Semi-automated 96-well solid-phase extraction and gas chromatography-negative chemical ionization tandem mass spectrometry for the trace analysis of fluprostenol in rat plasma

被引:5
|
作者
Gauw, RD [1 ]
Stoffolano, PJ [1 ]
Kuhlenbeck, DL [1 ]
Patel, VS [1 ]
Garver, SM [1 ]
Baker, TR [1 ]
Wehmeyer, KR [1 ]
机构
[1] Procter & Gamble Pharmaceut, Mason, OH 45040 USA
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 744卷 / 02期
关键词
fluprostenol;
D O I
10.1016/S0378-4347(00)00254-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Semi-automated 96-well plate solid-phase extraction (SPE) was used for sample preparation of fluprostenol, a prostaglandin analog, in rat plasma prior to detection by gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS-MS). A liquid handling system was utilized for all aspects of sample handling prior to SPE including transferring of samples into a 96-well format, preparation of standards as well as addition of internal standard to standards, quality control samples and study samples. SPE was performed in a 96-well plate format using octadecylsilane packing and the effluent from the SPE was dried in a custom-made 96-well apparatus. The sample residue was derivatized sequentially with pentafluorobenzylbromide followed by N-methyl-N-trimethylsilyltrifluoroacetamide. The derivatized sample was then analyzed using GC-NCI-MS-MS. The dynamic range for the method was from 7 to 5800 pg/ml with a 0.1-ml plasma sample. The methodology was evaluated over a 4-day period and demonstrated an accuracy of 90-106% with a precision of 2.4-12.9%. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:283 / 291
页数:9
相关论文
共 50 条
  • [31] Fully automated 96-well liquid-liquid extraction for analysis of biological samples by liquid chromatography with tandem mass spectrometry
    Peng, SX
    Branch, TM
    King, SL
    ANALYTICAL CHEMISTRY, 2001, 73 (03) : 708 - 714
  • [32] Determination of polychlorinated biphenyl congeners in human milk by gas chromatography-negative chemical ionization mass spectrometry after sample clean-up by solid-phase extraction
    Dmitrovic, J
    Chan, SC
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 778 (1-2): : 147 - 155
  • [33] Determination of 20 kinds of pesticide residues in soybeans and corn using gas chromatography-negative chemical ionization mass spectrometry coupled with offline disperse solid-phase extraction
    Li Chunfeng
    Shen Weijian
    Jiang Yuan
    Shen Chongyu
    Zhao Zengyun
    Yu Keyao
    Gui Qianwen
    Sun Ningning
    Yuan Zonghui
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2009, 27 (02) : 176 - 180
  • [34] DETERMINATION OF FLUMAZENIL IN PLASMA BY GAS CHROMATOGRAPHY-NEGATIVE ION CHEMICAL-IONIZATION MASS-SPECTROMETRY
    SONG, DM
    KHAYKIS, V
    KOHLHOF, K
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 663 (02): : 263 - 273
  • [35] Determination of the glucocorticoid fluticasone propionate in plasma by automated solid-phase extraction and liquid chromatography tandem mass spectrometry
    Callejas, SL
    Biddlecombe, RA
    Jones, AE
    Joyce, KB
    Pereira, AI
    Pleasance, S
    JOURNAL OF CHROMATOGRAPHY B, 1998, 718 (02): : 243 - 250
  • [36] Determination of 12 azole fungicide residues in beans and corn by offline disperse solid phase extraction and gas chromatography-negative chemical ionization mass spectrometry
    Shen Weijian
    Gui Qianwen
    Yu Keyao
    Sun Ningning
    Zhao Zengyun
    Shen Chongyu
    Wu Bin
    Jiang Yuan
    Chu Xiaogang
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2009, 27 (01) : 91 - 95
  • [37] Rapid gas chromatography/mass spectrometry quinine determination in plasma after automated solid-phase extraction
    Damien, Richard
    Daval, Sandrine
    Souweine, Bertrand
    Deteix, Patrice
    Eschalier, Alain
    Coudore, Francois
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (17) : 2528 - 2532
  • [38] A semi-automated 96-well plate method for the simultaneous determination of oral contraceptives concentrations in human plasma using ultra performance liquid chromatography coupled with tandem mass spectrometry
    Licea-Perez, Hermes
    Wang, Sherry
    Bowen, Chester L.
    Yang, Eric
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 69 - 76
  • [39] Trace level determination of trichloroethylene in biological samples by headspace solid-phase microextraction gas chromatography/negative chemical ionization mass spectrometry
    Liu, Yongzhen
    Muralidhara, Srinivasa
    Bruckner, James V.
    Bartlett, Michael G.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (06) : 797 - 806
  • [40] Gas chromatography/negative chemical ionization mass spectrometry of transfluthrin in rat plasma and brain
    Hooshfar, Shirin
    Mortuza, Tanzir B.
    Rogers, Clinton A.
    Linzey, Michael R.
    Gullick, Darren R.
    Bruckner, James V.
    White, Catherine A.
    Bartlett, Michael G.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (19) : 1573 - 1581