creep, recovery, and stress relaxation behavior of nanostructured bioactive calcium phosphate glass-POSS/polymer composites for bone implants studied under simulated physiological conditions
    Belyamani, Imane
    Kim, Kyoungtae
    Rahimi, Shahab Kashani
    Sahukhal, Gyan S.
    Elasri, Mohamed O.
    Otaigbe, Joshua U.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2019, 107 (07) : 2419 - 2432
  • [6] In vitro degradation and dry sliding wear behaviour of AZ31-Sn/Al2O3 nano metal matrix composites in simulated body fluid for biomedical application
    Ajay, C. Veera
    Manisekar, K.
    Mohammed, K. Thoufiq
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART L-JOURNAL OF MATERIALS-DESIGN AND APPLICATIONS, 2024, 238 (01) : 148 - 159